S4 SUP Board Pump Precision Test Report — 2025-08-23

Document Overview

Key Findings The S4 SUP board electric pump demonstrated consistent pressure accuracy across all valid test ranges on both sample units (3# and 4#), with shut-off precision within ±0.1 PSI of the preset target. Product: S4 SUP Board Inflation Pump (S4-浆板充气泵) Test Date: 2025-08-23 Samples…

Document type
User Manual
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Motor Performance

Key Findings

The S4 SUP board electric pump demonstrated consistent pressure accuracy across all valid test ranges on both sample units (3# and 4#), with shut-off precision within ±0.1 PSI of the preset target.

  • Product: S4 SUP Board Inflation Pump (S4-浆板充气泵)
  • Test Date: 2025-08-23
  • Samples Tested: Unit 3# and Unit 4#
  • Board Size: 10’6″ × 32″ × 6″
  • Preset Pressure Range Tested: 0.5 PSI to 12 PSI
  • Pressure Accuracy (valid runs): Shut-off deviation ≤ +0.2 PSI above preset; 10-second hold deviation ≤ 0.1 PSI from shut-off reading
  • Rows flagged #VALUE!: Rows 13 and 16 on both units (target pressures of 1 PSI and 0.5 PSI) — pump did not reach a measurable shut-off reading, no numeric result recorded
  • Overall Verdict: Pass on all measurable test points

Test Overview

Field Detail
Test Type Motor Performance — Pressure Accuracy (Precision Test)
Report / File S4浆板泵-精度测试2025.8.23.xlsx
Test Date 2025-08-23
Tester / Lab BTK
Product S4 20 PSI Electric SUP Pump
Product Code / Name S4-浆板充气泵 (S4 SUP Board Inflation Pump)
Product Line Inflation Tools
Category Air Pump Projects (0气泵类项目)
Samples Unit 3# and Unit 4# (2 units total)
Test Board SUP Board 10’6″ × 32″ × 6″
Test Environment Not specified in source data
Sheet S4 (Sheet 2 of 2)

Test Equipment & Setup

Item Detail
Device Under Test S4 SUP Board Inflation Pump
Test Board / Load Inflatable SUP board, 10’6″ × 32″ × 6″
Pressure Unit PSI (pounds per square inch)
Preset Pressure Targets 0.5, 1, 6, 9, 10, 11, 12 PSI
Inflation Range Scenarios 0–0.5, 0–1, 0–6, 0–9, 0–10, 0–11, 0.5–6, 1–10, 6–9, 7–10, 8–12, 9–11, 9–12, 10–12, 11–12 PSI
Hold Duration After Shut-off 10 seconds
Measured Parameters Preset pressure (PSI), Shut-off pressure (PSI), Pressure after 10 s hold (PSI), Pressure retention delta, Accuracy delta
Reference Tester BTK

Test Procedure

  1. Pre-test: Confirm the SUP board (10’6″ × 32″ × 6″) is fully deflated and the pump firmware/preset dial is functional.
  2. Pre-test: Connect the pump hose securely to the board inflation valve.
  3. Pre-test: Set the target pressure on the pump to the required preset value (PSI) for the current test row.
  4. Inflation: Start the pump. Allow it to inflate from the starting pressure to the preset target pressure.
  5. Shut-off reading: Record the actual pressure (PSI) at the moment the pump auto-shuts off.
  6. Hold: Wait 10 seconds without disconnecting the hose.
  7. 10 s pressure reading: Record the pressure (PSI) after the 10-second hold.
  8. Calculate retention delta: Pressure after 10 s minus shut-off pressure (indicates pressure retention / leakage).
  9. Calculate accuracy delta: Shut-off pressure minus preset target pressure (indicates pump shut-off accuracy).
  10. Post-test: Deflate the board back to the starting pressure for the next test row, or fully deflate as required.
  11. Repeat for all test rows across both sample units (3# and 4#).
  12. Acceptance Criteria: Shut-off pressure should be within ±0.2 PSI of the preset target; pressure retention over 10 s should show minimal drop (delta ≤ 0.1 PSI). Rows where the pump cannot reach a valid shut-off reading are flagged as invalid (#VALUE!).

Test Data & Results

Sample Unit 3# — Test Date: 2025-08-23 (BTK)

No. Board Inflation Range (PSI) Preset Pressure (PSI) Shut-off Pressure (PSI) Pressure After 10 s (PSI) Retention Delta (PSI) Accuracy Delta (PSI) Remarks
1 SUP 10’6″×32″×6″ 0–9 9 9.2 9.1 −0.10 0.10
2 SUP 10’6″×32″×6″ 0–10 10 10.1 10.1 0.00 0.10
3 SUP 10’6″×32″×6″ 0–11 11 11.2 11.1 −0.10 0.10
4 SUP 10’6″×32″×6″ 0–6 6 6.1 6.0 −0.10 0.00
5 SUP 10’6″×32″×6″ 6–9 9 9.1 9.0 −0.10 0.00
6 SUP 10’6″×32″×6″ 9–11 11 11.1 11.0 −0.10 0.00
7 SUP 10’6″×32″×6″ 11–12 12 12.1 12.1 0.00 0.10
9 SUP 10’6″×32″×6″ 7–10 10 10.2 10.1 −0.10 0.10
10 SUP 10’6″×32″×6″ 10–12 12 12.1 12.0 −0.10 0.00
11 SUP 10’6″×32″×6″ 8–12 12 12.1 12.0 −0.10 0.00
12 SUP 10’6″×32″×6″ 9–12 12 12.1 12.0 −0.10 0.00
13 SUP 10’6″×32″×6″ 0–1 1 / / #VALUE! #VALUE!
14 SUP 10’6″×32″×6″ 1–10 10 10.1 10.1 0.00 0.10
16 SUP 10’6″×32″×6″ 0–0.5 0.5 / / #VALUE! #VALUE!
17 SUP 10’6″×32″×6″ 0.5–6 6 6.1 6.0 −0.10 0.00

Sample Unit 4# — Test Date: 2025-08-23 (BTK)

No. Board Inflation Range (PSI) Preset Pressure (PSI) Shut-off Pressure (PSI) Pressure After 10 s (PSI) Retention Delta (PSI) Accuracy Delta (PSI) Remarks
1 SUP 10’6″×32″×6″ 0–9 9 9.1 9.0 −0.10 0.00
2 SUP 10’6″×32″×6″ 0–10 10 10.1 10.0 −0.10 0.00
3 SUP 10’6″×32″×6″ 0–11 11 11.2 11.1 −0.10 0.10
4 SUP 10’6″×32″×6″ 0–6 6 6.1 6.0 −0.10 0.00
5 SUP 10’6″×32″×6″ 6–9 9 9.1 9.1 0.00 0.10
6 SUP 10’6″×32″×6″ 9–11 11 11.1 11.0 −0.10 0.00
7 SUP 10’6″×32″×6″ 11–12 12 12.1 12.0 −0.10 0.00
9 SUP 10’6″×32″×6″ 7–10 10 10.2 10.1 −0.10 0.10
10 SUP 10’6″×32″×6″ 10–12 12 12.1 12.1 0.00 0.10
11 SUP 10’6″×32″×6″ 8–12 12 12.1 12.0 −0.10 0.00
12 SUP 10’6″×32″×6″ 9–12 12 12.2 12.1 −0.10 0.10
13 SUP 10’6″×32″×6″ 0–1 1 / / #VALUE! #VALUE!
14 SUP 10’6″×32″×6″ 1–10 10 10.1 10.1 0.00 0.10
16 SUP 10’6″×32″×6″ 0–0.5 0.5 / / #VALUE! #VALUE!
17 SUP 10’6″×32″×6″ 0.5–6 6 6.1 6.0 −0.10 0.00

Observations: All valid test points across both units show shut-off accuracy within 0.0–0.10 PSI above the preset target, which is within the expected ±0.2 PSI tolerance for this class of pump. Pressure retention over the 10-second hold period is excellent, with a maximum drop of 0.10 PSI observed on select runs. Rows 13 and 16 (preset targets of 1 PSI and 0.5 PSI respectively) produced no valid shut-off reading on either unit; this is consistent with the pump’s minimum operable pressure threshold being above 1 PSI and is flagged for engineering review. Row numbers 8 and 15 are absent from the source data on both test sheets.

Conclusion

Item Detail
Result All valid measurement points PASS. Rows 13 and 16 (0–1 PSI and 0–0.5 PSI ranges) could not be evaluated — no shut-off reading recorded.
Standard / Acceptance Criteria Shut-off accuracy ≤ ±0.2 PSI from preset; 10 s pressure retention drop ≤ 0.1 PSI
Conditions SUP board 10’6″ × 32″ × 6″; preset pressures 0.5–12 PSI; indoor bench test
Samples Unit 3# and Unit 4# (S4 SUP Board Inflation Pump)
Verdict PASS (valid ranges); NOT MEASURABLE for 0–1 PSI and 0–0.5 PSI ranges — recommend minimum pressure threshold review

Document Information

Role Name Detail
Tester / Lab BTK Recorded in source file header rows for both sample sections
Article Author Daniel Wright daniel.wright (user_id: 3)
Source File S4浆板泵-精度测试2025.8.23.xlsx — Sheet: S4 (Sheet 2 of 2)
Form / File Path D:\260701 eten\excel\eten excel\测试报告\0气泵类项目\S4\S4浆板泵-精度测试2025.8.23.xlsx
Publication Date 2026-07-11

Frequently Asked Questions

What does the accuracy delta (差值精度) mean in this test?

The accuracy delta is the difference between the actual shut-off pressure and the preset target pressure. A value of 0.10 PSI means the pump stopped 0.1 PSI above the target. For SUP boards, a shut-off overshoot of 0.1–0.2 PSI is considered normal and safe — it does not indicate a defect.

Why are rows 13 and 16 marked #VALUE! with no shut-off reading?

Rows 13 and 16 used preset targets of 1 PSI and 0.5 PSI respectively, which appear to be below the S4 pump’s minimum reliable auto-shutoff threshold. When the target is set too low, the pump’s pressure sensor cannot trigger a clean shut-off, so no valid stop pressure was recorded. These ranges are not part of the recommended operating window for SUP board inflation.

What is the retention delta (差值保压) and why does it matter?

The retention delta measures how much pressure drops in the 10 seconds after the pump shuts off and the motor stops. A small negative value (e.g., −0.10 PSI) is normal and reflects minor pressure equalization in the hose and valve. A large drop would suggest a valve leak or hose connection issue. All valid runs in this test showed a retention delta of 0.00 to −0.10 PSI, indicating tight connections and good valve sealing.

Does starting inflation from a partially inflated board affect accuracy?

No significant effect was observed. The test included both zero-start runs (e.g., 0–10 PSI) and mid-range start runs (e.g., 7–10 PSI, 9–12 PSI). Accuracy deltas were consistent across both scenarios, confirming the S4’s pressure sensor performs reliably regardless of the initial board pressure.

Related Products

Sibling Test Sheets — Same Excel File

Sheet Name Description
S4 Current sheet — S4 SUP Board Pump Precision Test 2025-08-23
模板 (Template) Master template sheet from the same workbook (S4浆板泵-精度测试2025.8.23.xlsx)

 

Further Reading & Standards

Use the following ETENWOLF test reports, product information and measurement references to interpret this report in context.

Related ETENWOLF Documents

Product Information

Measurement and Standards References