ETENWOLF HB1 Air Pump Transport Vibration Test Report (ISTA-2A, Random Mode, 1H)

Document Overview

Key Findings All 6 HB1 air pump samples successfully passed the simulated transport vibration test under ISTA-2A protocol, with no functional failure, stable working performance, and good durability. Product: HB1 Air Pump (HB1-吹气泵) Standard: ISTA-2A Report No.: 2025072301 Test Date: 2025-07-23 Samples: 6 PCS Test…

Document type
Test Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

All 6 HB1 air pump samples successfully passed the simulated transport vibration test under ISTA-2A protocol, with no functional failure, stable working performance, and good durability.

  • Product: HB1 Air Pump (HB1-吹气泵)
  • Standard: ISTA-2A
  • Report No.: 2025072301
  • Test Date: 2025-07-23
  • Samples: 6 PCS
  • Test Mode: Random vibration, axes X / Y / Z
  • Duration: 1 hour
  • Frequency: 4 Hz
  • Amplitude: 25.4 mm
  • Speed (CMP): 240 G
  • Verdict: PASS

Test Overview

Field Details
Test Type Vibration Test (Transport Simulation)
Test Standard ISTA-2A
Report No. 2025072301
Page 1
Date 2025-07-23
Product Name HB1 Air Pump (HB1-吹气泵)
Manufacturer BTK
Surface Treatment /
Sample Quantity 6 PCS
Test Reason New Product
Test Objective To verify the resistance of the sample under transportation and use environment vibration conditions.
Laboratory Environment Temperature: 30 °C; Humidity: 55% RH

Test Equipment & Setup

Item Parameter Value
Instrument Name Vibration Testing Machine
Test Mode Pattern Random Mode
Test Duration Time 1 H
Vibration Axes Direction X, Y, Z (Random)
Vibration Frequency Frequency 4 Hz
Test Speed CMP 240 G
Vibration Amplitude Amplitude 25.4 mm
Test Class / Standard Level ISTA-2A

Test Procedure

  1. Pre-Test Inspection: Power on each of the 6 HB1 samples and confirm normal startup operation. Verify charging function is normal. Record initial condition of all samples.
  2. Sample Placement: Mount samples on the vibration table in the designated orientation as shown in the vibration placement diagram (振动摆放).
  3. Parameter Configuration: Set the vibration testing machine to Random Mode, frequency 4 Hz, amplitude 25.4 mm, speed 240 G, axes X / Y / Z.
  4. Vibration Test Execution: Run the test for 1 hour continuously. Monitor the vibration control chart (振动控制图) throughout the test duration.
  5. Post-Test Inspection: Power on all samples after vibration. Verify power-on operation is normal. Verify charging function remains normal. Perform visual inspection for any physical damage or loose components.
  6. Acceptance Criteria: All samples must power on and operate normally with no functional failure, stable working performance, and acceptable durability after completion of the full 1-hour vibration cycle.

Test Data & Results

Check Item Pre-Test Status Post-Test Status Result
Power-On Operation Normal Normal Pass
Charging Function Normal Normal Pass
Vibration Placement Setup Confirmed Pass
Vibration Control Chart Monitored & Stable Pass
Physical / Structural Integrity No defects No defects Pass

Overall test result: All 6 samples passed the simulated transport vibration test. No functional failures were observed. Working performance remained stable throughout and after the test. Durability assessed as good.

Judgment: ■ Pass    □ Fail    □ Reference

Conclusion

Field Details
Test Result All samples passed the simulated transport vibration test with no functional failure.
Standard Applied ISTA-2A
Test Conditions Random mode; 4 Hz; 25.4 mm amplitude; 240 G CMP; X/Y/Z axes; 1 hour; 30 °C / 55% RH
Samples Tested 6 PCS — HB1 Air Pump
Working Performance Stable
Durability Assessment Good
Verdict PASS

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Review (审查) Zhang Ronggui
Tester (试验人) Li Guanghua
Form Number BTK-R-Q-087A/1

Frequently Asked Questions

What standard was used for the HB1 air pump vibration test?

The HB1 air pump vibration test was conducted in accordance with ISTA-2A, a widely recognized international standard for simulating transport vibration environments for packaged products.

What were the vibration test parameters for the HB1 air pump?

The test used random mode vibration across X, Y, and Z axes for 1 hour. Key parameters were: frequency 4 Hz, vibration amplitude 25.4 mm, and test speed 240 G CMP, conducted at 30 °C and 55% RH.

Did the ETENWOLF HB1 air pump pass the transport vibration test?

Yes. All 6 HB1 air pump samples passed the ISTA-2A transport vibration test with no functional failure. Power-on operation and charging function remained normal after the full 1-hour vibration cycle, and durability was assessed as good.

How many samples were tested in the HB1 vibration test?

Six (6) HB1 air pump units were tested simultaneously. All 6 samples passed with stable performance and no defects observed before or after the vibration test.