FCC CFR 47 Part 15 Subpart B EMC Test Report – P300 / P300 PLUS Inflator Pump

Document Overview

Document Overview This article covers the official FCC electromagnetic compatibility (EMC) test report issued for the P300 / P300 PLUS inflator pump. The document is classified as a Test Report under reference number WTH25H09255940E (internal reference: WTH25H09255940), prepared in accordance with FCC CFR 47 Part…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
Sports & Recreation

Document Overview

This article covers the official FCC electromagnetic compatibility (EMC) test report issued for the P300 / P300 PLUS inflator pump. The document is classified as a Test Report under reference number WTH25H09255940E (internal reference: WTH25H09255940), prepared in accordance with FCC CFR 47 Part 15 Subpart B — the United States federal standard governing unintentional radiators and their limits for both conducted and radiated emissions.

The report was issued on 2025-09-29 by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party electromagnetic compatibility testing laboratory located in Shenzhen, Guangdong, China. The test report form number is TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01, and the overall test result is Pass. The scope of the assessment covers conducted emissions and radiated emissions generated by the equipment under test (EUT) during normal operating conditions.

Product Information

The equipment under test is the P300 / P300 PLUS inflator pump, a portable electric inflation tool distributed under the ETENWOLF brand. The product is manufactured and supplied by Guangdong Bestek Technology Co., Ltd., whose registered address is No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China. The same entity acts as both applicant and manufacturer on the certification record.

Field Details
EUT Name Inflator Pump
Model Number P300 / P300 PLUS
Trade Mark N/A
Applicant Guangdong Bestek Technology Co., Ltd.
Manufacturer Guangdong Bestek Technology Co., Ltd.
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Product Category Unintentional Radiator – Portable Inflation Tool

The P300 / P300 PLUS is designed for inflating vehicle tires, sports equipment, and other inflatables. Its internal motor and power circuitry constitute the primary sources of electromagnetic emissions evaluated during this test campaign.

Key Details

The test campaign ran from 2025-09-25 to 2025-09-28, with the sample received on 2025-09-23 and the final report issued on 2025-09-29. Two main emission categories were assessed: conducted emissions and radiated emissions. The following table summarises the key test and report parameters.

Parameter Value
Reference Number WTH25H09255940E
Internal Reference Number WTH25H09255940
Test Report Form No. TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01
Test Specification FCC CFR 47 Part 15 Subpart B
Date of Sample Receipt 2025-09-23
Date of Test 2025-09-25 to 2025-09-28
Date of Issue 2025-09-29
Overall Test Result Pass
Prepared By Snow Zeng
Approved By Tony Wu

The test report is structured across 26 pages and includes the following major sections: General Information, System Test Configuration, Conducted Emission measurements and data, Radiated Emission measurements and data, EUT photographs (Appendix A), and Test Setup photographs (Appendix B). The conducted emission section documents measurement uncertainty, applicable limits, EUT setup, instrument setup, test procedure, equipment list, and tabulated test data. The radiated emission section similarly documents uncertainty budgets, limits, antenna and receiver configurations, corrected amplitude and margin calculations, and full test data tables.

Standards & Compliance

The P300 / P300 PLUS inflator pump was evaluated against the following regulatory standard and associated technical requirements.

Standard Scope Result
FCC CFR 47 Part 15 Subpart B Unintentional radiators – conducted and radiated emission limits for the United States market Pass

Under FCC CFR 47 Part 15 Subpart B, unintentional radiators such as the P300 / P300 PLUS must demonstrate that electromagnetic emissions on the AC mains (conducted emissions) and through the air (radiated emissions) remain below the prescribed Class B limits. Class B limits apply to devices intended for use in residential environments, providing a more stringent level of protection against interference to radio communications than Class A limits.

The conducted emission tests measure noise current or voltage injected back onto the power supply lines in the frequency range typically from 150 kHz to 30 MHz. The radiated emission tests measure the electric field strength radiated by the EUT, typically from 30 MHz to 1 GHz (and above where required), at a defined measurement distance. Both sets of measurements incorporate a documented measurement uncertainty budget, and the decision rule applied for pass/fail determination is recorded within the report body under Section 2.6.

Validity & Certification Body

The test report bearing reference number WTH25H09255940E was issued by:

Field Details
Laboratory Name Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Address Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
Telephone 0755-84616666
Service Hotline 400-0066-989
Email [email protected]
Report Reference HCT/RF-23-21
Date of Issue 2025-09-29

FCC test reports issued by accredited laboratories serve as the technical basis for a Declaration of Conformity (DoC) or FCC filing. The validity of this report is contingent on the product remaining unchanged from the tested sample configuration. Any design modification to the circuitry, enclosure, power supply, or firmware that could affect electromagnetic emission characteristics would require re-evaluation. The report covers the specific model and configuration described in Section 1.1 of the original document and should be read in conjunction with the EUT photographs in Appendix A and the test setup photographs in Appendix B.

Frequently Asked Questions

What does the FCC CFR 47 Part 15 Subpart B test verify for the P300 / P300 PLUS inflator pump?
The test verifies that the P300 / P300 PLUS inflator pump does not generate electromagnetic interference above the limits set by the US Federal Communications Commission for unintentional radiators. It covers both conducted emissions — noise fed back into the power supply lines — and radiated emissions — electromagnetic fields emitted through the air. A passing result means the product meets FCC Class B requirements and is suitable for sale and use in the United States.
What is the significance of reference number WTH25H09255940E?
WTH25H09255940E is the unique test report reference number assigned by Waltek Testing Group HCT (Shenzhen) Co., Ltd. to this specific EMC assessment. It can be used to trace the full 26-page report, including all raw measurement data, test equipment calibration records, uncertainty budgets, and photographic documentation of the EUT and test setup. The companion internal reference is WTH25H09255940.
Does a passing FCC Part 15 Subpart B result mean the P300 / P300 PLUS is FCC authorised for sale in the US?
A passing test report is a required technical foundation for FCC market authorisation, but the authorisation process also involves filing a Supplier’s Declaration of Conformity (SDoC) or obtaining a Certification (depending on device category), labelling the product with the FCC ID or compliance statement, and maintaining the technical documentation on file. This test report supports that process for the P300 / P300 PLUS.
Who prepared and approved the FCC EMC test report for the P300 / P300 PLUS?
The report was prepared by Snow Zeng and approved by Tony Wu at Waltek Testing Group HCT (Shenzhen) Co., Ltd. The laboratory’s internal form reference is HCT/RF-23-21 and the test report form number is TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01.

Related Documents

The following certification and compliance documents are typically required alongside an FCC EMC test report for a portable inflator pump such as the P300 / P300 PLUS when targeting international markets:

  • CE EMC Declaration (EN 55014-1 / EN 55014-2) — Required for sale in the European Economic Area, covering conducted and radiated emissions as well as immunity for household motor-operated equipment.
  • CE LVD / Safety Report (EN 62368-1 or EN 60335 series) — Low Voltage Directive compliance report addressing electrical safety for the European market.
  • RoHS Compliance Report — Confirms restriction of hazardous substances in electrical and electronic equipment per EU Directive 2011/65/EU.
  • REACH SVHC Declaration — Documents that substances of very high concern remain below threshold levels per REACH Regulation (EC) No 1907/2006.
  • KC Certification (KCs / KCc) — Korean Certification mark required for electrical products distributed in South Korea.
  • UN 38.3 Battery Test Report — If the P300 / P300 PLUS variant includes a built-in lithium battery, a UN 38.3 transport safety test report is required for international shipping.
  • PSE Certification (Japan) — Required for electrical products entering the Japanese market under the Electrical Appliances and Materials Safety Act.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26