Document Overview
Document Overview This page presents the CE Low Voltage Directive (LVD) test report issued for the ETENWOLF P300 / P300 PLUS inflator pump. The report was prepared by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory, and covers safety and electromagnetic field…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- Sports & Recreation
Document Overview
This page presents the CE Low Voltage Directive (LVD) test report issued for the ETENWOLF P300 / P300 PLUS inflator pump. The report was prepared by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory, and covers safety and electromagnetic field exposure evaluations required for CE marking under the EU Low Voltage Directive.
- Reference No.: WTH25X09255938J
- Test Report Form No.: WTX_EN IEC 60335_1_2023B
- Date of Receipt of Sample: 2025-09-25
- Date of Test: 2025-09-25 to 2025-09-28
- Date of Issue: 2025-09-29
- Overall Test Result: PASS
- Issuing Laboratory: Waltek Testing Group (Shenzhen) Co., Ltd., 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China
- Tested By: John Zhong / Project Engineer
- Approved By: Harvid Wei / Manager
The test results documented herein apply exclusively to the sample(s) submitted for testing. The report may not be reproduced except in full and with prior written permission from Waltek Testing Group.
Product Information
The product evaluated is a portable electric inflator pump designed for household and indoor use. Full product details extracted from the test report are listed below.
| Field | Detail |
|---|---|
| Product Name | Inflator Pump |
| Brand / Trademark | ETENWOLF |
| Model No. | P300 / P300 PLUS |
| Rated Input Voltage | 5 V DC |
| Rated Input Current | 2.0 A |
| Supply Connection | DC Connector |
| Equipment Class | Class III (Safety Extra-Low Voltage) |
| Installation Type | Portable appliance, indoor use only |
| Ingress Protection | IPX0 (no water protection rating required) |
| Country of Manufacture | China |
| Applicant / Manufacturer | Guangdong Bestek Technology Co., Ltd., No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
As a Class III appliance, the P300 operates at safety extra-low voltage and is powered via a DC connector, eliminating risks associated with mains voltage exposure to the user.
Key Details
The test report covers a full clause-by-clause evaluation against the applicable standards. The table below summarises the key test clauses, requirements, and verdicts recorded during testing.
| Clause (EN IEC 60335-1) | Requirement / Test Area | Verdict |
|---|---|---|
| Clause 5 | General Conditions for Tests (nature of supply, test sequence) | Pass |
| Clause 6.1 | Classification – Protection against electric shock (Class III) | Pass |
| Clause 6.2 | Protection against harmful ingress of water (IPX0) | N/A |
| Clause 7.1 | Marking – Rated voltage, current, manufacturer identity, model reference | Pass |
| Clause 7.1 | Marking – Class III symbol (battery-operated / rechargeable battery appliance) | Pass |
| Clause 7.1 | Symbol IEC 60417-5172 (Class II) – Not applicable to Class III | N/A |
| Clause 7.1 | Detachable power supply part markings | Pass |
| EN 62233:2008 | Measurement of electromagnetic fields (EMF) for human exposure | Pass |
Marking label requirements specify that when the product is placed on the EU market, both the importer name/address and manufacturer name/address must be affixed to the product. The CE mark minimum height is 5 mm and the WEEE symbol minimum height is 7 mm.
Label reference information confirmed on the sample:
- Product: Inflator Pump
- Model: P300
- Input: 5 V / 2.0 A
- Manufacturer: Guangdong Bestek Technology Co., Ltd., Heyuan City, Guangdong, P.R. China
- Made in China
Standards & Compliance
The P300 / P300 PLUS inflator pump was evaluated against the following standards as part of its CE LVD certification process.
| Standard | Title | Scope |
|---|---|---|
| EN IEC 60335-1:2023+A11:2023 | Household and Similar Electrical Appliances – Safety – Part 1: General Requirements | Primary safety standard covering construction, protection, marking, and testing requirements for household electrical appliances |
| EN 62233:2008 | Measurement Methods for Electromagnetic Fields of Household Appliances and Similar Apparatus with Regard to Human Exposure | Defines measurement methods for EMF emissions to assess human exposure compliance |
Both standards are harmonised under the EU Low Voltage Directive (LVD) 2014/35/EU and support CE marking obligations for electrical equipment placed on the European market. The product fully complies with all applicable clauses of these standards.
Key compliance points confirmed:
- Class III equipment construction verified — operates at safety extra-low voltage
- All required marking and labelling obligations met per Clause 7
- EMF human exposure levels within permissible limits per EN 62233:2008
- General safety construction requirements satisfied per EN IEC 60335-1:2023
Validity & Certification Body
The test report was issued on 2025-09-29 by Waltek Testing Group (Shenzhen) Co., Ltd. Details of the certification body and report validity are provided below.
| Field | Detail |
|---|---|
| Report Reference No. | WTH25X09255938J |
| Date of Issue | 2025-09-29 |
| Testing Period | 2025-09-25 to 2025-09-28 |
| Testing Laboratory | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Laboratory Address | 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China |
| Laboratory Website | http://www.waltek.com.cn |
| Tel | +86-755-33663308 |
| Fax | +86-755-33663309 |
| [email protected] | |
| Sub-contracting | No sub-contracting to other laboratories |
| Report Validity | Valid as issued; report is invalid without the official stamp of the test institute and authorised signatures |
Waltek Testing Group is an internationally recognised testing and certification body providing compliance services across consumer electronics, household appliances, and industrial products. The report bears authorised signatures from the Project Engineer and the Laboratory Manager, confirming its authenticity.
Frequently Asked Questions
- What does the CE LVD certification mean for the ETENWOLF P300 inflator pump?
-
CE LVD (Low Voltage Directive) certification confirms that the P300 inflator pump has been independently tested and verified to meet the electrical safety requirements set by the European Union under Directive 2014/35/EU. The pump passed all applicable clauses of EN IEC 60335-1:2023+A11:2023, making it legally compliant for sale within the EU and EEA markets.
- What is the report reference number for the P300 CE LVD test, and when was it issued?
-
The test report reference number is WTH25X09255938J. Testing was conducted from 2025-09-25 to 2025-09-28 at Waltek Testing Group (Shenzhen) Co., Ltd., and the report was officially issued on 2025-09-29.
- Why is the P300 classified as a Class III appliance?
-
Class III classification means the P300 operates at Safety Extra-Low Voltage (SELV), supplied via a DC connector rated at 5 V / 2.0 A. This classification provides an inherent level of protection against electric shock without requiring additional insulation layers, as the operating voltage itself is too low to pose a direct shock hazard under normal conditions.
- Does the P300 inflator pump comply with EMF human exposure limits?
-
Yes. The P300 was tested according to EN 62233:2008, the standard governing measurement of electromagnetic fields from household appliances with regard to human exposure. The pump passed this evaluation, confirming that EMF emissions during normal operation are within the limits considered safe for users.
Related Documents
The CE LVD test report is one component of the broader compliance documentation package for the ETENWOLF P300 / P300 PLUS inflator pump. The following related certification types are typically required or recommended for this product category:
- CE EMC Declaration (Electromagnetic Compatibility) – Tests conducted under EN 55014-1 and EN 55014-2 to verify emission and immunity compliance for the EU market.
- CE RED Certification (Radio Equipment Directive) – Applicable if the product incorporates Bluetooth, Wi-Fi, or other wireless communication modules.
- UN 38.3 Battery Transport Certification – Required for products containing lithium-ion or lithium-polymer battery cells to comply with international transport safety regulations.
- RoHS Compliance Report – Confirms the product is free from restricted hazardous substances (lead, mercury, cadmium, etc.) as required by EU RoHS Directive 2011/65/EU.
- REACH SVHC Declaration – Substance of Very High Concern declaration confirming compliance with REACH Regulation (EC) No 1907/2006.
- FCC Declaration of Conformity – Required for market entry into the United States, covering radio frequency emissions.
- KC Certification – Required for the South Korean market under the KC safety and EMC framework.