FCC-SDOC Certification Report for ETENWOLF S3 Cordless Tire Inflator – WTH25H07183671E

Document Overview

Document Overview This FCC-SDOC (Supplier’s Declaration of Conformity) certification report validates electromagnetic compatibility compliance for the ETENWOLF S3 cordless tire inflator. The document was issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited testing laboratory located in Shenzhen, Guangdong, China. Report Reference Number:…

Document type
User Manual
Prepared by
Michelle Torres
Published
Last reviewed
Topics
North America: FCC / UL

Document Overview

This FCC-SDOC (Supplier’s Declaration of Conformity) certification report validates electromagnetic compatibility compliance for the ETENWOLF S3 cordless tire inflator. The document was issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited testing laboratory located in Shenzhen, Guangdong, China.

Report Reference Number: WTH25H07183671E

Report Form Number: HCT/RF-23-21

Date of Issue: July 22, 2025

Testing Period: July 14-16, 2025

Sample Receipt Date: July 11, 2025

The certification scope covers conducted and radiated emissions testing to ensure the device complies with FCC CFR 47 Part 15 Subpart B requirements for unintentional radiators.

Product Information

Product Name: Inflator Pump / Cordless Tire Inflator

Model Number: S3

Applicant: Guangdong Bestek Technology Co., LTD

Manufacturer: Guangdong Bestek Technology Co., LTD

Manufacturing Location: No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China

The ETENWOLF S3 is a portable electric inflator pump designed for automotive tire inflation and other air pressure applications. As an electronic device with electrical components, it must comply with FCC regulations governing electromagnetic emissions to prevent interference with radio communications and other electronic equipment.

The device was evaluated in its typical operating configuration to ensure real-world compliance with federal emissions standards applicable to consumer electronic products marketed in the United States.

Key Details

The FCC certification testing evaluated the S3 inflator pump across multiple electromagnetic compatibility parameters:

Test Parameter Test Standard Result
Conducted Emission FCC CFR 47 Part 15 Subpart B Pass
Radiated Emission FCC CFR 47 Part 15 Subpart B Pass

Overall Test Result: PASS

Test Report Form: TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01

The testing was conducted in accordance with ANSI C63.4 measurement procedures, which define the methods for measuring radio-noise emissions from digital devices. All measurements were performed at an accredited test facility with calibrated equipment traceable to national standards.

The device demonstrated compliance with applicable limits for both conducted emissions (measured on AC power ports) and radiated emissions (measured at specified distances in an electromagnetically controlled environment).

Standards & Compliance

The certification testing was performed according to the following technical standards and regulatory requirements:

  • FCC CFR 47 Part 15 Subpart B: Federal regulations governing unintentional radiators, which are electronic devices that generate radio frequency energy during operation but are not intended to transmit radio signals. This standard sets maximum emission limits to prevent interference with authorized radio services.
  • ANSI C63.4: American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. This provides the detailed test procedures and measurement techniques.
  • Conducted Emission Limits: Defines maximum allowable electromagnetic interference conducted through power supply lines, typically measured from 150 kHz to 30 MHz.
  • Radiated Emission Limits: Specifies maximum electromagnetic field strength at specified distances from the device, typically measured from 30 MHz to several GHz depending on device characteristics.

The testing laboratory applied appropriate decision rules accounting for measurement uncertainty to determine pass/fail status. The S3 inflator pump met all applicable limits with margin, ensuring robust compliance under normal operating conditions and manufacturing variations.

Validity & Certification Body

Testing Laboratory: Waltek Testing Group HCT (Shenzhen) Co., Ltd.

Laboratory Address: Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China

Contact Information:

  • Tel: 0755-84616666
  • Service Tel: 400-0066-989
  • Email: [email protected]
  • Website: http://www.hct-test.com

Report Prepared By: Snow Zeng

Report Approved By: Tony Wu

Validity: This FCC-SDOC certification remains valid as long as the product design, components, and manufacturing processes remain unchanged. Any modifications to the device that could affect electromagnetic emissions characteristics would require re-evaluation and potentially new certification testing.

Waltek Testing Group HCT (Shenzhen) Co., Ltd. is an accredited electromagnetic compatibility testing laboratory with the facilities and expertise to perform FCC compliance testing according to recognized international standards. The laboratory maintains calibrated test equipment with traceability to national metrology institutes.

Frequently Asked Questions

What does FCC-SDOC certification mean for the ETENWOLF S3?

FCC-SDOC (Supplier’s Declaration of Conformity) certification means the ETENWOLF S3 tire inflator has been tested and verified to comply with FCC Part 15 electromagnetic emission requirements. This certification is legally required to market and sell the device in the United States, ensuring it does not cause harmful interference to radio communications.

Do I need to keep this certification document with my S3 inflator?

End users do not need to retain the full certification report. However, the product should display FCC compliance information (typically an FCC ID or declaration statement) on its label or in the user manual. The manufacturer maintains the test report as evidence of compliance for regulatory purposes.

How long is the FCC certification valid?

The FCC certification for report WTH25H07183671E remains valid indefinitely as long as the S3 product design remains unchanged. If the manufacturer modifies the electronic circuitry, changes components that affect emissions, or alters the device configuration, new testing may be required to verify continued compliance.

What tests were performed during FCC certification?

The S3 inflator underwent conducted emission testing (measuring electromagnetic noise on power lines) and radiated emission testing (measuring electromagnetic fields radiated into space). Both tests ensure the device operates within FCC limits and will not interfere with radio, television, or other electronic equipment.

Related Documents

For comprehensive regulatory compliance documentation of the ETENWOLF S3 cordless tire inflator, you may also be interested in these related certification types:

  • CE Certification (EMC Directive): European Union electromagnetic compatibility certification equivalent to FCC, required for marketing in EU member states.
  • RoHS Compliance Report: Restriction of Hazardous Substances certification verifying the device complies with limits on lead, mercury, cadmium, and other restricted materials.
  • UN38.3 Battery Test: If the S3 contains lithium-ion batteries, UN38.3 certification demonstrates safe transport compliance for air, sea, and ground shipping.
  • UL/ETL Safety Certification: Product safety testing for electrical hazards, fire risks, and mechanical safety under normal and fault conditions.
  • REACH Compliance: European chemical safety regulation ensuring the product does not contain substances of very high concern above threshold limits.
  • KC Certification: Korea Communications Commission certification for electromagnetic compatibility and safety, required for the South Korean market.

ETENWOLF maintains comprehensive compliance documentation to ensure the S3 tire inflator meets regulatory requirements across global markets, providing customers with confidence in product quality, safety, and electromagnetic compatibility.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29