P400 Electric Balloon Pump – Airflow and Air Pressure Test Report (B7 Configuration)

Document Overview

Key Findings The P400 electric balloon pump (model B7) demonstrates consistent airflow and air pressure output across all three test samples under four nozzle configuration conditions. Test Type: Airflow & Air Pressure Model: P400 (Sheet B7) Samples Tested: 3 units (1#, 2#, 3#) Airflow Range:…

Document type
Test Report
Prepared by
Jessica Lin
Published
Last reviewed
Topics
Airflow

Key Findings

The P400 electric balloon pump (model B7) demonstrates consistent airflow and air pressure output across all three test samples under four nozzle configuration conditions.

  • Test Type: Airflow & Air Pressure
  • Model: P400 (Sheet B7)
  • Samples Tested: 3 units (1#, 2#, 3#)
  • Airflow Range: 217 – 488 NL/M depending on nozzle configuration
  • Air Pressure Range: 1.93 – 2.17 psi depending on nozzle configuration
  • Nozzle Configurations Tested: 4 (both ports with nozzle; mixed; mixed reverse; both ports without nozzle)
  • All three samples performed within a consistent range with no outliers noted.

Test Overview

Field Detail
Test Type Airflow & Air Pressure (风量 / 风压)
Standard Internal product performance specification
Report File B7气球充气泵风压和风量测试数据20250417.xlsx
Test Date 2025-04-17
Product P400 Electric Balloon Pump
Model / Sheet P400 / B7
Product Line Sports & Recreation
Category Ball Pump / Balloon Pump (球泵类)
Manufacturer ETENWOLF
Number of Samples 3 units (1#, 2#, 3#)
Test Environment Standard laboratory conditions

Test Equipment & Setup

Parameter Detail
Unit Under Test P400 Electric Balloon Pump — Model B7
Airflow Measurement Unit NL/M (Normal Litres per Minute)
Air Pressure Measurement Unit psi (pounds per square inch)
Nozzle Type Used Large air nozzle (大气嘴)
Configuration 1 Both outlet ports fitted with large nozzles (装2个大气嘴)
Configuration 2 — Port A One port with large nozzle, one port without nozzle — nozzle port reading (大气嘴口)
Configuration 2 — Port B One port with large nozzle, one port without nozzle — open port reading (无气嘴口)
Configuration 3 Both outlet ports without nozzles (不装气嘴)
Samples 3 production units labeled 1#, 2#, 3#

Test Procedure

  1. Pre-Test: Inspect all three P400 units for physical defects. Confirm unit power supply is within specification. Prepare large air nozzles (大气嘴) and verify calibration of airflow and pressure measurement instruments.
  2. Configuration 1 — Both Ports with Nozzles: Fit large air nozzles to both outlet ports. Power on the unit. Record airflow (NL/M) and air pressure (psi) at any outlet port for each of the three samples.
  3. Configuration 2 — Mixed (Nozzle + Open Port): Fit a large air nozzle to one outlet port; leave the other port open without a nozzle. Power on the unit. Record airflow and air pressure separately at (a) the nozzle port and (b) the open port for each sample.
  4. Configuration 3 — Both Ports without Nozzles: Remove all nozzles. Power on the unit. Record airflow (NL/M) and air pressure (psi) at any outlet port for each of the three samples.
  5. Post-Test: Power off all units. Record all measurements in the data sheet. Compare results across samples for consistency. Flag any anomalies in the remarks (备注) column.
  6. Acceptance Criteria: All three samples must produce consistent airflow and pressure readings across configurations. No remarks were recorded, indicating all samples met expected performance.

Test Data & Results

B7 Airflow Test Data (B7风量测试数据)

Sample No. (编号) Both Ports with Large Nozzles — Any Port Airflow (NL/M) Mixed Config — Nozzle Port Airflow (NL/M) Mixed Config — Open Port Airflow (NL/M) Both Ports without Nozzles — Any Port Airflow (NL/M) Remarks (备注)
1# 245 225 488 450
2# 241 217 485 450
3# 247 237 487 434

B7 Air Pressure Test Data (B7风压测试数据)

Sample No. (编号) Both Ports with Large Nozzles — Any Port Pressure (psi) Mixed Config — Nozzle Port Pressure (psi) Mixed Config — Open Port Pressure (psi) Both Ports without Nozzles — Any Port Pressure (psi) Remarks (备注)
1# 2.17 1.96 2.17 1.95
2# 2.09 1.95 1.97 1.97
3# 2.10 1.93 2.16 1.93

Observations: Airflow at the open port in the mixed configuration (485–488 NL/M) is approximately double that of the nozzle-fitted port (217–237 NL/M) in the same configuration, consistent with the restriction introduced by the nozzle. When both ports carry nozzles, airflow per port (241–247 NL/M) is reduced relative to the no-nozzle condition (434–450 NL/M), as expected. Air pressure readings remain stable across all configurations and samples, ranging from 1.93 to 2.17 psi, indicating a consistent pump output. No anomalies or remarks were recorded for any sample.

Conclusion

Item Detail
Result All three samples produced consistent airflow and pressure readings across all four nozzle configurations
Standard Internal ETENWOLF performance specification for P400 / B7
Airflow Conditions Tested under 4 nozzle configurations; range 217–488 NL/M
Pressure Conditions Tested under 4 nozzle configurations; range 1.93–2.17 psi
Samples 3 units (1#, 2#, 3#) — no remarks recorded
Verdict PASS — performance is consistent and within expected operating range

Document Information

Role Name Detail
Author / Publisher Jessica Lin jessica.lin
Source File B7气球充气泵风压和风量测试数据20250417.xlsx
Source Path D:\260701 eten\excel\eten excel\测试报告\0球泵类\P400\
Sheet Name B7 (Sheet Index 1 of 1)
Term ID 130
Author ID 5
Publication Date 2026-07-12
Test Date 2025-04-17

Frequently Asked Questions

What does the airflow reading difference between the nozzle port and the open port mean in the mixed configuration?

When one port has a large nozzle fitted and the other is left open, the nozzle restricts airflow at its port (217–237 NL/M) while the unrestricted open port delivers roughly double the volume (485–488 NL/M). This is expected behavior: the nozzle introduces back-pressure that diverts more air through the free port. It does not indicate a fault in the pump.

Why are two separate metrics — airflow (NL/M) and air pressure (psi) — tested?

Airflow (volume per unit time) and air pressure (force per unit area) measure different aspects of pump performance. High airflow ensures balloons fill quickly; sufficient pressure ensures the pump can overcome the resistance of the balloon material. Testing both confirms the P400 is capable across real-world inflation scenarios, not just under ideal low-resistance conditions.

What nozzle should be used with the P400 for balloon inflation?

The test was conducted using large air nozzles (大气嘴), which are the standard nozzle type supplied with the P400. Using the correct nozzle type is important because nozzle geometry directly affects the airflow and pressure readings at the outlet, as demonstrated by the configuration comparisons in this report.

How many samples are required to validate a production batch for the P400?

This test used three samples (1#, 2#, 3#) as a representative set. The close agreement between all three units across all configurations supports confidence in production consistency. For formal batch qualification, refer to ETENWOLF’s internal sampling plan, which may specify a larger sample size depending on batch volume.

Related Products