Document Overview
Document Overview This page presents the official safety test report issued for the ETENWOLF Air3 portable inflator pump. The report was prepared by Shenzhen Waltek Testing Technology Co., Ltd. (深圳沃特检验技术有限公司), an accredited third-party testing laboratory, under a client-commissioned testing arrangement. Field Detail Report Number WTH25X04079173G…
- Document type
- User Manual
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- Compliance & Certification
Document Overview
This page presents the official safety test report issued for the ETENWOLF Air3 portable inflator pump. The report was prepared by Shenzhen Waltek Testing Technology Co., Ltd. (深圳沃特检验技术有限公司), an accredited third-party testing laboratory, under a client-commissioned testing arrangement.
| Field | Detail |
|---|---|
| Report Number | WTH25X04079173G |
| Document Type | Safety Test Report (检测报告) |
| Issuing Body | Shenzhen Waltek Testing Technology Co., Ltd. |
| Sample Receipt Date | 2025-04-01 |
| Test Period | 2025-04-01 to 2025-04-07 |
| Issue Date | 2025-04-07 |
| Template Number | WTX_GB4706_1_2005A |
| Overall Conclusion | All tested items comply with standard requirements. |
The scope of testing covers marking and instructions, input power and current, leakage current and electric strength at operating temperature, leakage current and electric strength after humidity conditioning, stability and mechanical hazards, mechanical strength, and construction requirements — all evaluated under GB4706.1-2005.
Product Information
The Air3 is a portable inflator pump (便携吹气泵) manufactured by Guangdong Bestark Technology Co., Ltd. (广东贝仕达克科技有限公司). It is designed as a compact, electronically controlled, Class III (SELV) appliance powered via a TYPE-C input port.
| Specification | Value |
|---|---|
| Product Name | Portable Inflator Pump (便携吹气泵) |
| Model | AIR3 |
| Rated Input Voltage | 5 V DC |
| Rated Input Current | 2 A |
| Power Supply Interface | TYPE-C Input: 5 V 2 A |
| Power Supply Type | DC (Direct Current) |
| Protection Class | Class III (SELV — Safety Extra-Low Voltage) |
| Ingress Protection Rating | IPX0 |
| Appliance Type | Portable |
| Control Type | Electronic circuit |
| Manufacturer | Guangdong Bestark Technology Co., Ltd. |
| Manufacturer Address | No. 1 North Gaopuba 8th Road, Industrial Park, Yuancheng District, Heyuan City, Guangdong, China |
| Country of Origin | Made in China |
| Sample Quantity Tested | 1 unit |
| Sample Condition | Intact |
The Air3 is not intended for permanent connection to fixed wiring. It operates exclusively on DC power supplied through its TYPE-C port, making it suitable for use with standard USB power adapters and power banks. A single model application was submitted with no variant models covered under this report.
Key Details
The following table summarises the clauses tested under GB4706.1-2005, the corresponding test requirements, and the results recorded for the Air3.
| Clause | Test Item | Result |
|---|---|---|
| 7 | Marking and Instructions | Pass |
| 7.1 | Rated voltage, power supply type, rated current, manufacturer name, model — all marked on nameplate | Pass |
| 7.6 | Correct use of symbols; units conform to international standards | Pass |
| 7.12 | Instructions provided with the appliance for safe use | Pass |
| 7.13 | Instructions provided in Simplified Chinese (official language of market) | Pass |
| 7.14 | Markings remain legible after 15-second wipe test with water and gasoline; label does not curl or detach | Pass |
| 7.15 | Markings located on main body; visible from outside without tools | Pass |
| 10 | Input Power and Current | Pass |
| 10.2 | Current deviation within permitted range at normal operating temperature (see appendix table) | Pass |
| 13 | Leakage Current and Electric Strength at Operating Temperature | Pass |
| 13.1 | Leakage current not excessive; supplied at 1.06× rated voltage | Pass |
| 13.2 | Leakage current measured via circuit described in IEC 60990 Figure 4 | Pass |
| 13.3 | Dielectric strength test — no breakdown occurred | Pass |
| 15.3 | Humidity conditioning: 48 hours at 25°C, 93% R.H. | Pass |
| 16 | Leakage Current and Electric Strength (post-humidity) | Pass |
| 16.2 | Test voltage 1.06× rated voltage (single-phase); leakage current measured | Pass |
| 16.3 | Dielectric strength test per Table 7 — no breakdown | Pass |
| 20 | Stability and Mechanical Hazards | Pass |
| 20.2 | Moving parts adequately guarded; protective enclosure mechanically robust and non-removable | Pass |
| 21 | Mechanical Strength | Pass |
| 21.1 | Impact test: 0.5 J energy applied three times to each enclosure section — no cracks or damage observed | Pass |
| 22 | Construction | Pass |
| 22.9 | Insulation not exposed to oil, grease, or similar substances | Pass |
| 22.11 | Non-removable parts providing protection against electric shock reliably secured | Pass |
| 22.13 | Operator’s hand cannot contact parts exceeding permitted temperature rise during normal use | Pass |
| 22.14 | No rough or sharp edges accessible to user during normal use or maintenance | Pass |
Test environment conditions: Ambient temperature 20 ± 5°C, Relative Humidity 60 ± 10% R.H. All measurements in appendix tables referenced within the full 21-page report.
Standards & Compliance
The Air3 was evaluated against the following Chinese national safety standard for household and similar electrical appliances:
| Standard | Title | Scope Applied |
|---|---|---|
| GB4706.1-2005 | Safety of Household and Similar Electrical Appliances — Part 1: General Requirements | Marking, input power, leakage current, electric strength, humidity, stability, mechanical strength, construction |
| IEC 60990 | Methods of Measurement of Touch Current and Protective Conductor Current | Figure 4 circuit used for leakage current measurement (Clauses 13.2, 16.2) |
| GB/T 4208 (equiv. IEC 60529) | Degrees of Protection Provided by Enclosures (IP Code) | IPX0 classification confirmed; no ingress protection testing required |
The testing clauses applied in this report are:
- Clause 7 — Marking and Instructions: nameplate content, symbols, user manual language, label durability
- Clause 10 — Input Power and Current: measured current deviation within standard limits
- Clause 13 — Leakage Current and Electric Strength at Operating Temperature: measured using IEC 60990 Figure 4 circuit
- Clause 16 — Leakage Current and Electric Strength (post-humidity): dielectric strength test per Table 7
- Clause 20 — Stability and Mechanical Hazards: moving part guarding, enclosure robustness
- Clause 21 — Mechanical Strength: 0.5 J impact energy, three strikes per section, no damage
- Clause 22 — Construction: insulation integrity, fastening of protective parts, user safety during handling
Clauses marked N/A in the test record indicate requirements not applicable to the Air3 based on its product classification (portable, Class III, IPX0, DC-powered, non-heating appliance).
Validity & Certification Body
This test report was issued by Shenzhen Waltek Testing Technology Co., Ltd. on 2025-04-07. The report is valid for the specific sample tested (1 unit, intact condition) under the stated test environment.
| Field | Detail |
|---|---|
| Report Number | WTH25X04079173G |
| Issue Date | 2025-04-07 |
| Testing Laboratory | Shenzhen Waltek Testing Technology Co., Ltd. (深圳沃特检验技术有限公司) |
| Laboratory Website | http://www.waltek.com.cn |
| Laboratory Address | 1F, Building 1 (Block A), Hongwei Industrial Park, Liuxian 2nd Road, Zone 70, Bao’an District, Shenzhen, Guangdong, China |
| Telephone | +86-755-33663308 |
| Fax | +86-755-33663309 |
| [email protected] | |
| Lead Tester (主检) | Ye Jintao (叶锦涛) |
| Reviewer (审核) | Gao Guanquan (高官权) |
| Approver (批准) | Wei Wenyong (韦文勇) |
| Test Type | Client-commissioned testing (委托检测) |
| Report Total Pages | 21 pages |
This report applies solely to the sample described and does not constitute product certification or regulatory approval. It documents compliance of the tested items with the specified clauses of GB4706.1-2005 as of the test date. Users requiring ongoing regulatory compliance should arrange periodic retesting, particularly following any design or component changes to the Air3.
Frequently Asked Questions
- What does the GB4706.1-2005 test report for the Air3 confirm?
- The report (No. WTH25X04079173G) confirms that the Air3 portable inflator passed all applicable safety tests under GB4706.1-2005, China’s national standard for household and similar electrical appliances. The tested items include marking and labelling, input current, leakage current, electric strength, mechanical strength, and construction requirements. All results were found to comply with the standard.
- What is the power input specification of the Air3?
- The Air3 is powered via a TYPE-C input port at 5 V DC, 2 A. It is a Class III appliance operating on safety extra-low voltage (SELV), meaning it does not require mains connection and poses a lower risk of electric shock compared to Class I or Class II appliances.
- Which testing laboratory issued this report and is it accredited?
- The report was issued by Shenzhen Waltek Testing Technology Co., Ltd. (深圳沃特检验技术有限公司), a professional third-party testing laboratory based in Shenzhen, China. The report was reviewed and approved by qualified personnel (lead tester, reviewer, and approver) and is traceable via report number WTH25X04079173G issued on 2025-04-07.
- Does the Air3 require any waterproofing or ingress protection rating?
- No. The Air3 is classified as IPX0, meaning no specific ingress protection against water is provided or required for its intended use. Waterproofing-related clauses (15.1.1, 15.1.2, 15.2) were therefore not applicable and were marked accordingly in the test report.
Related Documents
The following certification and compliance documents are typically relevant for a portable DC-powered inflator such as the Air3 and may accompany or complement this GB4706.1-2005 safety test report:
- UN 38.3 Battery Transport Test Report — Required if the Air3 is shipped with or contains a lithium battery; covers altitude simulation, thermal, vibration, shock, external short circuit, impact, overcharge, and forced discharge tests per UN 38.3.
- CE Declaration of Conformity (DoC) — Required for sale within the European Economic Area; covers Low Voltage Directive (LVD), EMC Directive, and RoHS Directive compliance for portable electronic appliances.
- FCC Declaration of Conformity or FCC ID Certificate — Required for the US market; covers unintentional radiator requirements under FCC Part 15 for electronic devices containing DC motors or switching circuits.
- RoHS Compliance Report — Confirms restriction of hazardous substances (lead, mercury, cadmium, hexavalent chromium, PBB, PBDE) in accordance with RoHS Directive 2011/65/EU and China RoHS (SJ/T 11364).
- REACH SVHC Declaration — Documents compliance with REACH Regulation (EC) No 1907/2006 regarding substances of very high concern in product materials.
- KC Certification — Required for the South Korean market; covers electrical safety and EMC requirements under KC Mark regulations administered by the National Radio Research Agency (RRA).
- EMC Test Report — Electromagnetic compatibility testing to confirm the Air3 does not cause or suffer from electromagnetic interference, typically conducted alongside safety testing for market approvals.