ETENWOLF X5PRO Tire Inflator Temperature Rise Test Report (Continuous Operation, Multi-Channel DAQ970A Logging)

Document Overview

Key Findings ETENWOLF X5PRO Tire Inflator completed a continuous temperature-rise logging run. The highest recorded channel value was 95.71 °C (Channel 5). The page presents engineering statistics and representative checkpoints instead of reproducing every acquisition row. Source workbook: X5充气泵-温升报告-2025.9.19.xls Recorded scans: 2,457 Monitored numeric channels:…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Environmental Testing

Key Findings

ETENWOLF X5PRO Tire Inflator completed a continuous temperature-rise logging run. The highest recorded channel value was 95.71 °C (Channel 5). The page presents engineering statistics and representative checkpoints instead of reproducing every acquisition row.

  • Source workbook: X5充气泵-温升报告-2025.9.19.xls
  • Recorded scans: 2,457
  • Monitored numeric channels: 13
  • Source sheet: 温升变化数据

Test Overview

Field Value
Product ETENWOLF X5PRO Tire Inflator
Test type Continuous temperature-rise data acquisition
Instrument Keysight DAQ970A (as identified in the source workbook)
Data treatment Channel statistics plus evenly spaced representative scans
Raw-data authority Original Excel workbook

Test Method

  1. Operate the product under the load and setup defined by the companion test-report sheet.
  2. Log the ambient reference and component temperature channels continuously.
  3. Review start, peak, end and stabilization behavior for every numeric channel.
  4. Retain the workbook as the authoritative interval-by-interval record.

Test Data & Results

Channel Summary

Channel Start °C Peak °C Peak scan End °C
Channel 1 25.57 26.72 2453 26.69
X5-8# 27.41 64.89 189 33.01
Channel 3 27.45 53.29 137 34.29
Channel 4 27.38 66.45 168 32.44
Channel 5 27.36 95.71 140 31.50
Channel 6 27.32 76.88 2456 76.83
Channel 7 27.38 80.60 2445 80.60
X5-9# 27.49 58.61 188 33.43
Channel 9 27.47 44.92 153 34.58
Channel 10 27.46 62.30 167 33.03
Channel 11 27.24 87.55 139 31.73
Channel 12 27.30 64.56 2457 64.56
Channel 13 27.38 78.60 2457 78.60

Representative Checkpoints

Scan Channel 1 X5-8# Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 X5-9#
1 25.57 27.41 27.45 27.38 27.36 27.32 27.38 27.49
615 24.82 45.31 41.02 43.58 40.93 38.25 36.47 41.57
1229 24.23 35.06 34.59 34.31 32.88 74.92 76.74 34.83
1843 24.53 33.59 34.66 32.99 31.64 75.61 77.31 33.96
2457 26.69 33.01 34.29 32.44 31.50 76.83 80.60 33.43

Data coverage note: The original sheet contains 2,457 acquisition rows. This web article intentionally condenses the series to channel-level statistics and representative checkpoints; no unreported value is inferred or fabricated.

Conclusion

This article reports the measured thermal profile without introducing a pass/fail threshold that is not present in the source data. Any formal compliance decision must be taken from the signed report sheet and its stated acceptance criteria.

Frequently Asked Questions

Why is the complete scan log not displayed?

The raw log is too long for a usable web page. Start, peak and end values are retained for every numeric channel, with representative checkpoints showing the progression.

Was any missing measurement estimated?

No. Blank or non-numeric source cells are shown as unavailable and are never interpolated.