ETENWOLF P300 Smart Ball Pump Drop Test Report (6-Face, Sheet1)

Document Overview

Key Findings The ETENWOLF P300 Smart Ball Pump completed a 6-face drop test sequence on all four samples. Two units (5# and 8#) exhibited minor front/rear shell misalignment on four faces while retaining full functional performance; the remaining two units (6# and 7#) showed no…

Document type
Test Report
Prepared by
Jessica Lin
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

The ETENWOLF P300 Smart Ball Pump completed a 6-face drop test sequence on all four samples. Two units (5# and 8#) exhibited minor front/rear shell misalignment on four faces while retaining full functional performance; the remaining two units (6# and 7#) showed no abnormality on any face.

  • Product: ETENWOLF P300 Smart Ball Pump
  • Test Type: Drop Test (Mechanical Reliability)
  • Drop Faces: 6 (Back, Right Side, Front, Left Side, Bottom, Top)
  • Samples Tested: 4 units (5#, 6#, 7#, 8#)
  • Test Date: 2025-06-05 (Excel serial 45454)
  • Overall Verdict: All units functional after all drops; cosmetic shell misalignment noted on 2 of 4 units across 4 faces

Test Overview

Field Detail
Test Type Drop Test — Mechanical Reliability
Report File P300球泵-跌落测试报告 2025.6.5.xls
Sheet Sheet1 (Sheet Index 2 of 2)
Test Date 2025-06-05
Product ETENWOLF P300 Smart Ball Pump
Product Line Sports & Recreation
Category Ball Pump (球泵类)
Model P300
Samples 4 units: 5#, 6#, 7#, 8#
Total Sheets in Source File 2 (跌落试验报告, Sheet1)

Test Equipment & Setup

Parameter Value
Test Method 6-face free-fall drop
Number of Drop Faces 6
Face 1 (Drop 1) Back face down (背面朝下)
Face 2 (Drop 2) Right side face down (右侧面朝下)
Face 3 (Drop 3) Front face down (正面朝下)
Face 4 (Drop 4) Left side face down (左侧面朝下)
Face 5 (Drop 5) Bottom face down (底面朝下)
Face 6 (Drop 6) Top face down (上面朝下)
Sample IDs 5#, 6#, 7#, 8#
Evaluation Criteria Visual inspection of housing integrity + functional verification after each drop

Test Procedure

  1. Pre-test: Visually inspect each sample and confirm normal operation before testing begins.
  2. Setup: Position the unit at the specified drop height with the designated face oriented downward.
  3. Drop 1 — Back face down (背面朝下): Release unit in free fall onto hard surface; inspect and record result.
  4. Drop 2 — Right side face down (右侧面朝下): Reorient unit; release and record result.
  5. Drop 3 — Front face down (正面朝下): Reorient unit; release and record result.
  6. Drop 4 — Left side face down (左侧面朝下): Reorient unit; release and record result.
  7. Drop 5 — Bottom face down (底面朝下): Reorient unit; release and record result.
  8. Drop 6 — Top face down (上面朝下): Reorient unit; release and record result.
  9. Post-test: After all 6 drops, perform full functional test on each unit. Record any structural damage, housing misalignment, or performance degradation.
  10. Acceptance Criteria: Unit passes if core inflation function remains intact after all 6 drops. Cosmetic shell misalignment without functional impact is noted but does not constitute a functional failure.

Test Data & Results

Test Date Sample No. Drop 1 — Back Face Down Drop 2 — Right Side Face Down Drop 3 — Front Face Down Drop 4 — Left Side Face Down Drop 5 — Bottom Face Down Drop 6 — Top Face Down
2025-06-05 5# No abnormality No abnormality Front/rear shell misalignment; function normal Front/rear shell misalignment; function normal Front/rear shell misalignment; function normal Front/rear shell misalignment; function normal
6# No abnormality No abnormality No abnormality No abnormality No abnormality No abnormality
7# No abnormality No abnormality No abnormality No abnormality No abnormality No abnormality
8# No abnormality No abnormality Front/rear shell misalignment; function normal Front/rear shell misalignment; function normal Front/rear shell misalignment; function normal Front/rear shell misalignment; function normal

Observations: Samples 6# and 7# passed all 6 drop faces with zero abnormalities. Samples 5# and 8# exhibited front/rear housing shell misalignment beginning at Drop 3 (front face down) and persisting through Drops 4, 5, and 6. In both cases the inflation function remained fully operational. No cracks, broken components, or complete housing separation were recorded on any unit.

Conclusion

Item Detail
Test 6-Face Drop Test
Samples 4 units (5#, 6#, 7#, 8#)
Test Date 2025-06-05
Functional Result All 4 units retained full inflation function after all 6 drops
Cosmetic Result 2 of 4 units (5#, 8#) showed front/rear shell misalignment on Drops 3–6; 2 of 4 units (6#, 7#) showed no abnormality
Verdict PASS — All units functionally operational post-test

Document Information

Role Name
Author / Publisher Jessica Lin
Source File P300球泵-跌落测试报告 2025.6.5.xls
Term ID 127
Author ID 5
Date Published 2026-07-12

Frequently Asked Questions

Did the ETENWOLF P300 pass the 6-face drop test?

Yes. All four P300 samples (5#, 6#, 7#, 8#) retained full inflation functionality after completing all six drop orientations. Two units showed minor front/rear shell misalignment but no functional degradation.

What does ‘front/rear shell misalignment’ mean for the P300 drop test?

Shell misalignment means the front and rear housing panels shifted slightly out of alignment upon impact. In both affected units (5# and 8#), this was a cosmetic outcome only — the pump mechanism, controls, and output performance were unaffected.

Which drop orientations caused issues for the P300?

For samples 5# and 8#, misalignment first appeared on Drop 3 (front face down) and was also present on Drops 4 (left side), 5 (bottom), and 6 (top). Drops 1 (back) and 2 (right side) produced no abnormality on any unit.

How many P300 units were tested in this drop test?

Four units were tested, numbered 5#, 6#, 7#, and 8#. The test was conducted on 2025-06-05 using a 6-face free-fall drop sequence covering all principal orientations of the product.