ETENWOLF X6PRO Tire Inflator Illuminance Test Report (10 cm, Front White Light, 2026)

Document Overview

Key Findings All three X6PRO samples measured front white-light illuminance between 1,861 LUX and 1,962 LUX at 10 cm distance, confirming consistent LED output across the production batch. Product: X6PRO Tire Inflator (Air Pump) Report No.: 20260207-001 Test Date: 2026-02-07 Sample Size: 3 units Distance:…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Illuminance Testing

Key Findings

All three X6PRO samples measured front white-light illuminance between 1,861 LUX and 1,962 LUX at 10 cm distance, confirming consistent LED output across the production batch.

  • Product: X6PRO Tire Inflator (Air Pump)
  • Report No.: 20260207-001
  • Test Date: 2026-02-07
  • Sample Size: 3 units
  • Distance: 10 cm
  • Light Mode: Front White Light (正面白光)
  • Illuminance Range: 1,861 – 1,962 LUX
  • Verdict: For Reference Only (供参考)

Test Overview

Field Detail
Product No. / Name Air Pump (充气泵)
Model / Type Specification X6PRO
Report No. 20260207-001
Test Date 2026-02-07
Sample Quantity / No. 3 PCS
Test Type ■ Reliability Test (可靠性测试)
Test Standard Internal Standard (内部标准)
Test Purpose Verify whether the actual illumination performance of the product matches the nominal parameters (验证产品实际照明性能是否匹配标称参数)
Acceptance Criterion Ensure the product meets usage requirements across different scenarios (确保满足不同场景的使用需求)
Manufacturer / Brand ETENWOLF

Test Equipment & Setup

Item Detail
Test Equipment Illuminance Meter (照度计 / LX Meter), Range: 0 – 20,000 LUX
Measurement Distance 10 cm (probe placed horizontally at measurement point)
Measurement Location Dark room (暗室); probe aligned to lamp-axis light source maximum value
Probe Orientation Horizontal
Ambient Temperature 23 °C
Relative Humidity 60 %
Photo Reference 10 cm LED high-brightness setup (10cm LED高亮)

Test Procedure

  1. Pre-test: Confirm test environment — dark room, ambient temperature 23 °C, relative humidity 60 %.
  2. Equipment check: Verify illuminance meter range is set to 0 – 20,000 LUX and calibration is current.
  3. Sample preparation: Label three X6PRO units as 1#, 2#, and 3#; fully charge each unit before testing.
  4. Positioning: Place the illuminance meter probe horizontally at exactly 10 cm from the front light source, aligned to the lamp axis.
  5. Measurement: Activate front white light mode on each sample; record the maximum illuminance value (LUX) displayed on the meter.
  6. Repeat: Perform the measurement for all three samples (1#, 2#, 3#) under identical conditions.
  7. Post-test: Record results, photograph the test setup, and compare readings against nominal parameters.

Acceptance Criteria: Results are evaluated against the product’s nominal illuminance specification to ensure performance meets usage requirements across different scenarios. This test is classified as For Reference Only.

Test Data & Results

Sample No. (编号) Distance (cm) (距离) Light Mode (灯光) Illuminance Value (LUX) (照度值)
1# 10 Front White Light (正面白光) 1,861
2# 10 Front White Light (正面白光) 1,962
3# 10 Front White Light (正面白光) 1,891

Observations: All three units produced illuminance readings within a narrow band of 101 LUX (1,861 – 1,962 LUX), demonstrating good unit-to-unit consistency. The test image caption notes "10 cm LED high-brightness" confirming the high-output LED mode was active during measurement. No anomalies or equipment faults were recorded. Remarks/Notes field was left blank by the tester.

Conclusion

Field Detail
Test Item Illuminance Performance (照度性能)
Standard Applied Internal Standard (内部标准)
Test Conditions 23 °C, 60 % RH, dark room, 10 cm distance, front white light
Samples Tested 3 PCS (1#, 2#, 3#)
Illuminance Range Measured 1,861 – 1,962 LUX
Pass (合格)
Fail (不合格)
Verdict ■ For Reference Only (供参考)

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua (李光华) 2026-02-07
Checked By (审核/日期) Zhang Ronggui (张荣贵) 2026-02-07
Approved By (核准/日期) Mai Shaoqiang (麦少强) 2026-02-07
Field Detail
Source File X6PRO-_光照度测试2026.2.7.xlsx
Sheet Name 照度值测试 (Illuminance Value Test)
Report No. 20260207-001
Product Line Inflation Tools
Category Air Pump Products (0气泵类项目)

Frequently Asked Questions

What illuminance does the ETENWOLF X6PRO produce at 10 cm?

In this test, the X6PRO front white light measured between 1,861 LUX and 1,962 LUX at a 10 cm distance in a dark room, with all three samples averaging approximately 1,905 LUX.

What test standard was used for the X6PRO illuminance test?

The test was conducted against ETENWOLF’s internal standard. The procedure follows the method of placing an illuminance meter probe horizontally at 1 metre — and in this specific close-range test, at 10 cm — from the lamp axis in a dark room to capture the maximum illuminance value.

Why is the X6PRO illuminance result listed as "For Reference Only"?

The "For Reference Only" (供参考) designation means the data is used to characterise and document actual product performance against nominal parameters rather than as a pass/fail compliance verdict. This is common practice for internal reliability tests where the goal is performance benchmarking.

How consistent is the LED output across different X6PRO units?

The three units tested showed very consistent output. The spread between the lowest (1,861 LUX) and highest (1,962 LUX) readings was only 101 LUX — approximately 5.4% variation — indicating tight manufacturing consistency in the LED assembly.

Related Products