ETENWOLF S3 Cordless Tire Inflator Noise Test Report (Internal Standard, 1 m, Front-Face)

Document Overview

Key Findings All three S3 samples measured between 78.7 dB and 80.8 dB at 1 m front-face distance during continuous operation, falling within the evaluated sound-pressure range of 35–100 dB and recorded as for reference only per internal standard. Product: ETENWOLF S3 Cordless Tire Inflator…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Noise Testing

Key Findings

All three S3 samples measured between 78.7 dB and 80.8 dB at 1 m front-face distance during continuous operation, falling within the evaluated sound-pressure range of 35–100 dB and recorded as for reference only per internal standard.

  • Product: ETENWOLF S3 Cordless Tire Inflator
  • Report No.: 2025062901
  • Test Date: 2025-06-29
  • Samples: 3 units (7#, 8#, 9#)
  • Standard: Internal standard — sound pressure level (Lmax 35–100 dB)
  • Measurement distance: 1 m, microphone aligned horizontally with product front face
  • Result range: 78.7 dB – 80.8 dB
  • Verdict: For Reference Only

Test Overview

Field Detail
Test Type Noise Testing (Reliability Test)
Test Standard Internal Standard — Sound Pressure Level (Lmax 35–100 dB)
Report No. 2025062901
Test Date 2025-06-29
Product No./Name ETENWOLF S3 Cordless Tire Inflator
Model / Specification S3
Manufacturer ETENWOLF
Sample Quantity / No. 3 PCS
Test Purpose Evaluate the noise level of the sample under different operating scenarios
Test Environment Room Temperature 23 °C, Relative Humidity 60%

Test Equipment & Setup

Item Detail
Test Equipment Sound Level Meter (Noise Meter)
Measurement Distance 1 m — microphone placed at horizontal front-face distance from product
Microphone Orientation Front face of product
Operating State Product powered on and running
Evaluated Range Sound Pressure Level Lmax 35–100 dB
Ambient Temperature 23 °C
Relative Humidity 60%

Test Procedure

  1. Pre-test: Confirm ambient temperature (23 °C) and relative humidity (60%). Verify the sound level meter is calibrated and functional.
  2. Sample preparation: Label three S3 units as 7#, 8#, and 9#. Inspect each unit for any visible defects before testing.
  3. Microphone placement: Position the microphone at exactly 1 m horizontal distance from the front face of the product at the same height as the product.
  4. Operation: Power on the S3 unit. Allow the unit to reach normal operating state (inflation mode).
  5. Measurement: Record the sound pressure level (dB) displayed on the noise meter while the product is operating. Capture the Lmax reading.
  6. Repeat: Perform the same procedure for each of the three samples (7#, 8#, 9#) sequentially.
  7. Post-test: Power off all samples. Record all measurements and observations in the test data table.

Acceptance Criteria: Sound pressure level must fall within the evaluated range of Lmax 35–100 dB. Results are recorded for reference only per internal standard.

Test Data & Results

Sample No. Direction Distance from Microphone Noise (dB)
7# Front 1 m 80.8
8# Front 1 m 80.6
9# Front 1 m 78.7

Observations: All three samples produced consistent noise readings between 78.7 dB and 80.8 dB at 1 m front-face distance. Sample 9# recorded the lowest value at 78.7 dB; sample 7# recorded the highest at 80.8 dB. The spread across samples is 2.1 dB, indicating good unit-to-unit consistency. All readings fall within the defined evaluation range of 35–100 dB.

Conclusion

Parameter Detail
Evaluated Range Sound Pressure Level Lmax 35–100 dB
Measured Results 7#: 80.8 dB | 8#: 80.6 dB | 9#: 78.7 dB
Test Standard Internal Standard
Test Conditions 23 °C, 60% RH, 1 m front-face, product powered on
Samples Tested 3 PCS (7#, 8#, 9#)
Verdict For Reference Only (供参考)

Document Information

Role Name (Pinyin) Date
Tested By Li Guanghua 2025-06-29
Checked By Zhang Ronggui 2025-06-29
Approved By Mai Shaoqiang 2025-06-29
Field Detail
Source File S3充气泵-噪音测试 2025.6.29.xlsx
Sheet Name 噪音测试
Report No. 2025062901
Form Type Environmental Noise Test Report

Frequently Asked Questions

How loud is the ETENWOLF S3 tire inflator during operation?

In controlled testing at 1 m front-face distance, the S3 recorded between 78.7 dB and 80.8 dB across three units. This is comparable to a busy street or a vacuum cleaner, which is typical for a portable tire inflator operating at working pressure.

What test standard was used for the S3 noise test?

The test was conducted against ETENWOLF’s internal standard, which evaluates sound pressure level within a range of Lmax 35–100 dB. The test does not reference an external regulatory standard such as IEC or ISO for this specific measurement.

What does ‘For Reference Only’ mean in the S3 noise test verdict?

‘For Reference Only’ (供参考) indicates that the noise measurements are documented as informational data. The results confirm the S3 operates within the evaluated range but are not used as a pass/fail compliance determination against a mandatory external standard.

At what distance was the noise level of the S3 measured?

The microphone was positioned at exactly 1 m horizontal distance from the front face of the S3 unit while the product was powered on and operating normally. All three samples were measured under identical conditions at room temperature (23 °C) and 60% relative humidity.

Related Products