ETENWOLF P400 Electric Balloon Pump Thermal Rise Test Report (B7, 3 Samples)

Document Overview

Key Findings The P400 balloon pump (B7) completed thermal rise testing across 3 samples under continuous operation with both large and small nozzles, with all measurements recorded for reference only. Report No.: 2025041701.0 Test Date: 2025-04-17 Samples: 3 PCS (1#–3#) Ambient Temperature: 33.5 °C Test…

Document type
Test Report
Prepared by
Jessica Lin
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The P400 balloon pump (B7) completed thermal rise testing across 3 samples under continuous operation with both large and small nozzles, with all measurements recorded for reference only.

  • Report No.: 2025041701.0
  • Test Date: 2025-04-17
  • Samples: 3 PCS (1#–3#)
  • Ambient Temperature: 33.5 °C
  • Test Conditions: Room Temp 32 °C, Humidity 60%, Power Source 120 V
  • Peak Motor Temperature: 80.8 °C (Sample B7-3#)
  • Peak Temperature Rise: 47.3 K (Sample B7-3# motor)
  • Verdict: For Reference Only (not a pass/fail determination)

Test Overview

Field Details
Test Type Environmental Testing — Reliability Test (温升 / Thermal Rise)
Test Standard Internal Control Standard (内控标准)
Report No. 2025041701.0
Test Date 2025-04-17
Product No. / Name B7 — Balloon Inflation Pump (P400)
Manufacturer ETENWOLF
Sample Quantity / No. 3 PCS — 1#, 2#, 3#
Test Purpose Evaluate the operating temperature of the samples
Test Conditions Room Temp: 32 °C, Humidity: 60%, Power Source: 120 V
Ambient Temp (Recorded) 33.5 °C

Test Equipment & Setup

Parameter Value
Power Source Voltage 120 V
Ambient Temperature (Set) 32 °C
Relative Humidity 60%
Ambient Temperature (Recorded during test) 33.5 °C
Nozzle Configurations Tested Large nozzle (大气嘴) and Small nozzle (小气嘴)
Measurement Points Motor (马达), Internal air duct (内部风道), Large nozzle (大气嘴), Small nozzle (小气嘴)
Test Reference Standard / (Internal control standard — 内控标准)

Test Procedure

  1. Pre-Test: Confirm ambient temperature and humidity conditions (32 °C, 60% RH). Record baseline ambient temperature. Prepare 3 samples (B7-1#, B7-2#, B7-3#) and connect to 120 V power source.
  2. Procedure: Operate each unit continuously with both large and small nozzles attached. Monitor and record temperatures at four measurement points — motor, internal air duct, large nozzle, and small nozzle — until readings stabilize (temperature rise plateau reached).
  3. Post-Test: Record the maximum temperature (°C) and temperature rise (K) at each measurement point for each sample. Ambient temperature at time of test is noted per sample.
  4. Acceptance Criteria: No formal pass/fail threshold specified (internal reference standard). Results are recorded for reference only (供参考).

Test Data & Results

Sample No. Measurement Motor Temp (马达温度) Internal Air Duct Temp (内部风道温度) Large Nozzle (大气嘴) Small Nozzle (小气嘴) Ambient Temp (环境温度) °C
B7-1# Max Temperature (°C) 75.2 74.3 69.1 71.2 33.5
Temperature Rise (K) 41.7 40.8 35.6 37.7
B7-2# Max Temperature (°C) 80.1 76.5 75.6 72.4 33.5
Temperature Rise (K) 46.6 43.0 42.1 38.9
B7-3# Max Temperature (°C) 80.8 76.8 72.9 74.3 33.5
Temperature Rise (K) 47.3 43.3 39.4 40.8

Note: Detailed time-series data is provided in the attached data sheet (测试数据见附表). Temperature rise (K) values are calculated relative to the recorded ambient temperature of 33.5 °C.

Conclusion

Field Details
Result For Reference Only (■供参考 / For reference only)
Standard Applied Internal Control Standard (内控标准)
Test Conditions 32 °C room temp, 60% RH, 120 V power source; recorded ambient 33.5 °C
Samples Tested 3 PCS — B7-1#, B7-2#, B7-3#
Verdict No formal pass/fail threshold defined. Peak motor temperature 80.8 °C and maximum temperature rise 47.3 K observed on B7-3#. All data recorded for engineering reference.

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-04-17
Checked By (审核/日期) Zhang Ronggui 2025-04-17
Approved By (审核/日期) Mai Shaoqiang 2025-04-17
Source File B7-汽球充气泵-温升报告-2025.4.17.xls
Sheet 温升报告 (Sheet 1 of 2)
Report No. 2025041701.0

Frequently Asked Questions

What does temperature rise (K) mean in this test?

Temperature rise, expressed in Kelvin (K), is the difference between the maximum measured temperature at a given point and the ambient temperature recorded during the test (33.5 °C in this case). It isolates the heat generated by the product itself, independent of the starting ambient condition, making it a reliable metric for comparing thermal performance across different environments.

Why are the results marked “For Reference Only” rather than Pass or Fail?

The test was conducted against an internal control standard with no defined numerical pass/fail threshold for temperature rise. This is common in early-stage engineering validation or design characterization testing, where the goal is to map thermal behavior rather than certify compliance against an external standard such as IEC or UL.

Why were both large and small nozzles tested simultaneously?

Different nozzle sizes affect airflow restriction and therefore motor load. Running both configurations ensures the thermal profile captures the worst-case operating scenario. Results at the large and small nozzle measurement points reflect how nozzle geometry influences heat distribution along the airflow path.

How do the three samples compare?

B7-1# ran coolest overall, with a peak motor temperature of 75.2 °C and motor temperature rise of 41.7 K. B7-2# and B7-3# were close, peaking at 80.1 °C and 80.8 °C respectively. Sample-to-sample variation of approximately 5.6 °C at the motor is within a normal range for this class of product and likely reflects minor manufacturing tolerances in motor winding and housing fit.

Related Products

Explore the P400 balloon pump and related documentation:

Other test sheets from the same report file (B7-汽球充气泵-温升报告-2025.4.17.xls):

  • 温升数据 — Thermal Rise Raw Data Sheet (sibling sheet 2 of 2)