ETENWOLF CL6 Camping Lantern Operating Temperature Test Report (−20 °C to 70 °C)

Document Overview

Key Findings The ETENWOLF CL6 Camping Lantern passed high-temperature (70 °C) and low-temperature (−20 °C) operating tests, maintaining normal illumination at all brightness levels with no functional anomalies observed. Product: CL6 Camping Lantern Report No.: 20260111-001 Test Date: 2026-01-11 Temperature Range: −20 °C to 70…

Document type
Test Report
Prepared by
Ryan Cooper
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The ETENWOLF CL6 Camping Lantern passed high-temperature (70 °C) and low-temperature (−20 °C) operating tests, maintaining normal illumination at all brightness levels with no functional anomalies observed.

  • Product: CL6 Camping Lantern
  • Report No.: 20260111-001
  • Test Date: 2026-01-11
  • Temperature Range: −20 °C to 70 °C
  • Samples: 2 pcs
  • Test Standard: Internal Control Standard
  • Verdict: Pass (■ 合格)

Test Overview

Field Details
Product No. / Name Camping Lantern
Model / Type Specification CL6
Report No. 20260111-001
Test Date 2026-01-11
Sample Quantity / No. 2 pcs
Test Type Reliability Test (■ 可靠性测试)
Test Standard Internal Control Standard (内控标准)
Test Purpose Evaluate the effect of high- and low-temperature storage conditions on the operational temperature performance of the samples
Test Procedure Summary Discharge condition after samples stabilise at −20 °C and 70 °C environments
Pass Criterion Samples operate normally at the specified ambient temperatures
Product URL N/A

Test Equipment & Setup

Item Details
Test Equipment Thermal Shock Chamber (冷热冲击箱)
Room Temperature 23 °C
Room Humidity 60 %
High-Temperature Set Point 70 °C
Low-Temperature Set Point −20 °C
Soak Duration (each condition) 2 hours

Test Procedure

  1. Pre-test: Record sample IDs (CL2-1#, CL2-2#) and confirm ambient conditions — 23 °C, 60 % RH.
  2. High-temperature conditioning: Place samples in thermal shock chamber set to 70 °C; allow to stabilise for 2 hours.
  3. High-temperature functional check: Power on samples; cycle through all brightness levels; verify switching and power-on/off button response.
  4. Low-temperature conditioning: Set chamber to −20 °C; allow samples to stabilise for 2 hours.
  5. Low-temperature functional check: Power on samples; cycle through all brightness levels; verify switching and power-on/off button response.
  6. Post-test: Return samples to room temperature; document observations, capture test pictures, and record results.
  7. Acceptance criterion: Samples must illuminate normally at all brightness levels and respond correctly to all button inputs throughout the specified temperature range.

Test Data & Results

Sample ID Test Condition Issue Description / Observations
CL2-1#–2# High-Temperature Illumination Test (70 °C) After storing the samples in a 70 °C environment for 2 hours, powering on the lantern showed no change in brightness at any level; power-on/off button switching operated normally.
CL2-1#–2# Low-Temperature Illumination Test (−20 °C) After storing the samples in a −20 °C environment for 2 hours, powering on the lantern showed no change in brightness at any level; power-on/off button switching operated normally.

Overall Test Result: Samples passed the high- and low-temperature test procedure; normal illumination was achieved at all specified operating temperatures.

Test Pictures: Captured on-site during testing (see original report appendix).

Conclusion

Field Details
Result ■ Pass (合格)
Standard Internal Control Standard
Test Conditions −20 °C and 70 °C, 2-hour soak each; ambient 23 °C / 60 % RH
Samples Tested 2 pcs (CL2-1#, CL2-2#)
Verdict The CL6 Camping Lantern operates normally across the full −20 °C to 70 °C temperature range with no brightness variation or control anomalies.

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2026-01-11
Checked By (审核/日期) Zhang Ronggui 2026-01-11
Approved By (核准/日期) Mai Shaoqiang 2026-01-11
Form No. BTK-R-Q142/AO

Frequently Asked Questions

What temperature range does the ETENWOLF CL6 Camping Lantern operate in?

The CL6 is validated to operate normally from −20 °C to 70 °C. Both extremes were tested with a 2-hour stabilisation soak, and the lantern maintained full brightness at all levels with no control issues.

What test standard was used for the CL6 operating temperature test?

The test followed ETENWOLF’s Internal Control Standard (内控标准). The acceptance criterion requires the lantern to illuminate normally at all brightness levels throughout the specified temperature range.

How long were the CL6 samples conditioned before the temperature test?

Samples were placed in a thermal shock chamber and allowed to stabilise for 2 hours at each target temperature (−20 °C and 70 °C) before functional checks were performed.

Did the CL6 Camping Lantern pass the operating temperature test?

Yes. Both test samples (CL2-1# and CL2-2#) passed. No brightness variation was observed at any level, and button switching functioned correctly at both −20 °C and 70 °C.