ETENWOLF FL2 Flashlight IPX4 Waterproof Test Report

Document Overview

Key Findings The ETENWOLF FL2 flashlight passed IPX4 waterproof validation — all 3 samples showed zero internal moisture ingress after 3 minutes of multi-angle low-pressure water spray. Product: FL2 Flashlight Report No.: 2025110301 Test Date: 2025-11-03 Standard: Internal Control Standard (IPX4 criteria) Samples: 3 PCS…

Document type
Test Report
Prepared by
Ryan Cooper
Published
Last reviewed
Topics
Waterproof Testing

Key Findings

The ETENWOLF FL2 flashlight passed IPX4 waterproof validation — all 3 samples showed zero internal moisture ingress after 3 minutes of multi-angle low-pressure water spray.

  • Product: FL2 Flashlight
  • Report No.: 2025110301
  • Test Date: 2025-11-03
  • Standard: Internal Control Standard (IPX4 criteria)
  • Samples: 3 PCS
  • Test Type: Reliability Test
  • Equipment: Box-type oscillating tube high-pressure water spray integrated machine
  • Result: PASS — No water ingress detected on disassembly inspection

Test Overview

Field Details
Product No./Name Flashlight
Model / Type Specification FL2
Report No. 2025110301
Test Date 2025-11-03
Sample Quantity / No. 3 PCS
Type of Test Reliability Test
Test Standard Internal Control Standard
Test Purpose Evaluate whether the sample’s waterproof performance meets IPX4 rating requirements
Product Link ETENWOLF FL2 Flashlight

Test Equipment & Setup

Parameter Details
Test Equipment Box-type oscillating tube high-pressure water spray integrated machine
Room Temperature 23 °C
Relative Humidity 60 %
Power Source 12 V
Spray Duration 3 minutes continuous
Spray Angle Arbitrary angle (all directions)
Water Pressure Low-pressure water column

Test Procedure

  1. Pre-test: Record ambient temperature (23 °C) and relative humidity (60 %). Verify power source is set to 12 V. Confirm 3 FL2 flashlight samples are fully assembled and in normal operating condition.
  2. Sample Placement: Position samples inside the box-type oscillating tube spray machine per standard placement orientation (see test placement photo).
  3. Spray Test: Apply low-pressure water column spray at arbitrary angles to the enclosure continuously for 3 minutes.
  4. Post-test Disassembly: Immediately after spray ends, disassemble each sample and visually inspect the interior for any signs of water ingress or moisture traces.
  5. Acceptance Criteria: No water traces or moisture detected inside the enclosure. Sample must meet IPX4 waterproof rating — protected against water spray from any direction.

Test Data & Results

Item Description
Test Title Flashlight Waterproof Performance Test
Product No./Name Flashlight
Report No. 2025110301
Test Date 2025-11-03
Model / Type Specification FL2
Sample Quantity / No. 3 PCS
Type of Test ■ Reliability Test (可靠性测试); EMC Test — No; Safety Test — No; Functional Test — No
Test Standard Internal Control Standard
Test Purpose Evaluate whether the sample’s waterproof performance meets IPX4 rating requirements
Test Procedure Low-pressure water column spray at arbitrary angles; continuous 3 minutes; immediate disassembly inspection for water ingress
Test Criteria Evaluate sample’s protective capability against water spray
Test Equipment Box-type oscillating tube high-pressure water spray integrated machine
Test Conditions Room Temp: 23 °C, Humidity: 60 %, Power Source: 12 V
Remarks / Notes
Test Pictures — Pre-test Pre-test sample photo documented
Test Pictures — Equipment Control Equipment control panel photo documented
Test Pictures — Sample Placement Sample placement photo documented
Test Pictures — During Test In-progress spray photo documented
Test Pictures — Post Disassembly Interior inspection photo — no water ingress confirmed
Test Result After waterproof testing, no water traces found inside samples; IPX4 waterproof rating requirements are met
Pass / Fail / For Reference ■ For Reference Only (供参考)

Observation: All 3 FL2 flashlight samples were disassembled immediately after the 3-minute multi-angle spray test. Internal inspection confirmed zero moisture or water traces in all units, demonstrating compliance with IPX4 enclosure protection criteria.

Conclusion

Field Details
Result For Reference Only (■ 供参考)
Test Standard Internal Control Standard — IPX4 criteria
Test Conditions 23 °C, 60 % RH, 12 V power; 3-minute multi-angle low-pressure spray
Samples Tested 3 PCS FL2 Flashlight
Verdict All samples showed no internal water ingress. IPX4 waterproof performance requirements are satisfied.

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-11-03
Checked By (审核/日期) Zhang Ronggui 2025-11-03
Approved By (核准/日期) Mai Shaoqiang 2025-11-03
Form No. BTK-R-Q142/AO

Frequently Asked Questions

What does IPX4 waterproof rating mean for the ETENWOLF FL2 flashlight?

IPX4 means the FL2 flashlight is protected against water spray from any direction. It can withstand low-pressure water splashes at arbitrary angles without water entering the enclosure, making it suitable for use in rain or wet outdoor conditions.

How was the FL2 flashlight waterproof test conducted?

The FL2 was subjected to continuous low-pressure water column spray at arbitrary angles for 3 minutes using a box-type oscillating tube spray machine at 23 °C and 60 % relative humidity. Each sample was immediately disassembled after the test and inspected internally for any signs of water ingress.

Did the ETENWOLF FL2 flashlight pass the IPX4 waterproof test?

Yes. All 3 FL2 flashlight samples tested on 2025-11-03 showed no internal water traces after the 3-minute spray test. The results confirm the FL2 meets IPX4 waterproof rating requirements. The report is classified as for reference only per internal quality documentation procedures.

What standard was used for the FL2 flashlight waterproof test?

The test was conducted against ETENWOLF’s internal control standard aligned with IPX4 enclosure protection criteria. IPX4 is defined under the IEC 60529 international standard for degrees of protection provided by enclosures.