Document Overview
Key Findings The ETENWOLF P300 Smart Ball Pump was subjected to a 6-face drop test from 100 cm height; 1 out of 3 samples exhibited a display missing pixels (缺画) on power-up after the drop sequence, resulting in a Fail verdict. Product: P300 Smart Ball…
- Document type
- Test Report
- Prepared by
- Jessica Lin
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF P300 Smart Ball Pump was subjected to a 6-face drop test from 100 cm height; 1 out of 3 samples exhibited a display missing pixels (缺画) on power-up after the drop sequence, resulting in a Fail verdict.
- Product: P300 Smart Ball Pump
- Test Height: 100 cm
- Drop Faces: 6 (one drop per face)
- Sample Size: 3 PCS
- Failure Mode: 1 PCS showed missing display pixels on power-up post-drop
- Charging Function: Normal on all samples
- Accuracy: Normal on all samples
- Overall Verdict: FAIL
Test Overview
| Field | Details |
|---|---|
| Test Type | Drop Test (Mechanical Reliability) |
| Report Number | 2025060501.0 |
| Date | 2025-06-05 |
| Product Name | P300 Smart Ball Pump (P300-球泵) |
| Manufacturer | BTK |
| Surface Treatment | Not specified |
| Sample Quantity | 3 PCS |
| Test Reason | New Product (■新产品 New product) |
| Test Objective | Evaluate the product’s anti-drop impact capability and verify finished-product reliability by simulating drop conditions. |
| Laboratory Temperature | 22 °C |
| Laboratory Humidity | 55% RH |
Test Equipment & Setup
| Parameter | Details |
|---|---|
| Instrument Name | Single-Arm Drop Testing Machine (单臂跌落试验机) |
| Test Height | 100 cm |
| Number of Drops | 6 faces (6 drops total) |
| Sample Weight | Not recorded in report |
| Test Class / Level | Not specified |
| Acceptance Criteria | Product appearance and function normal; housing must not crack (产品外观功能正常,外壳无开裂) |
Test Procedure
- Pre-Test Inspection: Verify all 3 PCS samples show no defects before testing. Confirm display operates correctly on power-up (no missing pixels). Document pre-test condition with photographs using the single-arm drop testing machine and power controller.
- Environment Check: Confirm laboratory temperature is 22 °C and humidity is 55% RH before commencing drops.
- Drop Sequence: Set the single-arm drop testing machine to a drop height of 100 cm. Subject each sample to 6 consecutive drops, one per face (Face 1 through Face 6), in accordance with the 6-face drop protocol.
- Post-Drop Functional Check: Power on each sample after completing all 6 drops. Check display for missing pixels or anomalies. Verify charging function. Verify measurement accuracy. Inspect housing for cracks or structural damage.
- Documentation: Record results per sample. Photograph pre-drop condition, the drop machine setup, the power controller, and post-drop results for each of the 6 faces.
Acceptance Criteria: All samples must power on with full display function, no housing cracks, and normal charging and accuracy performance. Any deviation constitutes a Fail.
Test Data & Results
| Check Point | Sample 1 | Sample 2 | Sample 3 |
|---|---|---|---|
| Pre-drop display condition | Normal (no missing pixels) | Normal (no missing pixels) | Normal (no missing pixels) |
| Post-drop display on power-up | Missing pixels on power-up (缺画) | Normal | Normal |
| Charging function | Normal | Normal | Normal |
| Measurement accuracy | Normal | Normal | Normal |
| Housing cracks | None observed | None observed | None observed |
| Other anomalies | None | None | None |
Drop Face Records:
| Drop No. | Face | Observation |
|---|---|---|
| 1st Drop (第一次) | Face 1 | No anomaly noted during drop |
| 2nd Drop (第二次) | Face 2 | No anomaly noted during drop |
| 3rd Drop (第三次) | Face 3 | No anomaly noted during drop |
| 4th Drop (第四次) | Face 4 | No anomaly noted during drop |
| 5th Drop (第五次) | Face 5 | No anomaly noted during drop |
| 6th Drop (第六次) | Face 6 | No anomaly noted during drop |
Summary of Test Results (测试结果): After the 100 cm 6-face drop test, 1 out of 3 P300 samples exhibited missing display pixels on power-up (开机缺画). No other anomalies were observed across all three samples. Charging and accuracy functions remained normal.
Conclusion
| Field | Details |
|---|---|
| Result | FAIL (■不合格 Fail) |
| Standard / Criteria | Product appearance and function normal; housing must not crack after 6-face drop from 100 cm |
| Test Conditions | 100 cm drop height, 6 faces, 22 °C / 55% RH |
| Samples Tested | 3 PCS |
| Failure Detail | 1 PCS showed missing pixels on display at power-up after drop sequence |
| Verdict | Does not meet acceptance criteria — display integrity failure on 1 sample |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number (表单编号) | BTK-R-Q-087A/1 |
| Report Number (编号) | 2025060501.0 |
| Page (页次) | 1.0 |
Frequently Asked Questions
What does the ETENWOLF P300 drop test result mean for product quality?
The P300 failed its 100 cm 6-face drop test because 1 out of 3 samples showed missing pixels on the display after the drop sequence. While charging and accuracy remained normal, the display defect is sufficient to constitute a Fail under the acceptance criteria. This result indicates a reliability concern with the display assembly under drop impact, and the product would require design or component improvements before passing this test.
What test height and conditions were used for the P300 drop test?
The P300 was tested at a drop height of 100 cm using a single-arm drop testing machine. Each sample was dropped once on each of 6 faces (6 drops total) in a laboratory environment maintained at 22 °C and 55% RH.
How many P300 samples were tested and what failed?
Three (3) P300 samples were tested. One sample (1 PCS) exhibited missing display pixels on power-up after completing all 6 drop faces. The other two samples showed no anomalies. Charging and measurement accuracy were normal across all three samples, and no housing cracks were observed.
What are the acceptance criteria for the P300 drop test?
The P300 must demonstrate normal appearance and full functional performance after the 6-face drop from 100 cm. Specifically, the housing must not crack, the display must operate correctly on power-up with no missing pixels, and charging and accuracy functions must remain normal. The failure of any one condition results in an overall Fail verdict.
Related Products
Explore other ETENWOLF inflation tools and view additional test documentation:
Additional test sheets from the same report file (P300球泵-跌落测试报告 2025.6.5.xls):
- Sheet1 — Secondary data sheet from the same drop test report (see full Excel source for supplementary data)