ETENWOLF Air3 Hair Dryer Air Pressure and Airflow Test Report

Document Overview

Key Findings All three Air3 units passed the TB1 airflow and air pressure evaluation, delivering consistent wind pressure between 0.67–0.73 psi and nozzle-free airflow between 155–162 NL/M. Test Type: Air Pressure and Airflow (TB1) Product: ETENWOLF Air3 Hair Dryer Sample Size: 3 units Wind Pressure…

Document type
Test Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Airflow

Key Findings

All three Air3 units passed the TB1 airflow and air pressure evaluation, delivering consistent wind pressure between 0.67–0.73 psi and nozzle-free airflow between 155–162 NL/M.

  • Test Type: Air Pressure and Airflow (TB1)
  • Product: ETENWOLF Air3 Hair Dryer
  • Sample Size: 3 units
  • Wind Pressure Range: 0.67–0.73 psi
  • Nozzle-Free Airflow Range: 155–162 NL/M
  • Overall Result: All samples within acceptable range

Test Overview

Item Detail
Test Type TB1 Air Pressure and Airflow Test
Report Reference TB1吹风机风压和风量测试数据20250307
Test Date 2025-03-07
Product ETENWOLF Air3 Hair Dryer
Product Line Inflation Tools
Category Hair Dryer (吹风机类)
Sample Quantity 3 units (1#, 2#, 3#)
Source File TB1吹风机风压和风量测试数据20250307.xlsx

Test Equipment & Setup

Parameter Detail
Pressure Unit psi (pounds per square inch)
Airflow Unit NL/M (Normal Litres per Minute)
Nozzle Condition No nozzle attached (bare outlet)
Test Protocol TB1 internal standard
Data Sheet Sheet1 (single sheet workbook)

Test Procedure

  1. Pre-test: Inspect each Air3 unit for physical damage and confirm factory default settings.
  2. Setup: Remove any nozzle attachments to ensure bare-outlet measurement conditions.
  3. Pressure Measurement: Connect a calibrated pressure gauge to the outlet and record the static wind pressure in psi for each unit.
  4. Airflow Measurement: Using a calibrated flow meter, measure the nozzle-free airflow volume and record in NL/M.
  5. Recording: Log results for each sample (1#, 2#, 3#) along with any observations in the remarks column.
  6. Post-test: Verify readings are within the specified acceptance range; note any anomalies.
  7. Acceptance Criteria: All units must produce consistent air pressure and airflow values within the normal distribution of the sample set; no unit shall show a significant outlier deviation.

Test Data & Results

Sample No. Wind Pressure (psi) Nozzle-Free Airflow (NL/M) Remarks
1# 0.67 155
2# 0.72 162
3# 0.73 161

All three samples produced stable readings. Unit 1# recorded the lowest pressure (0.67 psi) and airflow (155 NL/M), while units 2# and 3# were closely matched at 0.72–0.73 psi and 161–162 NL/M respectively. The spread across samples is narrow, indicating good unit-to-unit consistency.

Conclusion

Item Detail
Result Pass
Protocol TB1 Air Pressure and Airflow Test
Test Conditions Nozzle-free bare outlet; pressure in psi; airflow in NL/M
Samples Tested 3 units (1#, 2#, 3#)
Wind Pressure Range 0.67–0.73 psi
Airflow Range 155–162 NL/M
Verdict All units demonstrated consistent performance within acceptable limits

Document Information

Role Name Detail
Author / Tester Alex Newman Translated and structured from source file TB1吹风机风压和风量测试数据20250307.xlsx
Source File Date 2025-03-07
Form Reference TB1吹风机风压和风量测试数据20250307
Sheet Sheet1 (1 of 1)

Frequently Asked Questions

What wind pressure does the ETENWOLF Air3 produce?

In TB1 testing across three production units, the Air3 produced wind pressure readings of 0.67, 0.72, and 0.73 psi, giving a range of 0.67–0.73 psi under bare-outlet conditions with no nozzle attached.

What is the nozzle-free airflow of the ETENWOLF Air3?

With no nozzle attached, the three Air3 test units delivered airflow volumes of 155, 162, and 161 NL/M (Normal Litres per Minute), showing strong consistency across samples.

What does the TB1 air pressure and airflow test measure?

The TB1 protocol measures two key performance metrics of a hair dryer: static wind pressure at the outlet (in psi) and volumetric airflow (in NL/M) under bare-outlet conditions, providing a baseline for comparing fan and motor performance across units.

Did all ETENWOLF Air3 units pass the airflow test?

Yes. All three Air3 units tested under the TB1 protocol passed, showing consistent pressure and airflow values with no significant outliers detected among the sample set.

Related Products