CE-EMC Test Report WTH25H07183677E — ETENWOLF Vortex S6 Cordless Inflator

Document Overview

Document Overview This page presents the full CE Electromagnetic Compatibility (EMC) test report for the ETENWOLF Vortex S6 cordless inflator pump. The report was issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party electromagnetic compatibility laboratory located in Longgang District, Shenzhen, Guangdong,…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This page presents the full CE Electromagnetic Compatibility (EMC) test report for the ETENWOLF Vortex S6 cordless inflator pump. The report was issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party electromagnetic compatibility laboratory located in Longgang District, Shenzhen, Guangdong, China.

Field Detail
Document Type CE-EMC Test Report
Reference Number WTH25H07183677E
Test Report Form No. TRF EN IEC 55014-1: 2021-EMC-001-V01
Internal Form Reference HCT/RF-23-21
Issuing Laboratory Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Date of Sample Receipt 2025-07-11
Date of Testing 2025-07-15 to 2025-07-17
Date of Issue 2025-07-25
Overall Test Result Pass

The report covers conducted disturbance at mains terminals, disturbance power in the frequency range, and radiated disturbances, verifying that the product meets all applicable EMC limits required for CE marking in the European Economic Area.

Product Information

The Equipment Under Test (EUT) evaluated in this report is the ETENWOLF Vortex S6 heavy-duty cordless inflator pump, manufactured and supplied by Guangdong Bestek Technology Co., Ltd.

Field Detail
Product Name Inflator Pump
Model Number S6
Brand ETENWOLF
Applicant Guangdong Bestek Technology Co., Ltd.
Manufacturer Guangdong Bestek Technology Co., Ltd.
Applicant / Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China

The ETENWOLF Vortex S6 is a heavy-duty cordless inflator designed for inflating car tires, bicycle tires, sports equipment, and other inflatable items. As a motor-driven electrical appliance, it is subject to EMC requirements under the relevant European harmonised standards to ensure it does not cause harmful electromagnetic interference and maintains adequate immunity in its intended operating environment.

Key Details

The test report reference WTH25H07183677E covers three primary EMC test categories as defined by the applicable standards. The following table summarises each test module, the governing standard clause, and the recorded outcome.

Test Category Standard Reference Report Section Result
Conducted Disturbance at Mains Terminals EN IEC 55014-1: 2021 Section 3 Pass
Disturbance Power in the Frequency Range EN IEC 55014-1: 2021 Section 4 Pass
Radiated Disturbances EN IEC 55014-1: 2021 Section 5 Pass
Harmonic Current Emissions EN IEC 61000-3-2: 2019+A1:2021 Section 6 Pass
Voltage Fluctuations and Flicker EN 61000-3-3: 2013+A2:2021 Section 7 Pass

For each test category, the laboratory documented the measurement uncertainty, applicable limits, EUT setup configuration, instrument setup, test procedure, test equipment list, and detailed test data. The report spans 63 pages in total. Preparation was carried out by Snow Zeng and approved by Tony Wu at Waltek Testing Group HCT (Shenzhen) Co., Ltd.

Standards & Compliance

The ETENWOLF Vortex S6 was evaluated against the following harmonised European standards, which are cited in support of CE marking under the EMC Directive 2014/30/EU.

Standard Title / Scope Applicability
EN IEC 55014-1: 2021 Electromagnetic compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 1: Emission Conducted and radiated emission limits for motor-operated appliances
EN IEC 55014-2: 2021 Electromagnetic compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 2: Immunity Immunity requirements for motor-operated appliances
EN IEC 61000-3-2: 2019+A1:2021 Electromagnetic compatibility — Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) Harmonic current emissions at the mains port
EN 61000-3-3: 2013+A2:2021 Electromagnetic compatibility — Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems Voltage fluctuation and flicker limits

All four standards are harmonised under the EMC Directive and listed in the Official Journal of the European Union. A passing result against this standard suite is a prerequisite for affixing the CE mark and placing the product on the European market.

Validity & Certification Body

The test report was issued on 2025-07-25 and is valid as issued by the testing laboratory. Certification validity is subject to the applicant maintaining the product in the tested configuration. Any design, component, or manufacturing changes that could affect electromagnetic performance would require re-evaluation.

Field Detail
Issuing Laboratory Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Laboratory Address Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
Laboratory Website http://www.hct-test.com
Service Telephone 400-0066-989
Service Email [email protected]
Report Prepared By Snow Zeng
Report Approved By Tony Wu
Date of Issue 2025-07-25
Report Total Pages 63

Waltek Testing Group HCT is part of the Waltek Testing Group, a multinational testing, inspection, and certification organisation with laboratories accredited to international standards. The Shenzhen facility holds accreditation for EMC, safety, and radio testing relevant to CE, FCC, and other international market certifications.

Frequently Asked Questions

What does the CE-EMC test report WTH25H07183677E confirm about the ETENWOLF Vortex S6?

Report WTH25H07183677E confirms that the ETENWOLF Vortex S6 cordless inflator pump passed all electromagnetic compatibility emission and immunity tests required for CE marking. The tests were conducted at Waltek Testing Group HCT (Shenzhen) Co., Ltd. between 2025-07-15 and 2025-07-17, and the report was issued on 2025-07-25.

Which EMC standards were applied in testing the S6 inflator?

The S6 was tested against four harmonised European standards: EN IEC 55014-1: 2021 and EN IEC 55014-2: 2021 for emission and immunity of household appliances and electric tools, EN IEC 61000-3-2: 2019+A1:2021 for harmonic current emissions, and EN 61000-3-3: 2013+A2:2021 for voltage fluctuations and flicker.

Is the ETENWOLF Vortex S6 approved for sale in Europe?

The CE-EMC test report is one of the required technical documents supporting the CE Declaration of Conformity for the ETENWOLF Vortex S6. A passing EMC result, combined with the applicable safety certifications, allows the manufacturer to affix the CE mark and legally place the product on the European Economic Area market.

Who manufactured the S6 inflator and who conducted the EMC testing?

The ETENWOLF Vortex S6 is manufactured by Guangdong Bestek Technology Co., Ltd., located in Heyuan City, Guangdong, China. The EMC testing was independently conducted by Waltek Testing Group HCT (Shenzhen) Co., Ltd., a third-party accredited laboratory in Shenzhen, China.

Related Documents

The CE-EMC test report is one component of the full technical documentation package required for CE marking. The following related certification and compliance documents are relevant for the ETENWOLF Vortex S6 inflator pump.

  • CE-LVD (Low Voltage Directive) Test Report — Electrical safety evaluation under EN 62368-1 or EN 60335 series, required alongside EMC for full CE compliance of motor-driven appliances.
  • CE Declaration of Conformity (DoC) — The manufacturer’s formal declaration referencing all applicable directives and harmonised standards, required for CE marking.
  • FCC Test Report — Electromagnetic compatibility certification required for sale in the United States market, covering conducted and radiated emissions per FCC Part 15 or Part 18.
  • UN 38.3 Battery Transport Test Report — If the S6 includes a built-in lithium-ion battery, a UN 38.3 transport certification is required for international shipping compliance.
  • RoHS Compliance Report — Confirms the product and its components comply with EU RoHS Directive 2011/65/EU restrictions on hazardous substances.
  • REACH SVHC Declaration — Documents that substances of very high concern under the REACH Regulation (EC) No 1907/2006 are below threshold levels in the product.
  • KC Certification — Electromagnetic compatibility and safety certification required for the South Korean market under the KC mark scheme.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30
Document Page 31
Document Page 32
Document Page 33
Document Page 34
Document Page 35
Document Page 36
Document Page 37
Document Page 38
Document Page 39
Document Page 40
Document Page 41
Document Page 42
Document Page 43
Document Page 44
Document Page 45
Document Page 46
Document Page 47
Document Page 48
Document Page 49
Document Page 50
Document Page 51
Document Page 52
Document Page 53
Document Page 54
Document Page 55
Document Page 56
Document Page 57
Document Page 58
Document Page 59
Document Page 60
Document Page 61
Document Page 62
Document Page 63