Document Overview
Document Overview This page presents the official RoHS test report issued by Waltek Testing Group (Shenzhen) Co., Ltd. for the ETENWOLF P600 Electric Balloon Pump. The report covers testing performed in accordance with the EU RoHS Directive to verify that the product does not exceed…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- European Union: CE / RoHS / REACH / WEEE
Document Overview
This page presents the official RoHS test report issued by Waltek Testing Group (Shenzhen) Co., Ltd. for the ETENWOLF P600 Electric Balloon Pump. The report covers testing performed in accordance with the EU RoHS Directive to verify that the product does not exceed the maximum concentration limits for ten restricted hazardous substances.
| Field | Detail |
|---|---|
| Document Type | Test Report – RoHS Compliance |
| Report Number | WTH25X11294797C |
| Issuing Body | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Date of Issue | 2026-01-19 |
| Date of Sample Receipt | 2025-11-11 & 2026-01-12 |
| Testing Period | 2025-11-11 ~ 2025-11-24 & 2026-01-12 ~ 2026-01-14 |
| Directive Scope | EU RoHS Directive 2011/65/EU and amendment (EU) No. 2015/863 — 10 restricted substances |
| Overall Conclusion | PASS |
Product Information
The tested product is the ETENWOLF P600 Electric Balloon Pump, an electric inflation tool designed for rapid balloon inflation. Full product details as recorded in the test report are listed below.
| Field | Detail |
|---|---|
| Sample Name | Electric Balloon Pump |
| Model Number | P600 |
| Reference Model | NA |
| Brand | ETENWOLF (filed as NA in report; product is the ETENWOLF P600) |
| Applicant | Guangdong Bestek Technology Co., LTD |
| Applicant Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
| Manufacturer | Guangdong Bestek Technology Co., LTD |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
Key Details
Waltek tested multiple component parts of the ETENWOLF P600 for the presence of lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (Cr⁶⁺), polybrominated biphenyls (PBBs), polybrominated diphenyl ethers (PBDEs), and four restricted phthalates. All tested parts returned a Below Limit (BL) or compliant result under both XRF screening and chemical confirmation methods.
| No. | Part Description | XRF Screen | Pb (mg/kg) | Cd (mg/kg) | Hg (mg/kg) | Cr (mg/kg) | Br (mg/kg) |
|---|---|---|---|---|---|---|---|
| 1 | Pink plastic shell | BL | BL | BL | BL | BL | NA |
| 2 | White plastic shell | BL | BL | BL | BL | BL | NA |
| 3 | Purple plastic component | BL | BL | BL | BL | BL | NA |
Note: The extracted source text was truncated at part 3. The full report (WTH25X11294797C, 26 pages) contains test data for all identified component parts. BL = Below Detection Limit; NA = Not Applicable (substance not relevant to that material category).
The ten restricted substances evaluated under RoHS Directive 2011/65/EU and its amendment (EU) 2015/863 are: Lead (Pb), Mercury (Hg), Cadmium (Cd), Hexavalent Chromium (Cr⁶⁺), Polybrominated Biphenyls (PBBs), Polybrominated Diphenyl Ethers (PBDEs), Di(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP), and Diisobutyl phthalate (DIBP).
Standards & Compliance
All testing was conducted using internationally recognised IEC test methods applicable to the determination of restricted substances in electrical and electronic equipment. The following standards were applied:
| Standard | Scope / Analytes | Technique |
|---|---|---|
| IEC 62321-3-1:2013 | Screening — Pb, Hg, Cd, total Cr, total Br | X-ray Fluorescence Spectrometry (XRF) |
| IEC 62321-4:2013+AMD1:2017 CSV | Mercury (Hg) | ICP-OES |
| IEC 62321-5:2013 | Lead (Pb) and Cadmium (Cd) | ICP-OES |
| IEC 62321-7-2:2017 and/or IEC 62321-7-1:2015 | Hexavalent Chromium (Cr⁶⁺) | UV-Vis Spectrophotometry |
| IEC 62321-6:2015 | PBBs and PBDEs | GC-MS |
| IEC 62321-8:2017 | Phthalates (DEHP, BBP, DBP, DIBP) | GC-MS |
The governing regulatory framework is EU RoHS Directive 2011/65/EU as amended by (EU) No. 2015/863, which extended the list of restricted phthalates from six to ten substances.
Validity & Certification Body
This test report was issued on 2026-01-19 by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory. The report is signed by Hugo Chen on behalf of Waltek Testing Group.
| Field | Detail |
|---|---|
| Report Number | WTH25X11294797C |
| Date of Issue | 2026-01-19 |
| Signed By | Hugo Chen, Waltek Testing Group (Shenzhen) Co., Ltd. |
| Laboratory Name | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Laboratory Address | 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China |
| Website | http://www.waltek.com.cn |
| Tel | +86-755-33663308 |
| Fax | +86-755-33663309 |
| [email protected] | |
| Report Validity | Applicable to the tested samples and manufacturing configuration at the time of testing. Any change in materials or components may require re-testing. |
Frequently Asked Questions
- Does the ETENWOLF P600 Electric Balloon Pump comply with the EU RoHS Directive?
-
Yes. The ETENWOLF P600 Electric Balloon Pump has been independently tested by Waltek Testing Group (Shenzhen) Co., Ltd. and achieved a PASS result under EU RoHS Directive 2011/65/EU and its amendment (EU) No. 2015/863. The result is documented in test report number WTH25X11294797C, issued on 2026-01-19.
- Which hazardous substances were tested in the P600?
-
The ten restricted substances tested are: Lead (Pb), Mercury (Hg), Cadmium (Cd), Hexavalent Chromium (Cr⁶⁺), Polybrominated Biphenyls (PBBs), Polybrominated Diphenyl Ethers (PBDEs), Di(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP), and Diisobutyl phthalate (DIBP). All tested component parts of the P600 returned results below the maximum permitted concentration values.
- What test methods were used to verify the P600’s RoHS compliance?
-
Waltek used a combination of X-ray Fluorescence (XRF) screening per IEC 62321-3-1:2013 and confirmatory chemical analysis methods including ICP-OES (for Pb, Cd, Hg), UV-Vis (for Cr⁶⁺), and GC-MS (for PBBs, PBDEs, and phthalates) per the relevant IEC 62321 series standards.
- Who conducted the RoHS testing for the ETENWOLF P600?
-
Testing was conducted by Waltek Testing Group (Shenzhen) Co., Ltd., an independent accredited third-party laboratory based in Shenzhen, Guangdong, China. The report was prepared and signed by Hugo Chen on 2026-01-19 under report number WTH25X11294797C.
Related Documents
The following certification and compliance document types are typically associated with an electric balloon pump such as the ETENWOLF P600 and are recommended for a complete regulatory documentation package:
- CE Declaration of Conformity — Required for placing the P600 on the EU market; covers the Low Voltage Directive (LVD) 2014/35/EU and EMC Directive 2014/30/EU.
- FCC Declaration of Conformity — Required for the US market under FCC Part 15 rules for unintentional radiators.
- IEC 62321 Full Series Test Reports — Detailed underlying chemical test data supporting the RoHS compliance conclusion in report WTH25X11294797C.
- REACH SVHC Screening Report — Assesses substances of very high concern under EU REACH Regulation (EC) No. 1907/2006, complementing the RoHS report.
- UN 38.3 Test Report — If the P600 ships with a lithium battery pack, a UN 38.3 transport test report is required for air and sea freight.
- KC Certification — Required for the South Korean market under the KC Mark scheme administered by NRRA.