ETENWOLF S7 Tire Inflator Noise Test Report (1 m, Front-Face, 3 Samples)

Document Overview

Key Findings All three S7 tire inflator samples produced front-face noise readings between 80.2 dB and 82.7 dB at 1 m distance during powered operation; the result is provided for reference only against an internal standard. Product: ETENWOLF S7 Tire Inflator (Air Pump) Report No.:…

Document type
Certification Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Noise Testing

Key Findings

All three S7 tire inflator samples produced front-face noise readings between 80.2 dB and 82.7 dB at 1 m distance during powered operation; the result is provided for reference only against an internal standard.

  • Product: ETENWOLF S7 Tire Inflator (Air Pump)
  • Report No.: 2025040101
  • Test Date: 2025-04-01
  • Samples: 3 PCS (Units 4#, 6#, 12#)
  • Measurement direction: Front face
  • Microphone distance: 1 m
  • Noise range: 80.2 dB – 82.7 dB
  • Verdict: For Reference Only

Test Overview

Field Detail
Test Type Noise Testing (Reliability Test)
Test Standard Internal Standard
Pass/Fail Criterion N/A — For Reference Only
Report No. 2025040101
Test Date 2025-04-01
Product No. / Name ETENWOLF S7 Tire Inflator (Air Pump)
Model / Specification S7
Manufacturer ETENWOLF
Sample Quantity / No. 3 PCS
Test Purpose Evaluate the noise level of the S7 tire inflator during operation.
Test Conditions Room temperature 23 °C, relative humidity 60 %

Test Equipment & Setup

Item Detail
Test Equipment Sound Level Meter (Noise Meter)
Microphone Distance 1 m horizontal from the front face of the product
Measurement Direction Front face (正面)
Device State During Test Product powered on (operating state)
Ambient Temperature 23 °C
Ambient Humidity 60 % RH

Test Procedure

  1. Pre-test: Verify ambient conditions — temperature 23 °C, relative humidity 60 %. Confirm the sound level meter is calibrated and operational.
  2. Sample placement: Position the S7 unit on a stable surface. Place the microphone at a horizontal distance of 1 m from the front face of the product.
  3. Power on: Switch the product to its normal operating (inflation) state.
  4. Measurement: Record the noise reading in dB from the sound level meter while the unit is running.
  5. Repeat: Perform the measurement for each of the three samples (4#, 6#, 12#) under identical conditions.
  6. Post-test: Power off all samples. Document all readings in the test record.
  7. Acceptance Criteria: No numeric pass/fail threshold defined — results are recorded for reference only per internal standard.

Test Data & Results

Unit No. (编号) Direction (方向) Microphone Distance (距离麦克风距离) Noise (dB) (噪音)
4# Front (正面) 1 m 80.2
6# Front (正面) 1 m 82.7
12# Front (正面) 1 m 81.7

Observations: All three units operated normally during testing. Noise readings ranged from 80.2 dB to 82.7 dB, with unit 6# producing the highest reading and unit 4# the lowest. The spread of 2.5 dB across units is within a typical unit-to-unit variation band for this product class. No abnormal sounds or mechanical anomalies were noted. Results are recorded for reference only; no numeric pass/fail limit is defined under the applicable internal standard.

Conclusion

Parameter Detail
Test Item Noise Level (Front Face, 1 m)
Standard Applied Internal Standard
Test Conditions 23 °C, 60 % RH; microphone at 1 m horizontal from front face; product powered on
Samples Tested 3 PCS — Units 4#, 6#, 12#
Results (dB) 4# → 80.2 dB | 6# → 82.7 dB | 12# → 81.7 dB
Verdict For Reference Only (供参考)

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-04-01
Checked By (审核/日期) Zhang Ronggui 2025-04-01
Approved By (核准/日期) Mai Shaoqiang 2025-04-01
Form / Report No. 2025040101

Frequently Asked Questions

How loud is the ETENWOLF S7 tire inflator during operation?

During powered inflation, the S7 produces a front-face noise level of approximately 80.2 – 82.7 dB measured at 1 m distance. This is typical for a compact high-pressure tire inflator in its class.

What test standard was used for the S7 noise test?

The S7 noise test was conducted against ETENWOLF’s internal standard. No published external standard (such as IEC or ISO) was applied, so the results are recorded for reference only rather than as a formal pass/fail certification.

How was the noise level measured for the S7?

A sound level meter (noise meter) was positioned at a horizontal distance of 1 m from the front face of the S7 unit. The product was powered on in its normal operating state during measurement. Ambient conditions were 23 °C and 60 % relative humidity.

Did the ETENWOLF S7 pass the noise test?

Because the test uses an internal standard with no defined numeric pass/fail threshold, the results are classified as for reference only. All three samples functioned normally and produced consistent readings, confirming stable acoustic performance across units.