Document Overview
Key Findings The ETENWOLF P300 Smart Ball Pump successfully passed a 1-hour random vibration test conducted per ISTA-2A, with all three samples demonstrating normal button function, charging operation, and inflation accuracy after the full test duration. Test Standard: ISTA-2A Test Mode: Random vibration, X /…
- Document type
- Test Report
- Prepared by
- Jessica Lin
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF P300 Smart Ball Pump successfully passed a 1-hour random vibration test conducted per ISTA-2A, with all three samples demonstrating normal button function, charging operation, and inflation accuracy after the full test duration.
- Test Standard: ISTA-2A
- Test Mode: Random vibration, X / Y / Z axes
- Duration: 1 hour
- Vibration Frequency: 4 Hz
- Test Speed (CMP): 240 G
- Vibration Amplitude: 25.4 mm
- Samples Tested: 3 PCS
- Overall Verdict: PASS — no functional failures or appearance defects observed
Test Overview
| Field | Detail |
|---|---|
| Test Type | Transport Vibration Test (Vibration Test Report) |
| Test Standard | ISTA-2A |
| Report Number | 2025053001 |
| Page | 1 |
| Date | 2025-05-30 |
| Product Name | P300 Smart Ball Pump (P300-球泵) |
| Manufacturer | BTK |
| Surface Treatment | / |
| Sample Quantity | 3 PCS |
| Test Reason | New Product (■ New product) |
| Test Objective | To verify the resistance of the sample in transportation and use environment. |
| Laboratory Environment | Temperature: 22 °C; Humidity: 55% RH |
Test Equipment & Setup
| Parameter | Value |
|---|---|
| Instrument Name | Vibration Testing Machine |
| Test Mode | Random Mode |
| Test Duration | 1 H |
| Random Directions | X, Y, Z |
| Vibration Frequency | 4 Hz |
| Test Speed (CMP) | 240 G |
| Vibration Amplitude | 25.4 mm |
Test Procedure
- Pre-Test Inspection: Verify sample appearance and confirm normal power-on, button function, charging operation, and inflation accuracy on all 3 PCS prior to mounting.
- Sample Mounting: Place samples on the vibration testing machine platform in the designated orientation (vibration placement as documented in test pictures).
- Parameter Configuration: Set the machine to Random Mode, frequency 4 Hz, amplitude 25.4 mm, speed CMP 240 G.
- Vibration Execution: Run continuous random vibration across X, Y, and Z axes for a total duration of 1 hour.
- Post-Test Inspection: Power on each sample and verify: (a) normal startup and button function, (b) normal charging operation, (c) normal inflation accuracy. Record all observations and compare against acceptance criteria.
- Acceptance Criteria: After testing, the product must power on normally with no functional failures. Any failure in button response, charging, or inflation precision constitutes a non-conformance (Fail).
Test Data & Results
| Check Item | Pre-Test Status | Post-Test Status | Result |
|---|---|---|---|
| Appearance | No abnormality | No abnormality | Pass |
| Button Function | Normal | Normal | Pass |
| Charging Operation | Normal | Normal | Pass |
| Inflation Accuracy | Normal | Normal | Pass |
Test pictures documented: vibration placement setup and vibration control chart were recorded before testing. Post-test observation confirmed that all P300 samples demonstrated normal button function and performance with no anomalies after 1 hour of transport vibration.
Test Result Statement: After the P300 samples passed 1 hour of transport vibration, button functions and performance were normal with no anomalies detected.
Conclusion
| Field | Detail |
|---|---|
| Result | ■ Pass (合格) |
| Standard Applied | ISTA-2A |
| Test Conditions | Random mode; 4 Hz; 240 G CMP; 25.4 mm amplitude; X/Y/Z axes; 1 hour; 22 °C / 55% RH |
| Samples Tested | 3 PCS — P300 Smart Ball Pump |
| Verdict | PASS — All samples powered on normally after vibration; button function, charging, and inflation accuracy all confirmed normal. No functional failures or appearance defects observed. |
Document Information
| Role | Name |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number | BTK-R-Q-087A/1 |
Frequently Asked Questions
What does the ETENWOLF P300 transport vibration test verify?
The ETENWOLF P300 transport vibration test verifies that the smart ball pump can withstand the mechanical stresses of shipping and handling. The test uses ISTA-2A protocol, running 1 hour of random vibration across X, Y, and Z axes at 4 Hz frequency and 25.4 mm amplitude to simulate real-world transport conditions. After testing, samples must power on normally with no failures in button function, charging, or inflation accuracy.
What standard was used for the P300 vibration test, and did it pass?
The P300 vibration test followed the ISTA-2A standard. All 3 samples tested passed with a verdict of Pass (合格). Post-test inspection confirmed normal appearance, button operation, charging function, and inflation accuracy across every sample — no anomalies were recorded.
What are the key vibration test parameters for the P300?
The key parameters for the P300 transport vibration test are: test mode — random; duration — 1 hour; axes — X, Y, and Z; vibration frequency — 4 Hz; test speed (CMP) — 240 G; vibration amplitude — 25.4 mm. The test was conducted at 22 °C and 55% RH.
How many P300 samples were tested in the vibration report?
Three (3) PCS of the ETENWOLF P300 Smart Ball Pump were tested in report number 2025053001, dated 2025-05-30. All three samples passed the full 1-hour ISTA-2A random vibration test with no functional failures.