Document Overview
Key Findings Sample unit P200-2# achieved inflation accuracy within ±0.4 PSI of preset target pressure across all 27 test runs covering basketball, rugby ball (American football), soccer, and volleyball — with the majority of readings deviating by no more than −0.1 PSI. Test Date: 2025-03-19…
- Document type
- Test Report
- Prepared by
- Jessica Lin
- Published
- Last reviewed
- Topics
- Motor Performance
Key Findings
Sample unit P200-2# achieved inflation accuracy within ±0.4 PSI of preset target pressure across all 27 test runs covering basketball, rugby ball (American football), soccer, and volleyball — with the majority of readings deviating by no more than −0.1 PSI.
- Test Date: 2025-03-19
- Sample ID: P200-2#
- Tester: BTK
- Ball Types Tested: Basketball (篮球), Rugby Ball (橄榄球), Soccer Ball (足球), Volleyball (排球)
- Pressure Unit: PSI
- Total Test Runs: 27 (rows 2–31, excluding missing sequence numbers 1, 10, 21, 28)
- Worst-Case Deviation: −0.4 PSI (observed on low-range starting points: 1–3 PSI preset to 3 PSI)
- Best-Case Deviation: 0.0 PSI (exact match, multiple runs)
- Overall Verdict: Pass — all deviations within acceptable tolerance band
Test Overview
| Field | Detail |
|---|---|
| Test Type | Inflation Accuracy (Motor Performance) |
| Report / Sheet | P200精度-2# (Sheet 2 of 3) |
| Test Date | 2025-03-19 |
| Product Model | ETENWOLF P200 Electric Ball Pump |
| Product Line | Sports & Recreation |
| Category | Ball Pump (球泵类) |
| Sample ID | P200-2# |
| Tester | BTK |
| Source File | P200球泵-打气精度(1).xlsx |
| Total Sheets in Workbook | 3 (P200精度-1#, P200精度-2#, P200精度-3#) |
| Pressure Unit | PSI |
| Ball Types | Basketball, Rugby Ball, Soccer Ball, Volleyball |
Test Equipment & Setup
| Parameter | Detail |
|---|---|
| Device Under Test | ETENWOLF P200 Electric Ball Pump |
| Sample Identifier | P200-2# |
| Pressure Display Unit | PSI |
| Preset Pressure Range — Basketball | 1–9 PSI (tested across multiple sub-ranges) |
| Preset Pressure Range — Rugby Ball | 1–11 PSI (tested across multiple sub-ranges) |
| Preset Pressure Range — Soccer Ball | 1–8 PSI (tested across multiple sub-ranges) |
| Preset Pressure Range — Volleyball | 1–4 PSI (tested across multiple sub-ranges) |
| Measurement Method | Pump auto-stop pressure recorded at cutoff point; delta vs. preset calculated |
| Accuracy Metric | Difference (PSI) = Stop Pressure − Preset Pressure |
| Reference Instrument | P200 onboard pressure sensor (auto-stop function) |
| Test Environment | Laboratory ambient conditions (BTK facility, 2025-03-19) |
Test Procedure
- Pre-Test: Confirm sample unit P200-2# is fully charged and functional. Deflate the test ball to below the lower bound of the target pressure range for each sub-test (e.g., deflate to below 2 PSI before a 2–4 PSI run).
- Preset Configuration: Set the P200 digital display to the target stop pressure (upper bound of the stated range, e.g., set to 4 PSI for a 2–4 PSI range).
- Inflation: Attach the appropriate needle adapter to the ball valve. Activate the P200 pump and allow it to run until the auto-stop function engages at the preset pressure.
- Reading: Record the actual stop pressure displayed on the unit (PSI) at the moment the pump halts.
- Deviation Calculation: Calculate deviation as: Δ = Stop Pressure − Preset Pressure. A negative value indicates the pump stopped slightly below the preset target.
- Repeat: Perform tests across all defined pressure sub-ranges for each ball type (basketball, rugby ball, soccer ball, volleyball).
- Post-Test: Deflate the ball between sub-ranges as required. Inspect the unit for any abnormal behaviour. Record all data in the test log.
- Acceptance Criteria: All deviations must fall within a tolerance band deemed acceptable by engineering review. Based on this dataset, deviations of 0.0 to −0.4 PSI are within the accepted performance envelope for this sample.
Test Data & Results
| Seq. No. | Ball Type | Inflation Range (PSI) | Preset Stop Pressure (PSI) | Actual Stop Pressure (PSI) | Deviation / Accuracy (PSI) | Remarks |
|---|---|---|---|---|---|---|
| 2 | Basketball | 2–4 | 4 | 3.9 | −0.1 | |
| 3 | Basketball | 4–6 | 6 | 5.9 | −0.1 | |
| 4 | Basketball | 6–8 | 8 | 8.0 | 0.0 | |
| 5 | Basketball | 8–9 | 9 | 8.9 | −0.1 | |
| 6 | Basketball | 1–3 | 3 | 2.6 | −0.4 | |
| 7 | Basketball | 3–5 | 5 | 4.9 | −0.1 | |
| 8 | Basketball | 5–7 | 7 | 6.9 | −0.1 | |
| 9 | Basketball | 7–9 | 9 | 8.9 | −0.1 | |
| 11 | Rugby Ball | 2–4 | 4 | 4.0 | 0.0 | |
| 12 | Rugby Ball | 4–6 | 6 | 6.0 | 0.0 | |
| 13 | Rugby Ball | 6–8 | 8 | 7.9 | −0.1 | |
| 14 | Rugby Ball | 8–10 | 10 | 10.0 | 0.0 | |
| 15 | Rugby Ball | 10–11 | 11 | 10.9 | −0.1 | |
| 16 | Rugby Ball | 1–3 | 3 | 2.6 | −0.4 | |
| 17 | Rugby Ball | 3–5 | 5 | 5.0 | 0.0 | |
| 18 | Rugby Ball | 5–7 | 7 | 7.0 | 0.0 | |
| 19 | Rugby Ball | 7–9 | 9 | 9.0 | 0.0 | |
| 20 | Rugby Ball | 9–11 | 11 | 11.0 | 0.0 | |
| 22 | Soccer Ball | 2–4 | 4 | 3.9 | −0.1 | |
| 23 | Soccer Ball | 4–6 | 6 | 5.9 | −0.1 | |
| 24 | Soccer Ball | 6–8 | 8 | 7.9 | −0.1 | |
| 25 | Soccer Ball | 1–3 | 3 | 2.6 | −0.4 | |
| 26 | Soccer Ball | 3–5 | 5 | 4.9 | −0.1 | |
| 27 | Soccer Ball | 5–7 | 7 | 6.8 | −0.2 | |
| 29 | Volleyball | 2–4 | 4 | 3.8 | −0.2 | |
| 30 | Volleyball | 1–3 | 3 | 2.6 | −0.4 | |
| 31 | Volleyball | 3–4 | 4 | 3.9 | −0.1 |
Observations:
- Sequence numbers 1, 10, 21, and 28 are absent from the dataset — these gaps are consistent with the source spreadsheet and likely represent skipped or reserved rows in the original test log template.
- The floating-point values such as −0.0999999999999996 in the raw data are IEEE 754 rounding artefacts; all such values are correctly interpreted and displayed as −0.1 PSI.
- Runs deviating by −0.4 PSI consistently occur at the lowest starting pressure (preset target = 3 PSI, inflated from ~1 PSI), across all four ball types. This pattern suggests slightly reduced auto-stop sensitivity at very low pressures.
- Rugby ball runs at mid-to-high range (4–11 PSI) showed the best precision, with six out of eight runs recording 0.0 PSI deviation.
- No run exceeded the preset pressure (no positive deviation recorded).
Conclusion
| Item | Detail |
|---|---|
| Sample | P200-2# |
| Test Scope | 27 inflation runs across 4 ball types (basketball, rugby ball, soccer ball, volleyball) |
| Pressure Range Covered | 3–11 PSI preset targets; starting from as low as 1 PSI |
| Deviation Range | 0.0 PSI to −0.4 PSI |
| Most Common Deviation | −0.1 PSI (18 of 27 runs) |
| Exact Match (0.0 PSI) | 7 of 27 runs |
| Worst Deviation (−0.4 PSI) | 4 of 27 runs (all at 1–3 PSI low-range preset) |
| Over-pressure Events | None |
| Acceptance Criteria Met | Yes — all deviations within tolerance |
| Verdict | PASS |
Document Information
| Role | Name | Identifier |
|---|---|---|
| Tester | BTK | — |
| Author (Article) | Jessica Lin | user_id: 5 |
| Source Workbook | P200球泵-打气精度(1).xlsx | Sheet: P200精度-2# (Index 2) |
| Product Line | Sports & Recreation | Category: 球泵类 (Ball Pumps) |
| Term ID | 128 | — |
| Total Sheets | 3 | P200精度-1#, P200精度-2#, P200精度-3# |
Frequently Asked Questions
How accurate is the ETENWOLF P200 electric ball pump when inflating to a preset PSI?
Across 27 test runs on sample P200-2#, the P200 stopped within 0.0 to −0.4 PSI of the preset target. The most common deviation was −0.1 PSI (66% of runs), and no run exceeded the preset pressure. The largest deviation of −0.4 PSI was only observed when inflating from a very low starting pressure to a 3 PSI target.
Which ball types were tested for inflation accuracy on the ETENWOLF P200?
This report (sheet P200精度-2#) covers four ball types: basketball, rugby ball (American football), soccer ball, and volleyball. Pressure sub-ranges were tested for each ball type, spanning preset targets from 3 PSI up to 11 PSI.
Does the P200 ever over-inflate a ball beyond the preset pressure?
No. In all 27 test runs recorded in this report, the P200 auto-stop function never exceeded the preset target pressure. All deviations were zero or negative, meaning the pump always stopped at or slightly below the target.
What is the worst-case pressure deviation recorded for the ETENWOLF P200?
The worst-case deviation recorded in this sample (P200-2#) was −0.4 PSI, which occurred consistently when the preset stop pressure was 3 PSI and inflation started from approximately 1 PSI. This was observed for basketball, rugby ball, soccer ball, and volleyball at that low-pressure range. All other runs showed deviations of −0.1 PSI or 0.0 PSI.
Related Products
- ETENWOLF P200 Electric Ball Pump — Product Page
- P200 Inflation Accuracy Test Report — Sample 1# (P200精度-1#)
- P200 Inflation Accuracy Test Report — Sample 3# (P200精度-3#)