Document Overview
Document Overview This page presents the official RoHS test report for the ETENWOLF Air3 portable air pump, issued by Waltek Testing Group (Shenzhen) Co., Ltd. under Report No. WTH25X05129162C. The report was prepared in accordance with the EU RoHS Directive 2011/65/EU and its amending regulation…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- European Union: CE / RoHS / REACH / WEEE
Document Overview
This page presents the official RoHS test report for the ETENWOLF Air3 portable air pump, issued by Waltek Testing Group (Shenzhen) Co., Ltd. under Report No. WTH25X05129162C.
The report was prepared in accordance with the EU RoHS Directive 2011/65/EU and its amending regulation (EU) 2015/863, which restricts the use of ten hazardous substances in electrical and electronic equipment sold within the European Union.
| Field | Detail |
|---|---|
| Document Type | RoHS Test Report |
| Report Number | WTH25X05129162C |
| Issuing Laboratory | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Date of Issue | 2025-06-09 |
| Testing Period | 2025-05-28 to 2025-06-05 |
| Date of Sample Receipt | 2025-05-28 |
| Directive Scope | 10 restricted substances per EU RoHS 2011/65/EU & (EU) 2015/863 |
| Overall Conclusion | PASS |
Product Information
The tested product is the Air3, a portable air pump designed and distributed under the ETENWOLF brand. The applicant and manufacturer on record is Guangdong Bestek Technology Co., Ltd., located in Heyuan City, Guangdong, China.
| Field | Detail |
|---|---|
| Sample Name | Portable Air Pump |
| Model Number | Air3 |
| Reference Model No. | NA |
| Brand | NA (marketed under ETENWOLF) |
| Applicant | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China |
The Air3 is a compact, portable inflation tool intended for consumer and professional use. The RoHS evaluation covered 63 individual component parts spanning plastics, rubbers, metals, PCBs, electronic components, wiring, adhesives, and coatings.
Key Details
A total of 63 component parts from the Air3 were subjected to XRF primary screening followed by confirmatory chemical analysis where inconclusive (IN) XRF readings were detected. The table below summarises representative parts and their results.
| Part No. | Part Description | XRF Result | Pb (mg/kg) | Cd (mg/kg) | Hg (mg/kg) | Cr / Cr6+ | PBBs / PBDEs |
|---|---|---|---|---|---|---|---|
| 1 | Black plastic | BL/BL/BL/BL/IN | BL | BL | BL | BL | ND / ND |
| 15 | Silvery metal sheet ring | BL/BL/BL/IN | BL | BL | BL | Cr6+: Negative | NA |
| 17 | Silvery metal axle | BL/BL/BL/IN | BL | BL | BL | Cr6+: Negative | NA |
| 19 | Coppery metal ring | IN/BL/BL/BL | 2000# (exempted) | BL | BL | BL | NA |
| 27 | White cladding PCB board | BL/BL/BL/BL/IN | BL | BL | BL | BL | ND / ND |
| 40 | Silvery metal sheet (switch) | BL/BL/BL/IN | BL | BL | BL | Cr6+: Negative | NA |
| 42 | Silvery square metal body (switch) | BL/BL/BL/IN | BL | BL | BL | Cr6+: Negative | NA |
| 43 | Silvery metal shell | BL/BL/BL/IN | BL | BL | BL | Cr6+: Negative | NA |
| 47 | Black resistance SMD | BL/BL/BL/IN/BL | BL | BL | BL | Cr6+: ND | NA |
| 54 | Green cladding PCB board (whole) | BL/BL/BL/BL/IN | BL | BL | BL | BL | ND / ND |
Result key: BL = Below Limit | IN = Inconclusive (further chemical testing performed) | ND = Not Detected | NA = Not Applicable | # = value falls under an applicable RoHS exemption.
All parts where inconclusive XRF readings were recorded received confirmatory chemical analysis (ICP-OES, UV-Vis, or GC-MS). Every confirmatory result was either Negative or Not Detected, confirming compliance across all 63 parts.
Standards & Compliance
The testing programme for the Air3 was carried out against the following regulatory frameworks and analytical standards:
| Standard / Directive | Scope | Analytical Technique |
|---|---|---|
| EU RoHS Directive 2011/65/EU | Restriction of 10 hazardous substances in EEE | Regulatory basis |
| (EU) 2015/863 | Amendment adding four phthalates (DEHP, BBP, DBP, DIBP) | Regulatory basis |
| IEC 62321-3-1:2013 | XRF screening for Pb, Hg, Cd, total Cr, total Br | EDXRF |
| IEC 62321-4:2013+AMD1:2017 CSV | Mercury (Hg) determination | ICP-OES |
| IEC 62321-5:2013 | Lead (Pb) and Cadmium (Cd) determination | ICP-OES |
| IEC 62321-7-2:2017 and/or IEC 62321-7-1:2015 | Hexavalent chromium (Cr6+) determination | UV-Vis spectrophotometry |
| IEC 62321-6:2015 | Polybrominated biphenyls (PBBs) and diphenyl ethers (PBDEs) | GC-MS |
| IEC 62321-8:2017 | Phthalates (DEHP, BBP, DBP, DIBP) | GC-MS |
The XRF warning thresholds used for primary screening follow the concentration ranges defined in IEC 62321-3-1:2013. Where a component fell in the inconclusive (IN) range, confirmatory wet-chemistry analysis was mandatory before a pass or fail determination could be issued.
Validity & Certification Body
The test report was issued on 2025-06-09 by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory. The report is valid for the specific sample batch received on 2025-05-28.
| Field | Detail |
|---|---|
| Report Number | WTH25X05129162C |
| Date of Issue | 2025-06-09 |
| Testing Period | 2025-05-28 to 2025-06-05 |
| Laboratory | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Laboratory Address | 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China |
| Laboratory Website | http://www.waltek.com.cn |
| Contact Email | [email protected] |
| Telephone | +86-755-33663308 |
| Signed By | Hugo Chen, Waltek Testing Group (Shenzhen) Co., Ltd. |
| Validity Scope | Applies to submitted sample lot only; results do not automatically extend to other production batches |
As a third-party accredited laboratory, Waltek Testing Group provides independent verification that the Air3 meets all substance restrictions required for EU market access under the RoHS framework.
Frequently Asked Questions
- What does the RoHS PASS result mean for the Air3?
-
It means that all 63 tested component parts of the Air3 portable air pump contain restricted hazardous substances — including lead, mercury, cadmium, hexavalent chromium, PBBs, PBDEs, and the four regulated phthalates — at concentrations below the maximum limits set by EU RoHS Directive 2011/65/EU and its amendment (EU) 2015/863. The product is legally compliant for sale in the European Union.
- Why does part 19 (coppery metal ring) show a lead value of 2000 mg/kg yet the report still passes?
-
EU RoHS Directive 2011/65/EU includes specific exemptions for lead in certain applications, such as lead used in solders for high-reliability electrical connections or as an alloying element in copper alloys. The # symbol in the report indicates the detected lead concentration falls within an applicable exemption. The overall compliance conclusion therefore remains PASS.
- Which test methods were used to confirm the inconclusive XRF results?
-
Where XRF screening returned an inconclusive (IN) reading, confirmatory chemical testing was performed using ICP-OES (for Pb, Cd, Hg), UV-Vis spectrophotometry (for hexavalent chromium Cr6+), and GC-MS (for PBBs, PBDEs, and phthalates), all in accordance with the relevant IEC 62321 series standards. Every confirmatory result came back Negative or Not Detected.
- Does this RoHS report cover all substances restricted under the latest EU regulations?
-
Yes. The report scope explicitly includes all 10 substances restricted under EU RoHS 2011/65/EU as amended by (EU) 2015/863, which added the four phthalates DEHP, BBP, DBP, and DIBP to the original six substances (Pb, Hg, Cd, Cr6+, PBBs, PBDEs).
Related Documents
For full market compliance of the Air3 portable air pump, the RoHS test report is typically reviewed alongside the following complementary certification and compliance documents:
- CE Declaration of Conformity — confirms conformity with all applicable EU directives including the Low Voltage Directive (LVD) and Electromagnetic Compatibility (EMC) Directive required for CE marking in the European Economic Area.
- REACH SVHC Screening Report — assesses compliance with the REACH Regulation (EC) No 1907/2006 regarding Substances of Very High Concern (SVHCs) on the ECHA Candidate List.
- FCC Declaration of Conformity — required for the US market, confirming the Air3 meets FCC electromagnetic emission limits for consumer electronics.
- UN 38.3 Battery Transport Test Report — if the Air3 contains an integrated lithium battery, a UN 38.3 transport safety report is required for international shipping compliance.
- KC Certification — for the South Korean market, confirming conformity with Korean safety and EMC standards under the KC Mark scheme.
- ISO 9001 Quality Management Certificate — demonstrates that the manufacturing facility operates under a certified quality management system, supporting confidence in production consistency.