Document Overview
Key Findings The ETENWOLF P400 Electric Balloon Pump (B7 Balloon Inflator) successfully completed a 100 cm, 6-face single-arm drop test with no structural damage, no cracking, no deformation, and normal power-on function confirmed after all six drops. Product: B7 Electric Balloon Pump (Model P400) Drop…
- Document type
- Certification Report
- Prepared by
- Jessica Lin
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF P400 Electric Balloon Pump (B7 Balloon Inflator) successfully completed a 100 cm, 6-face single-arm drop test with no structural damage, no cracking, no deformation, and normal power-on function confirmed after all six drops.
- Product: B7 Electric Balloon Pump (Model P400)
- Drop Height: 100 cm
- Drop Faces: 6 (one drop per face, 6 total)
- Verdict: Reference Pass — no housing damage, no structural detachment, full functional operation confirmed
- Test Date: 2025-04-17
- Report No.: 2025041701
Test Overview
| Field | Detail |
|---|---|
| Test Type | Drop Test (Mechanical Reliability) |
| Report No. | 2025041701 |
| Page | 1 |
| Date | 2025-04-17 |
| Product Name | B7 Electric Balloon Pump (P400) |
| Manufacturer | BTK |
| Surface Treatment | Not specified |
| Sample Quantity | 3 PCS |
| Test Reason | New Product |
| Test Purpose | Evaluate the product’s resistance to drop impact and assess its reliability |
| Laboratory Temperature | 22 °C |
| Laboratory Humidity | 55% RH |
Test Equipment & Setup
| Parameter | Detail |
|---|---|
| Instrument Name | Single-Arm Drop Testing Machine |
| Drop Height | 100 cm |
| Number of Drops | 6 faces (6 drops total) |
| Sample Weight | Not recorded |
| Test Class | Not specified |
Test Procedure
- Pre-Test Inspection: Visually inspect all 3 sample units for any pre-existing damage, deformation, or cosmetic defects. Record baseline condition.
- Environment Verification: Confirm laboratory temperature is 22 °C and relative humidity is 55% RH before commencing.
- Sample Preparation: Mount the first sample on the single-arm drop testing machine at the specified drop height of 100 cm.
- Drop Execution — Face 1: Release the sample from 100 cm onto the first face. Inspect immediately after impact.
- Drop Execution — Face 2: Reposition sample to Face 2 orientation at 100 cm. Release and inspect.
- Drop Execution — Face 3: Reposition sample to Face 3 orientation at 100 cm. Release and inspect.
- Drop Execution — Face 4: Reposition sample to Face 4 orientation at 100 cm. Release and inspect.
- Drop Execution — Face 5: Reposition sample to Face 5 orientation at 100 cm. Release and inspect.
- Drop Execution — Face 6: Reposition sample to Face 6 orientation at 100 cm. Release and inspect.
- Post-Test Functional Check: Power on the unit and verify normal operation of all functions.
- Repeat: Repeat steps 3–10 for all remaining sample units.
- Documentation: Photograph units before and after all drops. Record all observations.
Acceptance Criteria: No damage, cracking, or deformation to structural components; power-on function operates normally after all 6 drops.
Test Data & Results
| Phase | Drop 1 | Drop 2 | Drop 3 | Drop 4 | Drop 5 | Drop 6 |
|---|---|---|---|---|---|---|
| Housing Condition After Drop | No damage | No damage | No damage | No damage | No damage | No damage |
| Power-On Function | Normal | Normal | Normal | Normal | Normal | Normal |
Pre-drop condition: All 3 samples inspected and confirmed free of pre-existing defects before testing commenced.
Post-drop observation: After the 100 cm single-arm drop across all 6 faces, the B7 samples showed no housing breakage, no structural detachment or disengagement, and power-on function was confirmed normal on all units.
Conclusion
| Item | Detail |
|---|---|
| Result | Reference Pass |
| Drop Standard | 100 cm, 6-face single-arm drop |
| Test Conditions | 22 °C, 55% RH |
| Samples Tested | 3 PCS |
| Housing Integrity | No damage, no cracking, no deformation |
| Structural Components | No detachment or disengagement observed |
| Functional Verdict | Power-on function normal after all drops |
| Overall Verdict | Reference Pass (■ Reference / 参考) |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number | BTK-R-Q-087A/1 |
Frequently Asked Questions
What drop height was used in the ETENWOLF P400 balloon pump drop test?
The P400 was tested at a drop height of 100 cm using a single-arm drop testing machine, covering all 6 faces of the unit (6 drops total).
Did the ETENWOLF P400 pass the drop test?
The P400 received a Reference Pass verdict. After all six 100 cm drops, the housing showed no damage, cracking, or deformation, and the power-on function operated normally on all 3 tested samples.
How many samples were tested in the P400 drop test?
Three (3) production samples were used for the drop test, conducted at 22 °C and 55% relative humidity.
What does a Reference Pass verdict mean in this drop test?
A Reference Pass (参考) indicates that the product met the acceptance criteria — no structural damage and normal function after testing — but the result is classified as a reference benchmark rather than a formal certification pass. This is common for new product evaluation tests.