ETENWOLF S4 SUP Pump Temperature Rise Test Report (Continuous Run, Dual-Unit Monitoring)

Document Overview

Key Findings ETENWOLF S4 SUP Pump completed a continuous temperature-rise logging run. The highest recorded channel value was 62.96 °C (S4-2#). The page presents engineering statistics and representative checkpoints instead of reproducing every acquisition row. Source workbook: S4浆板泵-温升报告-2025.8.19.xls Recorded scans: 233 Monitored numeric channels: 5…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Environmental Testing

Key Findings

ETENWOLF S4 SUP Pump completed a continuous temperature-rise logging run. The highest recorded channel value was 62.96 °C (S4-2#). The page presents engineering statistics and representative checkpoints instead of reproducing every acquisition row.

  • Source workbook: S4浆板泵-温升报告-2025.8.19.xls
  • Recorded scans: 233
  • Monitored numeric channels: 5
  • Source sheet: 温升变化数据

Test Overview

Field Value
Product ETENWOLF S4 SUP Pump
Test type Continuous temperature-rise data acquisition
Instrument Keysight DAQ970A (as identified in the source workbook)
Data treatment Channel statistics plus evenly spaced representative scans
Raw-data authority Original Excel workbook

Test Method

  1. Operate the product under the load and setup defined by the companion test-report sheet.
  2. Log the ambient reference and component temperature channels continuously.
  3. Review start, peak, end and stabilization behavior for every numeric channel.
  4. Retain the workbook as the authoritative interval-by-interval record.

Test Data & Results

Channel Summary

Channel Start °C Peak °C Peak scan End °C
Channel 1 25.42 26.16 151 25.50
S4-2# 26.82 62.96 223 59.62
Channel 3 26.06 53.46 233 53.46
S4-3# 26.09 61.78 212 55.73
Channel 5 26.49 56.86 217 55.86

Representative Checkpoints

Scan Channel 1 S4-2# Channel 3 S4-3# Channel 5
1 25.42 26.82 26.06 26.09 26.49
59 25.42 50.10 40.19 44.63 40.57
117 25.73 53.23 46.18 50.14 48.90
175 25.50 50.67 48.98 52.95 53.13
233 25.50 59.62 53.46 55.73 55.86

Data coverage note: The original sheet contains 233 acquisition rows. This web article intentionally condenses the series to channel-level statistics and representative checkpoints; no unreported value is inferred or fabricated.

Conclusion

This article reports the measured thermal profile without introducing a pass/fail threshold that is not present in the source data. Any formal compliance decision must be taken from the signed report sheet and its stated acceptance criteria.

Frequently Asked Questions

Why is the complete scan log not displayed?

The raw log is too long for a usable web page. Start, peak and end values are retained for every numeric channel, with representative checkpoints showing the progression.

Was any missing measurement estimated?

No. Blank or non-numeric source cells are shown as unavailable and are never interpolated.