Document Overview
Document Overview This page presents the official drop test report issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. (深圳市沃特虹彩检测技术有限公司) for the ETENWOLF S6 cordless inflator pump. The report documents a structured package drop test conducted in accordance with Chinese national standard GB/T 4857.5-1992 to…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Document Overview
This page presents the official drop test report issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. (深圳市沃特虹彩检测技术有限公司) for the ETENWOLF S6 cordless inflator pump. The report documents a structured package drop test conducted in accordance with Chinese national standard GB/T 4857.5-1992 to evaluate the product’s ability to withstand mechanical shock during transportation and handling.
- Report Number: WTH25H05125168P
- Document Type: Drop Test Report (跌落测试报告)
- Issuing Laboratory: Waltek Testing Group HCT (Shenzhen) Co., Ltd.
- Date of Issue: 2025-05-27
- Testing Period: 2025-05-19 to 2025-05-25
- Date of Sample Receipt: 2025-05-16
- Scope: Mechanical drop durability of the packaged inflator pump unit across 10 defined drop orientations at a height of 1000 mm
Product Information
The product evaluated in this report is the ETENWOLF Vortex S6 Heavy-Duty Cordless Inflator, a portable battery-powered inflation device designed for heavy-duty use with tires, inflatables, and other applications.
| Field | Detail |
|---|---|
| Product Name | Inflator Pump (充气泵) |
| Model Number | S6 |
| Sample ID Used in Test | S-01 |
| Sample Weight | 3.90 kg |
| Applicant | Guangdong Bestek Technology Co., LTD |
| Applicant Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
| Manufacturer | Guangdong Bestek Technology Co., LTD |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
Key Details
The drop test was carried out using a calibrated package drop testing machine (Model DT-325, Equipment No. WTHP1300A1-001, calibrated 2025-01-02, valid to 2026-01-01) and a calibrated electronic scale (Model XK3116, Equipment No. WTHP1180A1-001, calibrated 2024-07-31, valid to 2025-07-30). Ambient conditions during testing were 24.8 °C and 53.0% RH.
The test followed the sequential drop method defined in GB/T 4857.5-1992, covering all major corners, edges, and faces of the packaged product at a uniform drop height of 1000 mm. The full sequence is detailed below:
| Sequence | Drop Position | Drop Height | Sample Weight |
|---|---|---|---|
| 1 | Corner 2-3-5 | 1000 mm | 3.90 kg |
| 2 | Edge 2-5 | 1000 mm | 3.90 kg |
| 3 | Edge 3-5 | 1000 mm | 3.90 kg |
| 4 | Edge 2-3 | 1000 mm | 3.90 kg |
| 5 | Face 5 | 1000 mm | 3.90 kg |
| 6 | Face 6 | 1000 mm | 3.90 kg |
| 7 | Face 2 | 1000 mm | 3.90 kg |
| 8 | Face 4 | 1000 mm | 3.90 kg |
| 9 | Face 3 | 1000 mm | 3.90 kg |
| 10 | Face 1 | 1000 mm | 3.90 kg |
Test Result (Visual Inspection — Sample S-01): After completing all 10 drop sequences, the internal sample showed no damage, no deformation, no shedding, no loosening, and no cracking. Post-test functional verification confirmed that the startup function operated normally and the charging function operated normally. The ETENWOLF S6 passed all drop test requirements.
Standards & Compliance
The drop test was conducted in strict accordance with the following national standard:
| Standard | Title | Scope |
|---|---|---|
| GB/T 4857.5-1992 | Packaging — Basic Tests for Transport Packages — Drop Test Method | Defines the method for drop testing packaged products to simulate conditions encountered during distribution and transportation |
The standard specifies that a test is passed when the measured outcome meets or does not exceed the defined limit, regardless of measurement uncertainty. If a measured value exceeds the limit, the test is considered failed. All instruments used in this test are calibrated and traceable to national or international standards; further traceability information is available from the laboratory on request.
This report was prepared under the laboratory’s internal test report form reference TRFCHEN-SE-001-V01. Note that results in reports without a CMA logo are intended for the client’s internal quality control, product research and development, and scientific reference purposes, and do not constitute public proof of conformity.
Validity & Certification Body
The report was issued on 2025-05-27 and is valid as issued. Any dispute regarding the contents of this report must be submitted to the testing laboratory within 15 calendar days of receipt. Partial reproduction of this report is prohibited without written approval from Waltek Testing Group HCT (Shenzhen) Co., Ltd.
| Field | Detail |
|---|---|
| Laboratory Name | Waltek Testing Group HCT (Shenzhen) Co., Ltd. (深圳市沃特虹彩检测技术有限公司) |
| Laboratory Website | http://www.hct-test.com |
| Laboratory Address | Building B, Tianji Industrial Park, 1/F, 2/F & 3/F, No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China |
| Telephone | +86-0755-84616666 |
| [email protected] | |
| Tested by | 许东豪 / Daymon |
| Inspected by | 戚照刚 / Jeson Qi |
| Approved by | 黄庆盛 / Sem Huang |
| Report Form No. | TRFCHEN-SE-001-V01 |
| Report Pages | 7 pages |
Frequently Asked Questions
- What does the drop test report WTH25H05125168P confirm about the ETENWOLF S6?
- Report WTH25H05125168P confirms that the ETENWOLF S6 inflator pump successfully passed a 10-sequence drop test at 1000 mm height covering all critical corners, edges, and faces of the package. After all drops, the unit showed no physical damage, no deformation, no loosening, and all functions — startup and charging — operated normally.
- Which standard was used for the drop test, and what does it cover?
- The test was conducted according to GB/T 4857.5-1992, the Chinese national standard for package drop testing. It simulates the mechanical shocks a packaged product may experience during transportation and distribution by dropping it from a defined height onto a hard surface across multiple orientations.
- Who conducted the drop test for the S6 inflator pump?
- The test was conducted by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an established testing laboratory based in Shenzhen, Guangdong, China. The report was tested by Daymon (许东豪), inspected by Jeson Qi (戚照刚), and approved by Sem Huang (黄庆盛).
- Is this drop test report sufficient for customs, retail, or compliance submissions?
- This report was issued without a CMA (China Metrology Accreditation) logo, which means it is primarily intended for the client’s internal quality control, product development, and scientific reference purposes. For regulatory submissions, customs declarations, or retail compliance requirements that specifically require CMA- or CNAS-accredited results, please contact the manufacturer or laboratory for an appropriately accredited report version.
Related Documents
The following certification and compliance documents are commonly associated with a cordless inflator pump product such as the ETENWOLF S6 and are recommended for a complete compliance file:
- UN 38.3 Battery Transport Test Report — Required for air and ground shipment of lithium battery-powered devices; covers altitude simulation, thermal, vibration, shock, and short-circuit tests per UN 38.3.
- CE Declaration of Conformity — Mandatory for sale in the European Economic Area; typically covers Low Voltage Directive (LVD) and Electromagnetic Compatibility (EMC) Directive compliance per IEC standards.
- FCC Declaration of Conformity — Required for sale in the United States; covers electromagnetic emissions per FCC Part 15 regulations.
- RoHS Compliance Report — Confirms restriction of hazardous substances (lead, mercury, cadmium, etc.) in electrical and electronic equipment per RoHS Directive 2011/65/EU.
- REACH SVHC Declaration — Confirms the product does not contain Substances of Very High Concern above threshold limits per REACH Regulation (EC) No 1907/2006.
- KC Certification — Required for sale in South Korea; covers electrical safety and EMC requirements per KC standards.
- Vibration / Shock Test Report — Complements drop testing by evaluating sustained vibration resistance during transport, typically per ISO 2247 or ASTM D999.
- IP Rating (Ingress Protection) Test Report — Documents resistance to dust and water ingress per IEC 60529, relevant for a field-use cordless inflator.
Document Pages