Document Overview
Document Overview This page presents the RoHS compliance test report for the ETENWOLF P300 and P300PLUS inflator pump, issued by Waltek Testing Group (Shenzhen) Co., Ltd. The report covers the determination of 10 restricted hazardous substances in accordance with the EU RoHS Directive and its…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- Sports & Recreation
Document Overview
This page presents the RoHS compliance test report for the ETENWOLF P300 and P300PLUS inflator pump, issued by Waltek Testing Group (Shenzhen) Co., Ltd. The report covers the determination of 10 restricted hazardous substances in accordance with the EU RoHS Directive and its amendment.
| Field | Details |
|---|---|
| Report Number | WTH25X09255941C |
| Document Type | RoHS Compliance Test Report |
| Issuing Laboratory | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Date of Issue | 2025-10-20 |
| Applicable Directive | EU RoHS Directive 2011/65/EU and amendment (EU) 2015/863 |
| Scope | Determination of 10 restricted substances content in submitted inflator pump samples |
| Test Conclusion | PASS — results comply with EU RoHS Directive 2011/65/EU and amendment (EU) 2015/863 |
Product Information
The tested product is the ETENWOLF P300 / P300PLUS inflator pump, a portable tire and gear inflation tool designed for automotive and outdoor use. The samples were submitted by the applicant and manufacturer Guangdong Bestek Technology Co., LTD.
| Field | Details |
|---|---|
| Sample Name | Inflator Pump |
| Model Number | P300, P300PLUS |
| Reference Model | NA |
| Brand | ETENWOLF |
| Applicant | Guangdong Bestek Technology Co., LTD |
| Applicant Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
| Manufacturer | Guangdong Bestek Technology Co., LTD |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
| Date of Receipt | 2025-09-23 and 2025-10-11 |
| Testing Period | 2025-09-23 to 2025-09-29 and 2025-10-11 to 2025-10-14 |
Key Details
A total of 75 individual parts and materials were disassembled from the P300 / P300PLUS samples and tested for the presence of lead (Pb), cadmium (Cd), mercury (Hg), total chromium (Cr), bromine (Br), hexavalent chromium (Cr6+), polybrominated biphenyls (PBBs), polybrominated diphenyl ethers (PBDEs), and phthalates. All parts returned below-limit (BL) or not-detected (ND) results. Parts with an initial XRF indication (IN) for chromium were subjected to further chemical testing for Cr6+, which returned Negative or ND in every case.
Selected representative results from the 75-part test matrix are shown below:
| No. | Part Description | XRF Result | Pb | Cd | Hg | Cr | Br / Chemical Test |
|---|---|---|---|---|---|---|---|
| 1 | Black w/transparent plastic | BL | BL | BL | BL | BL | NA |
| 2 | Orange plastic shell | BL | BL | BL | BL | BL | NA |
| 8 | Silvery metal screw | — | BL | BL | BL | IN | Cr6+: Negative |
| 15 | Silvery metal axle | — | BL | BL | BL | IN | Cr6+: Negative |
| 41 | Silvery metal axle | — | BL | BL | BL | IN | Cr6+: Negative |
| 42 | Silvery metal shell | — | BL | BL | BL | IN | Cr6+: Negative |
| 46 | Silvery metal sheet (switch) | — | BL | BL | BL | IN | Cr6+: Negative |
| 54 | Black resistance SMD | — | BL | BL | BL | IN | Cr6+: ND |
| 59 | Black cladding PCB board (whole) | — | BL | BL | BL | BL | PBBs: ND; PBDEs: ND |
| 60 | Solder | BL | BL | BL | BL | NA | NA |
| 75 | Blue green plastic shell | BL | BL | BL | BL | BL | NA |
Legend: BL = Below Limit of Detection; IN = Initial (XRF indication requiring further chemical test); NA = Not Applicable; ND = Not Detected; Negative = Cr6+ confirmed absent by UV-Vis.
Standards & Compliance
The testing was performed in accordance with the EU RoHS Directive 2011/65/EU and its amendment (EU) 2015/863, which restricts the use of 10 hazardous substances in electrical and electronic equipment. The following IEC standard test methods were applied:
| Standard | Substance(s) Covered | Analytical Method |
|---|---|---|
| IEC 62321-3-1:2013 | Lead, Mercury, Cadmium, total Chromium, total Bromine — screening | X-Ray Fluorescence Spectrometry (XRF) |
| IEC 62321-4:2013+AMD1:2017 CSV | Mercury (Hg) | ICP-OES |
| IEC 62321-5:2013 | Lead (Pb) and Cadmium (Cd) | ICP-OES |
| IEC 62321-7-2:2017 and/or IEC 62321-7-1:2015 | Hexavalent Chromium (Cr6+) | UV-Vis Spectrophotometry |
| IEC 62321-6:2015 | Polybrominated Biphenyls (PBBs) and Polybrominated Diphenyl Ethers (PBDEs) | GC-MS |
| IEC 62321-8:2017 | Phthalates (DEHP, BBP, DBP, DIBP) | GC-MS |
All 75 tested components of the P300 / P300PLUS inflator pump met the concentration limits prescribed by the directive, confirming full RoHS compliance for European market distribution.
Validity & Certification Body
The test report was prepared and issued by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory. The report was signed on behalf of the laboratory by Hugo Chen.
| Field | Details |
|---|---|
| Report Number | WTH25X09255941C |
| Date of Issue | 2025-10-20 |
| Testing Laboratory | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Laboratory Address | 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China |
| Laboratory Website | http://www.waltek.com.cn |
| Tel | +86-755-33663308 |
| Fax | +86-755-33663309 |
| [email protected] | |
| Signed By | Hugo Chen, Waltek Testing Group (Shenzhen) Co., Ltd. |
| Report Validity | This report is valid for the tested samples as submitted. Results apply solely to the samples tested and do not constitute ongoing product certification unless renewed. |
Frequently Asked Questions
- What does the RoHS test result mean for the P300 and P300PLUS inflator pump?
-
The PASS result means that all 75 disassembled components of the P300 and P300PLUS inflator pump were found to contain restricted hazardous substances — including lead, mercury, cadmium, hexavalent chromium, PBBs, PBDEs, and four phthalates — at concentrations below the maximum limits set by EU RoHS Directive 2011/65/EU and its amendment (EU) 2015/863. The products are safe for sale and distribution within the European Union.
- Which hazardous substances are covered by this RoHS test?
-
The test covers the 10 substances restricted by the current EU RoHS Directive: lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (Cr6+), polybrominated biphenyls (PBBs), polybrominated diphenyl ethers (PBDEs), and four phthalates — DEHP, BBP, DBP, and DIBP. Each was evaluated using the corresponding IEC 62321 series test methods.
- Why do some metal parts show an XRF indication (IN) for chromium, yet still pass?
-
An XRF indication (IN) for chromium means the screening detected the presence of chromium in that part, but does not distinguish between non-toxic trivalent chromium (Cr3+) and the restricted hexavalent form (Cr6+). Those parts were then subjected to confirmatory chemical testing by UV-Vis spectrophotometry per IEC 62321-7-2:2017 and/or IEC 62321-7-1:2015. In every case the result was Negative or ND, confirming no hexavalent chromium was present above the limit.
- Is this report sufficient to demonstrate RoHS compliance for EU customs and distributors?
-
This Waltek test report (WTH25X09255941C) provides the technical evidence required for a RoHS Declaration of Conformity. Manufacturers and importers are required to hold such technical documentation and issue a DoC before placing the product on the EU market. Distributors and customs authorities typically accept accredited third-party test reports of this nature as supporting evidence of compliance.
Related Documents
For a complete compliance dossier for the P300 / P300PLUS inflator pump, the following related certification and test documents are recommended:
- CE Declaration of Conformity — Formal EU declaration referencing applicable directives including RoHS 2011/65/EU and LVD/EMC where applicable.
- REACH Compliance Statement — Confirming the product does not contain Substances of Very High Concern (SVHCs) above 0.1% by weight, per REACH Regulation (EC) No 1907/2006.
- UN 38.3 Battery Transport Test Report — Required for the built-in lithium battery to comply with UN 38.3 transportation safety regulations.
- FCC / CE EMC Test Report — Electromagnetic compatibility testing for markets in the United States (FCC) and the European Union.
- KC Certification — Safety and EMC certification required for the South Korean market, issued under the KC Mark scheme.
- ISO 9001 Quality Management Certificate — Manufacturer quality management system certification from ISO, supporting overall product quality assurance.
Document Pages