ETENWOLF EV3 Tire Inflator Transportation Vibration Test Report (ISTA-2A, 1 Hour Random)

Document Overview

Key Findings The ETENWOLF EV3 tire inflator passed a 1-hour random vibration test per ISTA-2A, with all 3 samples showing normal power-on function, unaffected inflation accuracy, and no appearance or button anomalies after testing. Product: EV3 Tire Inflator (EV3-充气泵) Test Standard: ISTA-2A Report No.: 2025040901…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

The ETENWOLF EV3 tire inflator passed a 1-hour random vibration test per ISTA-2A, with all 3 samples showing normal power-on function, unaffected inflation accuracy, and no appearance or button anomalies after testing.

  • Product: EV3 Tire Inflator (EV3-充气泵)
  • Test Standard: ISTA-2A
  • Report No.: 2025040901
  • Test Date: 2025-04-09
  • Sample Quantity: 3 PCS
  • Test Duration: 1 Hour
  • Test Mode: Random vibration, X / Y / Z axes
  • Vibration Frequency: 4 Hz
  • Test Speed (CMP): 240 G
  • Vibration Amplitude: 25.4 mm
  • Verdict: PASS

Test Overview

Field Detail
Test Type Vibration Test (Transportation Vibration)
Test Standard ISTA-2A
Report No. 2025040901
Page 1
Date 2025-04-09
Product Name EV3 Tire Inflator (EV3-充气泵)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 PCS
Test Reason New Product
Test Objective To verify the resistance of the sample in transportation and use environment.
Laboratory Temperature 22 °C
Laboratory Humidity 55% RH
Test Class ISTA-2A

Test Equipment & Setup

Parameter Detail
Instrument Name Vibration Testing Machine
Test Mode Random Mode
Test Duration 1 Hour
Vibration Axes Random Direction: X, Y, Z
Vibration Frequency 4 Hz
Test Speed (CMP) 240 G
Vibration Amplitude 25.4 mm

Test Procedure

  1. Pre-Test: Record the laboratory environment (temperature 22 °C, humidity 55% RH). Inspect all 3 EV3 samples for appearance and confirm normal power-on and functional operation prior to testing. Document pre-test condition with photographs (vibration placement, control diagram, and test duration setup).
  2. Mounting: Secure the sample(s) on the vibration testing machine platform in accordance with the ISTA-2A test configuration.
  3. Vibration Execution: Apply random vibration in all three axes (X, Y, Z) at a frequency of 4 Hz, amplitude of 25.4 mm, and a CMP test speed of 240 G for a continuous duration of 1 hour.
  4. Post-Test Inspection: After completing the 1-hour vibration cycle, power on each sample and verify: (a) normal start-up and operation, (b) no functional failure, (c) no appearance or button anomalies, (d) normal charging function, and (e) normal inflation accuracy.
  5. Acceptance Criteria: After testing, the product must power on normally and exhibit no functional failures. Inflation accuracy must remain within specification. Any failure in power-on, function, appearance, or accuracy constitutes a test failure.

Test Data & Results

Check Item Pre-Test Status Post-Test Status Result
Power-On / Normal Start-Up Normal Normal — no anomaly after 1-hour vibration Pass
Overall Function Normal Performance unaffected by vibration Pass
Appearance & Buttons Normal No appearance or button anomalies Pass
Charging Function Normal Charging normal Pass
Inflation Accuracy Normal Inflation accuracy normal (OK) Pass

Test Result Summary: After 1 hour of vibration testing, all 3 EV3 tire inflator samples powered on and operated without anomaly. Performance was not affected by vibration. Appearance and button functions were normal. Inflation accuracy test result: OK.

Judgment: ■ Pass   □ Fail   □ Reference

Conclusion

Field Detail
Product EV3 Tire Inflator
Test Standard ISTA-2A
Test Conditions Random vibration; X/Y/Z axes; 4 Hz; 240 G CMP; 25.4 mm amplitude; 1 hour; 22 °C / 55% RH
Samples Tested 3 PCS
Functional Result Normal power-on, no functional failure, inflation accuracy OK
Appearance Result No anomalies to appearance or buttons
Charging Result Charging normal
Overall Verdict PASS

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Review (审查) Zhang Ronggui
Tester (试验人) Li Guanghua
Form Number BTK-R-Q-087A/1
Report No. 2025040901
Date 2025-04-09

Frequently Asked Questions

What does the ETENWOLF EV3 vibration test verify?

The ETENWOLF EV3 transportation vibration test verifies the product’s resistance to the mechanical stresses experienced during shipping and real-world use. It confirms that after 1 hour of random vibration across all three axes (X, Y, Z) at 4 Hz and 25.4 mm amplitude, the EV3 inflator powers on normally, retains accurate inflation readings, and shows no damage to appearance or buttons.

Which standard was used for the EV3 vibration test?

The EV3 vibration test was conducted to the ISTA-2A test class, which is an internationally recognized protocol for evaluating packaged products under simulated transportation environments including random vibration.

What were the vibration test parameters for the EV3 inflator?

The EV3 vibration test used the following parameters: test mode — random; duration — 1 hour; axes — X, Y, and Z; vibration frequency — 4 Hz; test speed (CMP) — 240 G; vibration amplitude — 25.4 mm. The laboratory environment was maintained at 22 °C and 55% relative humidity throughout the test.

Did all EV3 samples pass the vibration test?

Yes. All 3 EV3 tire inflator samples passed the ISTA-2A vibration test. After the 1-hour random vibration cycle, every sample powered on without anomaly, charging function was normal, inflation accuracy remained within specification, and no appearance or button defects were observed. The official judgment is Pass.