ETENWOLF HB2 Hair Dryer Transport Vibration Test Report (ISTA-2A, 2025-04-19)

Document Overview

Key Findings All three HB2 hair dryer samples passed the ISTA-2A random vibration test, demonstrating stable performance with no abnormalities in appearance or charging function after 1 hour of multi-axis vibration exposure. Product: HB2 Hair Dryer (HB2-吹风机) Standard: ISTA-2A Test Mode: Random vibration, X/Y/Z axes…

Document type
Test Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

All three HB2 hair dryer samples passed the ISTA-2A random vibration test, demonstrating stable performance with no abnormalities in appearance or charging function after 1 hour of multi-axis vibration exposure.

  • Product: HB2 Hair Dryer (HB2-吹风机)
  • Standard: ISTA-2A
  • Test Mode: Random vibration, X/Y/Z axes
  • Duration: 1 hour
  • Vibration Frequency: 4 Hz
  • Test Speed (CMP): 240 G
  • Vibration Amplitude: 25.4 mm
  • Samples: 3 units
  • Verdict: PASS

Test Overview

Field Detail
Report Title Vibration Test Report
Report Number 20250419001
Page 1
Date 2025-04-19
Product Name HB2 Hair Dryer (HB2-吹风机)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 PCS
Test Class / Standard ISTA-2A
Test Reason New Product
Test Objective To verify the resistance of the sample under transportation and use-environment vibration conditions, simulating various vibrations encountered during transport and actual use.
Laboratory Environment Temperature: 30 °C; Humidity: 55% RH

Test Equipment & Setup

Parameter Value
Instrument Name Vibration Testing Machine
Test Mode Random Mode
Test Duration 1 H
Random Directions X, Y, Z
Vibration Frequency 4 Hz
Test Speed (CMP) 240 G
Vibration Amplitude 25.4 mm
Test Requirement Performance evaluation under vibration environment; verify stability and durability during use

Test Procedure

  1. Pre-test inspection: Visually inspect all 3 HB2 samples for any pre-existing cosmetic defects or functional issues. Document initial condition. Verify laboratory environment is within specified conditions (30 °C, 55% RH).
  2. Sample placement: Mount samples on the vibration testing machine platform in the standard orientation as shown in test placement photos.
  3. Configure equipment: Set vibration testing machine to Random Mode, frequency 4 Hz, amplitude 25.4 mm, test speed CMP 240 G, duration 1 hour.
  4. Execute vibration — X axis: Run the random vibration profile along the X axis for the programmed duration as part of the 1-hour total test cycle.
  5. Execute vibration — Y axis: Continue random vibration along the Y axis.
  6. Execute vibration — Z axis: Continue random vibration along the Z axis, completing all three directional exposures within the 1-hour test window.
  7. Post-test inspection: Remove samples from the test platform. Visually inspect all surfaces for cracks, deformation, or cosmetic damage. Test charging function on each sample. Document all observations.
  8. Acceptance criteria: Samples pass if appearance shows no abnormalities and charging function operates normally after completion of the full vibration cycle.

Test Data & Results

Sample Test Condition Appearance After Test Charging Function After Test Result
HB2 #1 Random, X/Y/Z, 4 Hz, 240 G CMP, 25.4 mm, 1 H, 30 °C / 55% RH No abnormality Normal PASS
HB2 #2 Random, X/Y/Z, 4 Hz, 240 G CMP, 25.4 mm, 1 H, 30 °C / 55% RH No abnormality Normal PASS
HB2 #3 Random, X/Y/Z, 4 Hz, 240 G CMP, 25.4 mm, 1 H, 30 °C / 55% RH No abnormality Normal PASS

Overall Test Result: HB2 samples maintained stable performance under various vibration and transport environment conditions. No abnormalities were observed in appearance, and charging functioned normally for all three units. Overall judgment: Pass (合格).

Conclusion

Item Detail
Test Standard ISTA-2A
Test Conditions Random vibration, X/Y/Z axes, 4 Hz, 240 G CMP, 25.4 mm amplitude, 1 H, 30 °C / 55% RH
Samples Tested 3 PCS (HB2 Hair Dryer)
Appearance No abnormality observed on any sample
Charging Function Normal on all samples
Overall Verdict PASS (合格)

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Review (审查) Zhang Ronggui
Tester (试验人) Li Guanghua
Form Number (表单编号) BTK-R-Q-087A/1

Frequently Asked Questions

What does the ISTA-2A vibration test evaluate for the HB2 hair dryer?

The ISTA-2A test simulates the random vibration stresses a packaged or unpackaged product encounters during transport and handling. For the HB2 hair dryer, it verifies that the unit’s structure, cosmetic finish, and electrical functions — particularly charging — remain intact after exposure to multi-axis random vibration at 4 Hz frequency, 240 G CMP, and 25.4 mm amplitude over one hour.

Did all HB2 samples pass the vibration test?

Yes. All three HB2 hair dryer samples passed. After completing the full 1-hour random vibration cycle across X, Y, and Z axes, every sample showed no abnormalities in appearance and charging function operated normally. The official judgment is Pass (合格).

What were the exact vibration test parameters used for the HB2?

The test used a vibration testing machine in Random Mode. Key parameters: frequency 4 Hz, test speed CMP 240 G, vibration amplitude 25.4 mm, test duration 1 hour, random directions X/Y/Z, laboratory temperature 30 °C, and humidity 55% RH.

Why is transport vibration testing important for hair dryers?

Hair dryers contain internal motor assemblies, heating elements, and plastic housings that can develop micro-cracks, loose connections, or cosmetic damage under the repetitive mechanical stress of shipping and logistics. Transport vibration testing to ISTA-2A ensures that products reaching end users are structurally and functionally uncompromised, reducing warranty returns and field failures.

Related Products