UN38.3 Identification and Classification Report for ETENWOLF Air Inflator V3 Lithium-Ion Battery Pack

Document Overview

Document Overview This page presents the Identification and Classification Report for Transport of Goods issued by Beijing DGM Air Transport Technology Development Co., Ltd. (DGM China) for the ETENWOLF Air Inflator V3. The report determines whether the product is subject to dangerous-goods transport regulations under…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
International Transportation: CB / MSDS / UN38.3

Document Overview

This page presents the Identification and Classification Report for Transport of Goods issued by Beijing DGM Air Transport Technology Development Co., Ltd. (DGM China) for the ETENWOLF Air Inflator V3. The report determines whether the product is subject to dangerous-goods transport regulations under the UN Recommendations on the Transport of Dangerous Goods and the IMDG Code.

Field Detail
Report Number SEKSZ202506305077
Issued No. SEKSZ202506305077ZP640001
Document Type Identification and Classification Report (UN38.3)
Issuing Body Beijing DGM Air Transport Technology Development Co., Ltd.
Effective Date 2025-06-30
Identification Date 2025-06-30 to 2025-06-30
Identification Purpose Dangerous Goods or Not Restricted Identification
Identification Criteria IMDG CODE (Amendment 42-24)

Product Information

The subject of this report is the Air Inflator V3, a portable air inflator manufactured by Guangdong Bestek Technology Co., Ltd. for ETENWOLF. The unit contains a built-in lithium-ion battery pack whose specifications are detailed below.

Attribute Value
Product Name (English) Air Inflator V3
Battery Pack Included Lithium-ion Battery Pack 3S1P-2600
Battery Classification Li-ion Battery
Battery Type / Model 3S1P-2600
Nominal Voltage 11.1 V
Rated Capacity 2600 mAh
Watt-hour Rating 28.86 Wh
Mass 188.9 g
Lithium Content N/A (lithium-ion, no metallic lithium)
Appearance / Form Blue, prismatic
Cell Size 97.0 × 63.0 × 42.0 mm
Cells per Package 12 pieces
Configuration Contained in equipment
Applicant / Manufacturer Guangdong Bestek Technology Co., Ltd.
Manufacturer Address No. 1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China

Key Details

The following table reproduces the inspection checklist as recorded in the original report. Each item was evaluated against the applicable UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.8, Subsection 38.3 requirements.

Inspection Item Result
Watt-hour rating of the battery (28.86 Wh) Conform
Each battery type proved to meet all requirements of UN38.3 tests Conform
Batteries manufactured under a quality management programme Conform
Batteries are not returned-to-manufacturer, waste, or recycling/disposal batteries Conform
Each package capable of withstanding a 1.2 m drop test in any orientation Conform
Package marked according to Special Provision 188(1) Conform
Consignment accompanied by document indicating: contains Li-ion cells/batteries; handle with care / flammability hazard; special procedures if damaged; telephone number for information Not Applicable

Overall Conclusion: The Air Inflator V3 (containing lithium-ion battery pack 3S1P-2600 11.1V 2600mAh 28.86Wh) is classified as Not Subject to These Regulations. It is not restricted under IMDG CODE Special Provision 188 and may be shipped without dangerous-goods classification.

Standards & Compliance

The certification is based on the following international standards and test framework. All eight mandatory sub-tests of UN38.3 were conducted and passed.

Standard / Reference Description
UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.8, Section 38.3 Test requirements for lithium metal and lithium-ion batteries for transport
IMDG CODE Amendment 42-24, Special Provision 188 International Maritime Dangerous Goods Code — exemption provision for small lithium cells/batteries in equipment

The eight UN38.3 sub-tests and their results are summarised below.

Test Description Result
T.1 Altitude Simulation Pass
T.2 Thermal Test Pass
T.3 Vibration Pass
T.4 Shock Pass
T.5 External Short Circuit Pass
T.6 Impact / Crush Pass
T.7 Overcharge Pass
T.8 Forced Discharge Pass

Test laboratory: Waltek Testing Group Co., Ltd., No. 77 Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China. Website: www.waltek.com.cn.

Validity & Certification Body

This report is valid for one year from the date of issue (2025-06-30) in accordance with DGM China’s standard terms. The report is rendered invalid if it is illegally transferred, reproduced, embezzled, impersonated, modified, or tampered with in any media form.

Field Detail
Report Validity Period Within one year from 2025-06-30
Identification / Issuing Body Beijing DGM Air Transport Technology Development Co., Ltd.
DGM China Address 249, Haidian District, Beijing 101300, P.R. China
DGM China Tel 010-69479673
DGM China Fax 010-69479621
DGM China Email [email protected]
DGM China Website www.dgmchina.com.cn
Test Laboratory Waltek Testing Group Co., Ltd.
Test Lab Tel +86-769-2267 6998
Test Lab Email [email protected]
Applicant / Consignor Guangdong Bestek Technology Co., Ltd.
Applicant Tel 0762-3429081
Applicant Email [email protected]

Frequently Asked Questions

What does UN38.3 certification mean for the ETENWOLF Air Inflator V3?

UN38.3 is the internationally recognised battery safety standard under the UN Manual of Tests and Criteria. Passing all eight sub-tests (T.1–T.8) confirms that the lithium-ion battery pack inside the Air Inflator V3 is safe for transport by air, sea, and road. Report No. SEKSZ202506305077 documents this compliance.

Is the Air Inflator V3 classified as dangerous goods for shipping?

No. The report concludes that the product is Not Subject to These Regulations and is not restricted under IMDG CODE Special Provision 188. Because the battery pack’s watt-hour rating is 28.86 Wh — well below the 100 Wh threshold — it qualifies for the exemption and can be shipped without dangerous-goods classification.

How long is the UN38.3 report valid?

According to DGM China’s terms, this report is valid within one year from the effective date of 2025-06-30. After expiry, a new identification and classification report must be obtained for continued compliant transport.

Which test laboratory conducted the UN38.3 testing?

All physical battery tests were conducted by Waltek Testing Group Co., Ltd., an accredited test laboratory located in Dongguan City, Guangdong, China. The identification and classification report itself was issued by Beijing DGM Air Transport Technology Development Co., Ltd.

Related Documents

The following certification types are typically obtained alongside a UN38.3 report for a lithium-battery-powered product such as the Air Inflator V3. Obtaining this full suite of documents supports global market access and transport compliance.

  • IEC 62133 / UL 2054 — Battery safety standard for portable sealed secondary lithium cells and batteries; required for consumer electronics compliance in most markets.
  • CE Declaration of Conformity (LVD + EMC) — Mandatory for sale in the European Economic Area; covers electrical safety and electromagnetic compatibility.
  • FCC ID Certification — Required for the US market; covers radio-frequency emissions and intentional radiators if applicable.
  • KC Certification (KC Mark) — Required for the South Korean market under the Electrical Appliances and Consumer Products Safety Control Act.
  • RoHS / REACH Compliance Report — Confirms the product is free from restricted hazardous substances under EU RoHS Directive 2011/65/EU and REACH Regulation (EC) No 1907/2006.
  • MSDS / Safety Data Sheet — Material safety documentation for the lithium-ion battery pack, often required by freight forwarders and carriers.
  • IATA Dangerous Goods Declaration (if applicable) — Required when shipping lithium batteries by air in larger quantities beyond the Special Provision 188 exemption threshold.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6