ETENWOLF S0 Portable Bike Pump Life Cycle Endurance Test Report (Motor Reliability, 13 H Run)

Document Overview

Key Findings The ETENWOLF S0 portable bike pump completed a 13-hour charge-discharge endurance cycle under internal reliability standards; one of three samples failed to inflate at the 19-hour mark, and the overall result is classified as For Reference Only. Report No.: 2025081401 Test Dates: 2025-08-04…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

The ETENWOLF S0 portable bike pump completed a 13-hour charge-discharge endurance cycle under internal reliability standards; one of three samples failed to inflate at the 19-hour mark, and the overall result is classified as For Reference Only.

  • Report No.: 2025081401
  • Test Dates: 2025-08-04 to 2025-08-14
  • Samples: 3 pcs (S0-6#, S0-7#, S0-8#)
  • Logged Run Time: 13 hours
  • Test Standard: Internal Control Standard — 10 H charge-discharge life target
  • Inflation Accuracy (post-aging): 6# 110.1 psi / 2:02 min, 7# 110.2 psi / 2:35 min, 8# 110.2 psi / 2:38 min
  • Anomalies: Intermittent E14 high-temperature protection during aging; 1 sample (6#) unable to inflate at 19 h; 1 sample showing E21 fault
  • Verdict: For Reference Only

Test Overview

Field Details
Test Title Inflation Pump Life Cycle Test (充气泵寿命测试)
Product No. / Name ETENWOLF S0 Portable Bike Pump (充气泵 — 磨针)
Model / Type Specification S0
Report No. 2025081401
Test Dates 2025-08-04 to 2025-08-14
Sample Quantity / ID 3 PCS — S0-6#, S0-7#, S0-8#
Test Type Reliability Test (可靠性测试)
Test Standard Internal Control Standard (内控标准)
Test Purpose Evaluate the reliability of the motor service life (评估样品马达寿命使用的可靠性)
Test Conditions Room Temperature 23 °C, Relative Humidity 60 %
Test Equipment Power Supply (电源)
Remarks / Notes

Test Equipment & Setup

Parameter Value
Test Equipment Power Supply (电源)
Ambient Temperature 23 °C
Relative Humidity 60 %
Life Target (Standard) 10 H charge-discharge cycles (充放电寿命标准 10H)
Charge Duration (observed) Approx. 1 hour 20 minutes per cycle
Discharge Duration (observed) Approx. 15 minutes per cycle
Total Test Run Logged 13 hours
Acceptance Criterion No failure of function; stable operation throughout (确保功能无失效,观察其稳定性)

Test Procedure

  1. Pre-test: Fully charge all three samples (S0-6#, S0-7#, S0-8#) before starting the endurance run.
  2. Cycle start: Begin discharge by running the pump continuously until battery is fully depleted.
  3. Recharge: Reconnect to power supply and recharge until full; record charge duration (~1 h 20 min per cycle).
  4. Repeat cycles: Continue charge-discharge cycles targeting a cumulative run time of at least 10 hours (internal life standard).
  5. Monitoring: Observe samples throughout aging for thermal events, error codes, and functional anomalies. Log any E14 (high-temperature protection) or other fault codes.
  6. Post-test inspection: After aging, verify inflation accuracy and time for each sample; inspect exterior appearance for any physical defects.
  7. Acceptance criteria: All samples must complete 10 H of charge-discharge operation with no functional failure and stable performance throughout the aging process.

Test Data & Results

Sample ID Test Duration (Hours) Issue Description / Observations
S0-6# / S0-7# / S0-8# 13
  1. Battery charge and discharge function normal after life test; charge time approx. 1 hour 20 minutes, discharge time approx. 15 minutes.
  2. Sample performance stable during aging process; able to work continuously and stably; E14 high-temperature protection triggered intermittently.
  3. Post-aging inflation accuracy and time — 6#: 110.1 psi / 2:02 min; 7#: 110.2 psi / 2:35 min; 8#: 110.2 psi / 2:38 min.
  4. No abnormal appearance observed on samples after aging.
  5. One sample (6#) was unable to inflate when the aging cycle reached 19 hours.

Test Pictures (描述 / Description):

Image Label
Testing in progress (测试中)
Charging (充电)
E14 high-temperature protection triggered during aging (老化过程出现E14)
Inflation accuracy OK (充气精度OK)

Overall Test Result: At 19 hours of life aging, 1 sample was unable to inflate; 1 sample exhibited an E21 fault code. (测试结果:样品寿命老化到19小时有1个样品出现打不上气的现象,有1个出现E21的现象。)

Conclusion

Field Details
Result For Reference Only (供参考)
Standard Internal Control Standard — 10 H charge-discharge life
Test Conditions 23 °C, 60 % RH; power supply; 13 H logged run
Samples Tested 3 PCS (S0-6#, S0-7#, S0-8#)
Verdict Not Pass / Not Fail — For Reference Only. Samples exceeded the 10 H internal target (13 H logged) but sample 6# lost inflation capability at 19 H and one sample showed E21. Data retained for engineering reference.

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-08-14
Checked By (审核/日期) Zhang Ronggui 2025-08-14
Approved By (核准/日期) Mai Shaoqiang 2025-08-14
Form No. BTK-R-Q142/AO

Frequently Asked Questions

What does the ETENWOLF S0 life cycle test measure?

The test evaluates the reliability of the S0 motor over repeated charge-discharge cycles. Samples run until battery depletion, are recharged, and the cycle repeats for a minimum of 10 hours per the internal control standard. Performance, error codes, and inflation accuracy are recorded throughout.

Why is the ETENWOLF S0 endurance test result classified as For Reference Only rather than Pass or Fail?

The result is classified as For Reference Only because, while all three samples exceeded the 10-hour life target (logging 13 hours), sample 6# lost the ability to inflate when aging reached 19 hours and one sample triggered an E21 fault. The data is retained for engineering review rather than used as a definitive pass/fail quality gate.

What error codes appeared during the S0 aging test?

Two fault codes were observed: E14 (high-temperature protection), which appeared intermittently across samples during the aging run, and E21, which appeared on one sample after extended cycling. Both were logged as part of the test observations.

What was the inflation accuracy of the S0 after 13 hours of aging?

Post-aging inflation accuracy remained close to target for all three samples: S0-6# reached 110.1 psi in 2 minutes 2 seconds; S0-7# reached 110.2 psi in 2 minutes 35 seconds; S0-8# reached 110.2 psi in 2 minutes 38 seconds. Appearance showed no physical defects after aging.

Related Products