Document Overview

Document Overview This article presents the FCC electromagnetic compatibility (EMC) test report for the ETENWOLF P600 Electric Balloon Pump. The report was issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party electromagnetic compatibility testing laboratory located in Longgang District, Shenzhen, Guangdong, China.…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
Sports & Recreation

Document Overview

This article presents the FCC electromagnetic compatibility (EMC) test report for the ETENWOLF P600 Electric Balloon Pump. The report was issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party electromagnetic compatibility testing laboratory located in Longgang District, Shenzhen, Guangdong, China.

  • Reference No.: WTH25H11294796E
  • Test Report Form No.: TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01
  • Internal Lab Reference: HCT/RF-23-21
  • Document Type: FCC EMC Test Report
  • Date of Sample Receipt: 2025-11-10
  • Test Period: 2025-11-10 to 2025-11-18
  • Date of Issue: 2025-11-20
  • Overall Test Result: Pass

The report scope covers conducted emission and radiated emission measurements in accordance with FCC CFR 47 Part 15 Subpart B, confirming that the product does not cause harmful electromagnetic interference in the frequency ranges evaluated.

Product Information

The Equipment Under Test (EUT) evaluated in this report is the ETENWOLF P600 Electric Balloon Pump, a consumer-grade electric inflation device designed for rapid and efficient balloon inflation.

Field Detail
EUT Name Electric Balloon Pump
Model No. P600
Trade Mark N/A
Applicant Guangdong Bestek Technology Co., LTD
Manufacturer Guangdong Bestek Technology Co., LTD
Applicant Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Operating Mode Motor-driven electric pump (Mo)

The P600 is designed as an unintentional radiator under the FCC definition, meaning it does not intentionally generate or emit radio frequency energy for communication purposes. EMC compliance is therefore assessed under the unintentional radiator rules of Part 15 Subpart B.

Key Details

The test report covers two major EMC test categories: Conducted Emission and Radiated Emission. The following table summarises the test sections, their scope, and outcomes.

Test Section Scope Frequency Range Result
Conducted Emission Measures RF energy conducted back onto the AC power line from the EUT 0.15 MHz – 30 MHz Pass
Radiated Emission Measures RF energy radiated from the EUT and its associated cables 30 MHz – 1 GHz (and above as required) Pass

Key procedural details documented within the report include:

  • EUT Exercise Software: The pump was operated in its normal motor-driven mode during all tests to reproduce worst-case emission conditions.
  • Equipment Modifications: No modifications were made to the EUT prior to or during testing.
  • Measurement Uncertainty: Declared for both conducted and radiated emission sections in accordance with lab accreditation requirements.
  • Decision Rule: A decision rule was applied to measurement results, accounting for measurement uncertainty when determining pass/fail status against FCC limits.
  • Corrected Amplitude & Margin Calculation: Documented in Section 4.6 of the report, confirming measured emission levels with margin below the applicable FCC limits.

Test data, instrument setup records, EUT setup photographs, and test setup photographs are included as Appendix A and Appendix B within the original report document.

Standards & Compliance

The ETENWOLF P600 was tested against the following regulatory standard:

Standard Title Applicability
FCC CFR 47 Part 15 Subpart B Unintentional Radiators – Conducted and Radiated Emission Limits Primary applicable standard; governs both conducted and radiated emission limits for consumer electronic devices sold in the United States

The test report form used was TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01, the standardised reporting template aligned with FCC requirements for unintentional radiator test reports.

Compliance with FCC Part 15 Subpart B is mandatory for any digital device or unintentional radiator marketed or sold in the United States. A passing result confirms that the P600 meets the conducted and radiated emission limits set by the FCC, protecting other electronic equipment and radio communications from harmful interference.

Validity & Certification Body

The test report was prepared and issued by:

  • Laboratory: Waltek Testing Group HCT (Shenzhen) Co., Ltd.
  • Address: Building B, Tianji Industrial Park, 1/F., 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
  • Tel: 0755-84616666
  • Service Tel: 400-0066-989
  • Email: [email protected]
  • Prepared by: Snow Zeng
  • Approved by: Tony Wu

The report reference number WTH25H11294796E uniquely identifies this test record. The report was issued on 2025-11-20. FCC test reports of this type do not carry an independent expiry date; however, the report remains valid as long as the product design, components, and construction remain unchanged from the tested sample. Any material design change would require re-evaluation.

Waltek Testing Group HCT (Shenzhen) Co., Ltd. is an accredited EMC and safety testing laboratory operating under ISO/IEC 17025 quality management principles, providing testing services recognised by international regulators including the FCC.

Frequently Asked Questions

Q: What does a passing FCC CFR 47 Part 15 Subpart B result mean for the ETENWOLF P600?

A: It means the ETENWOLF P600 Electric Balloon Pump was independently tested and confirmed to emit electromagnetic energy at levels below the limits set by the FCC for both conducted and radiated emissions. The product will not cause harmful interference to other electronic devices or radio communications when used as intended.

Q: What is the report reference number for the P600 FCC test?

A: The official FCC EMC test report reference number is WTH25H11294796E, issued on 2025-11-20 by Waltek Testing Group HCT (Shenzhen) Co., Ltd. The internal lab reference is HCT/RF-23-21.

Q: Which emission tests were conducted on the P600?

A: Two types of emission tests were conducted: Conducted Emission (measuring RF energy fed back onto the power line, 0.15 MHz to 30 MHz) and Radiated Emission (measuring electromagnetic energy radiated into the environment, 30 MHz and above). Both tests returned a Pass result.

Q: Does FCC Part 15 Subpart B certification allow the P600 to be sold in the United States?

A: Compliance with FCC CFR 47 Part 15 Subpart B is a regulatory requirement for unintentional radiators marketed in the United States. A passing result and the associated test report support the Supplier’s Declaration of Conformity (SDoC) or FCC authorisation filing, enabling lawful sale and distribution of the P600 in the US market.

Related Documents

The following certification and compliance documents are typically required or recommended for a consumer electric inflation product such as the ETENWOLF P600:

  • CE EMC Declaration (EN 55032 / EN 55035) — Required for sale in the European Union; covers electromagnetic emissions and immunity for multimedia equipment.
  • CE Low Voltage Directive (LVD) / EN 62368-1 Safety Report — Required for EU market entry; covers electrical safety for audio/video and IT equipment.
  • RoHS Compliance Report — Confirms restriction of hazardous substances (lead, mercury, cadmium, etc.) in accordance with EU Directive 2011/65/EU.
  • REACH SVHC Declaration — Confirms that substances of very high concern are below threshold levels as required by EU REACH Regulation (EC) No 1907/2006.
  • KC Certification (KC Mark) — Required for the South Korean market; covers electromagnetic compatibility and electrical safety.
  • UN 38.3 Test Report — Applicable if the product variant includes a lithium battery; required for safe transport classification.
  • California Proposition 65 Compliance Statement — Recommended for US retail distribution, confirming compliance with California chemical exposure warning requirements.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22