ETENWOLF S4 SUP Pump Noise Test Report (90 dB, Front-Face, 1 m)

Document Overview

Key Findings All three S4 SUP pump samples recorded sound pressure levels between 90.3 dB and 90.9 dB at 1 m front-face distance, falling within the evaluable range of the internal standard (Lmax 35–100 dB); results are provided for reference only. Product: S4 SUP Pump…

Document type
Certification Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Noise Testing

Key Findings

All three S4 SUP pump samples recorded sound pressure levels between 90.3 dB and 90.9 dB at 1 m front-face distance, falling within the evaluable range of the internal standard (Lmax 35–100 dB); results are provided for reference only.

  • Product: S4 SUP Pump (浆板泵)
  • Report No.: 2025081801
  • Test Date: 2025-08-18
  • Samples: 3 units
  • Measurement distance: 1 m, microphone level with product front face
  • Noise range: 90.3 dB – 90.9 dB
  • Verdict: For Reference Only

Test Overview

Field Details
Test Type Noise Testing (Reliability Test)
Test Standard Internal Standard — Sound Pressure Level Evaluation (Lmax 35–100 dB)
Report No. 2025081801
Test Date 2025-08-18
Product No./Name S4 SUP Pump (浆板泵)
Model / Specification S4
Manufacturer ETENWOLF
Sample Quantity / No. 3 PCS
Test Purpose Evaluate the noise level of the sample under different operating scenarios
Test Environment Room Temperature: 23 °C, Relative Humidity: 60%

Test Equipment & Setup

Item Details
Test Equipment Sound Level Meter (噪音计)
Microphone Position Horizontally level with the front face of the product
Measurement Distance 1 m from product front face
Measurement Direction Front face (正面)
Acceptance Criterion Sound pressure level Lmax: 35–100 dB
Ambient Temperature 23 °C
Relative Humidity 60%
Product State During Test Power-on, operating state

Test Procedure

  1. Pre-test: Confirm ambient conditions — temperature 23 °C, relative humidity 60%. Verify the sound level meter is calibrated and functional.
  2. Sample preparation: Label three S4 SUP pump units as 1#, 2#, and 3#. Place each sample on a stable surface in the test environment.
  3. Microphone placement: Position the microphone at a horizontal distance of 1 m from the front face of the product, at the same height as the product front face.
  4. Measurement: Power on the sample. Record the maximum sound pressure level (dB) displayed on the sound level meter while the product is running.
  5. Repeat: Perform the measurement for each of the three samples (#1, #2, #3) under identical conditions.
  6. Post-test: Power off each sample. Record all readings and environmental conditions. Compare results against the acceptance criterion (Lmax 35–100 dB).

Acceptance Criterion: Sound pressure level must fall within Lmax 35–100 dB for the result to be evaluable under the internal standard.

Test Data & Results

Sample No. Direction Distance from Microphone Noise (dB)
1# Front (正面) 1 m 90.9
2# Front (正面) 1 m 90.3
3# Front (正面) 1 m 90.9

Observations: All three samples produced consistent readings in the range of 90.3–90.9 dB at 1 m from the front face during normal operation. The spread across samples is 0.6 dB, indicating good unit-to-unit consistency. All values fall within the evaluable window of the internal standard (Lmax 35–100 dB).

Conclusion

Field Details
Result Range 90.3 dB – 90.9 dB
Standard Internal Standard — Lmax 35–100 dB
Test Conditions 23 °C, 60% RH, 1 m front-face distance, product powered on
Samples Tested 3 PCS (1#, 2#, 3#)
Verdict For Reference Only (供参考)

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-08-18
Checked By (审核/日期) Zhang Ronggui 2025-08-18
Approved By (核准/日期) Mai Shaoqiang 2025-08-18
Report No. 2025081801
Source File S4充浆泵-噪音测试 2025.8.18.xlsx

Frequently Asked Questions

How loud is the ETENWOLF S4 SUP pump during operation?

In controlled testing at 1 m from the front face, the S4 SUP pump measured between 90.3 dB and 90.9 dB across three samples. This is comparable to a motorcycle at close range and is expected for a high-pressure electric inflation pump running at full load.

What test standard was used for the S4 noise measurement?

The test used ETENWOLF’s internal standard, which evaluates sound pressure level within an Lmax range of 35–100 dB. The microphone was placed 1 m horizontally from the product front face while the unit was powered on and operating.

What does ‘For Reference Only’ mean in this noise test report?

‘For Reference Only’ (供参考) indicates that the test results are informational data points used for internal evaluation and product development. They are not a pass/fail certification against a published regulatory standard such as IEC or ISO.

How many samples were tested in the S4 noise evaluation?

Three production samples (1#, 2#, 3#) were tested under identical conditions — room temperature 23 °C, 60% relative humidity, and a fixed microphone distance of 1 m from the product front face. All three produced consistent readings within a 0.6 dB range.