ETENWOLF HB1 Air Pump Thermal Rise Test Report (Full Discharge Cycle, 2 Samples)

Document Overview

Key Findings The HB1 air pump completed a full-charge-to-discharge thermal test on 2025-07-24, with both samples demonstrating moderate temperature rise across all monitored points, and results recorded for reference. Report No.: 2025072401 Samples: HB1-4# and HB1-5# (2 PCS) Ambient Temperature: 27.4 °C Peak Motor Temp…

Document type
Certification Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The HB1 air pump completed a full-charge-to-discharge thermal test on 2025-07-24, with both samples demonstrating moderate temperature rise across all monitored points, and results recorded for reference.

  • Report No.: 2025072401
  • Samples: HB1-4# and HB1-5# (2 PCS)
  • Ambient Temperature: 27.4 °C
  • Peak Motor Temp (HB1-4#): 43.1 °C — rise of 15.7 K
  • Peak Motor Temp (HB1-5#): 38.4 °C — rise of 11.0 K
  • Battery Max Temp: 34.2 °C (4#) / 32.4 °C (5#)
  • Air Outlet Max Temp: 32.4 °C (4#) / 32.6 °C (5#)
  • Verdict: For Reference Only (供参考)

Test Overview

Field Details
Product No. / Name HB1 — Air Pump (HB1-吹气泵)
Report No. 2025072401
Test Date 2025-07-24
Sample Quantity / No. 2 PCS — 4# and 5#
Test Type Reliability Test (可靠性测试)
Test Standard Internal Standard (内部标准)
Test Purpose Evaluate sample thermal stability, heat dissipation performance, and potential overheating risk
Test Criterion Evaluate performance stability of sample temperature variation
Product Line Inflation Tools
Category Air Blower / Pump Class (吹风机类)

Test Equipment & Setup

Parameter Description
Test Method Sample powered on at full charge under room temperature, run continuously until battery fully depleted
Measurement Points Motor, Battery, Air Outlet, Ambient
Ambient Temperature 27.4 °C
Initial State Full charge (满电)
Run Condition Continuous operation from power-on to battery exhaustion
Data Collected Temperature change data sampled throughout discharge cycle (see sibling sheet: 温升变化数据)
Test Photos Internal wiring (内部接线); in-operation thermal image (温升运行中)

Test Procedure

  1. Pre-test: Confirm sample battery is fully charged. Record ambient temperature (27.4 °C). Prepare temperature measurement equipment and assign sample IDs (4#, 5#).
  2. Setup: Place samples in ambient environment. Attach or position temperature probes at three measurement points: motor, battery, and air outlet.
  3. Operation: Power on sample at room temperature in full-charge state. Allow continuous operation without interruption.
  4. Data Collection: Record temperature readings at each measurement point throughout the run. Capture thermal images during operation (温升运行中).
  5. End Condition: Test concludes when battery is fully depleted and device shuts off.
  6. Post-test: Record peak temperatures and calculate temperature rise (K) for each measurement point by subtracting ambient temperature from the peak reading.
  7. Acceptance Criteria: Evaluate performance stability of temperature variation. Results in this report are classified as For Reference Only (供参考) — no pass/fail threshold applied.

Test Data & Results

Sample ID Measurement Item Motor (°C / K) Battery (°C / K) Air Outlet (°C / K) Ambient Temp (°C)
HB1-4# Peak Temperature (°C) 43.1 34.2 32.4 27.4
HB1-4# Temperature Rise (K) 15.7 6.8 5.0
HB1-5# Peak Temperature (°C) 38.4 32.4 32.6 27.4
HB1-5# Temperature Rise (K) 11.0 5.0 5.2

Observations: HB1-4# recorded a higher motor peak temperature (43.1 °C, +15.7 K) compared to HB1-5# (38.4 °C, +11.0 K), a difference of 4.7 K at the motor point. Battery and air outlet temperature rises were comparable across both samples, all remaining below 7 K above ambient. Detailed time-series temperature change data is available in the companion sheet (温升变化数据). Note from report: test data is on the next sheet.

Conclusion

Field Details
Result Classification For Reference Only (供参考 ■)
Pass Not marked (口合格)
Fail Not marked (口不合格)
Test Standard Internal Standard
Test Conditions Full charge, continuous discharge, ambient 27.4 °C
Samples Tested HB1-4#, HB1-5# (2 PCS)
Verdict Thermal performance data recorded for engineering reference; no formal pass/fail threshold applied in this test cycle

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-07-24
Reviewed By (审核/日期) Zhang Ronggui 2025-07-24
Approved By (审核/日期) Mai Shaoqiang 2025-07-24
Field Details
Source File HB1吹气泵-温升报告-2025.7.24.xlsx
Sheet Name 温升报告 (Sheet 1 of 2)
Report No. 2025072401

Frequently Asked Questions

What does the HB1 air pump thermal rise test measure?

The test measures peak temperatures and temperature rise (in Kelvin) at three points — the motor, battery, and air outlet — while the HB1 runs continuously from a full charge until the battery is depleted. This evaluates thermal stability and heat dissipation performance under a realistic worst-case discharge scenario.

What were the highest temperatures recorded for the HB1 during thermal testing?

With an ambient temperature of 27.4 °C, the motor on sample HB1-4# reached the highest recorded temperature of 43.1 °C (a rise of 15.7 K). Sample HB1-5# peaked at 38.4 °C at the motor (rise of 11.0 K). Battery and air outlet temperatures on both samples rose less than 7 K above ambient.

Did the HB1 pass the thermal rise test?

This test cycle was classified as For Reference Only (供参考) — no formal pass/fail threshold was applied. The data is intended for engineering evaluation of thermal stability and heat dissipation rather than compliance certification.

Where can I find the full time-series temperature data for the HB1 thermal test?

The complete temperature change data recorded throughout the discharge cycle is available in the companion sheet 温升变化数据 from the same Excel workbook (HB1吹气泵-温升报告-2025.7.24.xlsx). A cross-linked article covering that dataset is listed in the Related Products section below.