ETENWOLF HB2 Hair Dryer High/Low Temperature Storage Test Report (72 h, ±Extreme Cycle)

Document Overview

Key Findings The ETENWOLF HB2 Hair Dryer successfully completed a 72-hour high/low temperature storage test with no appearance anomalies, normal power-button function, and normal charging operation after exposure — result: Pass. Product: HB2 Hair Dryer (HB2-吹风机) Manufacturer: BTK Samples: 3 pcs High-temp condition: 60 °C,…

Document type
Test Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The ETENWOLF HB2 Hair Dryer successfully completed a 72-hour high/low temperature storage test with no appearance anomalies, normal power-button function, and normal charging operation after exposure — result: Pass.

  • Product: HB2 Hair Dryer (HB2-吹风机)
  • Manufacturer: BTK
  • Samples: 3 pcs
  • High-temp condition: 60 °C, 80 % RH, 2 h
  • Low-temp condition: −20 °C, 2 h
  • Total storage duration: 72 h
  • Test dates: 2025-04-17 to 2025-04-21
  • Verdict: Pass

Test Overview

Field Detail
Test Type High / Low Temperature Storage Test (高低温存储测试)
Report Number 2025042101
Page 1
Test Dates 2025-04-17 to 2025-04-21
Product Name HB2 Hair Dryer (HB2-吹风机)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 pcs
Test Reason New Product (■ New product selected)
Test Purpose Evaluate the durability of the prototype stored under extreme temperature environments
Laboratory Environment Temperature 24 °C; Humidity 45 % RH
Test Class / Grade (Not specified)

Test Equipment & Setup

Item Detail
Instrument Name Constant Temperature and Humidity Testing Machine (恒温恒湿试验机)
High-Temp Condition 60 °C, Humidity 80 % RH, duration 2 h
Low-Temp Condition −20 °C, duration 2 h
Total Storage Duration 72 h
Post-Storage Verification Functional test (power on / button function / charging)

Test Procedure

  1. Pre-test: Record baseline appearance and functional status of all 3 HB2 samples. Photograph samples before testing (试验前图).
  2. High-temperature exposure: Place samples in the constant temperature and humidity chamber. Set chamber to 60 °C and 80 % RH. Hold for 2 hours.
  3. Low-temperature exposure: Adjust chamber to −20 °C. Hold for 2 hours.
  4. Extended storage: Continue storage cycle to accumulate a total of 72 hours of combined climate exposure. Monitor program-control chart (程序控制图) throughout.
  5. Post-test inspection: Remove samples from chamber. Photograph samples after testing (试验后图).
  6. Functional verification: Inspect appearance for anomalies. Power on each unit and confirm power-button response. Verify charging function operates normally.
  7. Acceptance criteria: No functional failure; normal power-on confirmed; no appearance defects. Any failure → result recorded as Fail.

Test Data & Results

Check Item Requirement Observation After 72 h Storage Result
Appearance No abnormality No appearance anomalies detected on any of the 3 samples Pass
Power-on / Button Function Normal power-on; button operates correctly Power button functioned normally on all 3 samples Pass
Charging Function Charging operates normally Charging confirmed normal on all 3 samples Pass

Observations: After 72 hours of high/low temperature climate storage conditions, all three HB2 hair dryer samples exhibited no appearance anomalies, normal power-button function, and normal charging behavior. The test image set comprised: pre-test photo (试验前图), program control chart (程序控制图), and post-test photo (试验后图).

Conclusion

Field Detail
Overall Result Pass (■合格)
Test Conditions High temp: 60 °C / 80 % RH / 2 h; Low temp: −20 °C / 2 h; Total: 72 h storage
Standard / Requirement No functional failure; normal power-on after storage
Samples Tested 3 pcs HB2 Hair Dryer
Verdict All samples passed appearance inspection and functional verification

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Review (审查) Zhang Ronggui
Tester (试验人) Li Guanghua
Form Number BTK-R-Q-087A/1

Frequently Asked Questions

What temperature range was the ETENWOLF HB2 Hair Dryer tested at?

The HB2 was tested at both a high temperature of 60 °C with 80 % relative humidity for 2 hours and a low temperature of −20 °C for 2 hours, with a total combined storage duration of 72 hours.

Did the HB2 Hair Dryer pass the high/low temperature storage test?

Yes. All three HB2 samples passed. After 72 hours of extreme temperature storage, every unit showed no appearance anomalies, normal power-button operation, and normal charging function. The official verdict is Pass.

What equipment was used for the HB2 temperature storage test?

The test was conducted using a Constant Temperature and Humidity Testing Machine (恒温恒湿试验机) under laboratory ambient conditions of 24 °C and 45 % RH.

Why is high/low temperature storage testing important for hair dryers?

Hair dryers are shipped and stored across a wide range of climates. Extreme temperatures can degrade plastics, seals, and electronic components. This test confirms that the HB2 retains full functionality after exposure to both high heat and sub-zero cold, ensuring product reliability throughout the supply chain.

Related Products