CE-EMC Test Report WTH25H09256003E – HB1 Air Pump Compliance Certification

Document Overview

Document Overview This article covers the official CE Electromagnetic Compatibility (EMC) test report issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. for the ETENWOLF HB1 Air Pump product line. The report reference number is WTH25H09256003E, issued on 2025-10-11 following testing conducted between 2025-09-25 and…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This article covers the official CE Electromagnetic Compatibility (EMC) test report issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. for the ETENWOLF HB1 Air Pump product line. The report reference number is WTH25H09256003E, issued on 2025-10-11 following testing conducted between 2025-09-25 and 2025-09-28. The document type is a CE-EMC Test Report prepared in accordance with EU electromagnetic compatibility directives, covering conducted and radiated emissions as well as immunity requirements applicable to motor-operated household and similar tools.

Field Details
Report Reference No. WTH25H09256003E
Test Report Form No. TRF EN IEC 55014-1: 2021-EMC-001-V01
Internal Form No. HCT/RF-23-21
Issuing Body Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Date Sample Received 2025-09-23
Date of Testing 2025-09-25 to 2025-09-28
Date of Issue 2025-10-11
Overall Test Result Pass

Product Information

The equipment under test (EUT) is the ETENWOLF HB1 Air Pump, a compact motor-driven inflation tool designed for portable use. The product is manufactured and supplied by Guangdong Bestek Technology Co., Ltd. and marketed globally under the ETENWOLF brand. The applicant and manufacturer share the same registered address in Guangdong Province, China.

Field Details
Product Name Air Pump
Model Numbers PUMP MINI / A3 / HiPUMP (collectively identified as HB1)
Applicant Guangdong Bestek Technology Co., LTD
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Product Category Motor-operated household tool / Portable air pump
Intended Market European Union (CE marking)

Key Details

The CE-EMC assessment for the HB1 Air Pump covered electromagnetic emissions and immunity across multiple test disciplines required under the applicable EU harmonised standards. The testing was carried out over four days, with all measured parameters falling within the permitted limits established by the referenced standards. The following table summarises the key test disciplines and their outcomes.

Test Discipline Standard Applied Result
Conducted Emissions (CE) EN IEC 55014-1:2021 Pass
Radiated Emissions (RE) EN IEC 55014-1:2021 Pass
Immunity Requirements EN IEC 55014-2:2021 Pass
Harmonic Current Emissions EN IEC 61000-3-2:2019+A1:2021 Pass
Voltage Fluctuations & Flicker EN 61000-3-3:2013+A2:2021 Pass

All five test categories returned a Pass result, confirming that the HB1 Air Pump meets the EU EMC Directive requirements and is eligible for CE marking on the basis of electromagnetic compatibility performance.

Standards & Compliance

The test was conducted against the following EU harmonised standards, which constitute the normative framework for CE-EMC compliance for motor-operated tools and appliances. Compliance with these standards provides presumption of conformity with the EU EMC Directive 2014/30/EU.

  • EN IEC 55014-1:2021 — Electromagnetic disturbances from household appliances, electric tools, and similar apparatus. Part 1: Emission. This standard specifies limits and test methods for conducted and radiated disturbances in the frequency range 9 kHz to 400 GHz.
  • EN IEC 55014-2:2021 — Electromagnetic disturbances from household appliances, electric tools, and similar apparatus. Part 2: Immunity. Covers immunity requirements for the same product category.
  • EN IEC 61000-3-2:2019+A1:2021 — Limits for harmonic current emissions (equipment input current ≤16 A per phase). Ensures that the product does not inject excessive harmonic currents into the public low-voltage supply network.
  • EN 61000-3-3:2013+A2:2021 — Limitation of voltage changes, voltage fluctuations, and flicker in public low-voltage supply systems (equipment with rated current ≤16 A per phase, not subject to conditional connection).

The test report form number TRF EN IEC 55014-1: 2021-EMC-001-V01 indicates that the laboratory used a controlled and version-tracked test procedure template aligned with the current edition of the standard.

Validity & Certification Body

The report was prepared and issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., a recognised third-party testing laboratory operating within the Waltek Testing Group network. The laboratory is located at Building B, Tianji Industrial Park, 1/F., 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China.

Field Details
Laboratory Name Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Laboratory Address Building B, Tianji Industrial Park, No.30-9, Laiyin Road, Longgang District, Shenzhen, Guangdong, China
Telephone 0755-84616666
Service Hotline 400-0066-989
Email [email protected]
Report Prepared By Snow Zeng
Report Approved By Tony Wu
Date of Issue 2025-10-11
Total Report Pages 51

CE-EMC test reports of this type are typically valid as supporting technical documentation for the Declaration of Conformity for the duration of the product’s market availability, provided no hardware or firmware changes are made to the EUT that could affect its electromagnetic characteristics. Any significant design change would require re-testing.

Frequently Asked Questions

What does CE-EMC certification mean for the HB1 Air Pump?

CE-EMC certification confirms that the HB1 Air Pump complies with the EU Electromagnetic Compatibility Directive (2014/30/EU). This means the product neither generates electromagnetic interference beyond permitted limits nor is it unduly susceptible to interference from other devices. It is a mandatory requirement for placing the product on the European market.

Which standards were used to test the HB1 Air Pump for CE-EMC compliance?

The HB1 Air Pump was tested against four harmonised EU standards: EN IEC 55014-1:2021 (emissions), EN IEC 55014-2:2021 (immunity), EN IEC 61000-3-2:2019+A1:2021 (harmonic current emissions), and EN 61000-3-3:2013+A2:2021 (voltage fluctuations and flicker). All tests returned a Pass result.

Who conducted the CE-EMC testing for the HB1 Air Pump?

Testing was conducted by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an independent third-party test laboratory based in Shenzhen, Guangdong, China. The report reference number is WTH25H09256003E, issued on 2025-10-11 and prepared by Snow Zeng, approved by Tony Wu.

Is the HB1 Air Pump safe to use with European electrical systems?

Yes. The CE-EMC test results confirm that the HB1 Air Pump operates within the harmonic current and voltage fluctuation limits defined for connection to European public low-voltage supply networks, as verified under EN IEC 61000-3-2 and EN 61000-3-3.

Related Documents

For a complete regulatory compliance picture of the HB1 Air Pump, the following related certification and test documents are typically required or recommended alongside the CE-EMC test report:

  • CE-LVD (Low Voltage Directive) Test Report — Covers electrical safety under EU Directive 2014/35/EU, typically tested to EN 62368-1 or EN 60335 series for motor-operated appliances.
  • CE Declaration of Conformity (DoC) — The manufacturer’s formal declaration citing all applicable directives and harmonised standards, required for CE marking. References the EMC test report WTH25H09256003E as supporting evidence.
  • RoHS Compliance Report — Confirms restriction of hazardous substances (lead, mercury, cadmium, etc.) per EU Directive 2011/65/EU, relevant for all electrical and electronic equipment sold in the EU.
  • REACH SVHC Declaration — Substance of Very High Concern assessment under EU REACH Regulation (EC) No 1907/2006.
  • UN 38.3 Battery Test Report — If the HB1 Air Pump includes a rechargeable lithium battery, a UN 38.3 transport safety test report is required for shipping compliance.
  • FCC Part 15 Test Report — Required for sale in the United States market, covering similar emissions and immunity requirements under FCC regulations.
  • KC Certification (Korea) — Required for the South Korean market under the KC EMC framework.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30
Document Page 31
Document Page 32
Document Page 33
Document Page 34
Document Page 35
Document Page 36
Document Page 37
Document Page 38
Document Page 39
Document Page 40
Document Page 41
Document Page 42
Document Page 43
Document Page 44
Document Page 45
Document Page 46
Document Page 47
Document Page 48
Document Page 49
Document Page 50
Document Page 51