ETENWOLF CL3 Camping Lantern Drop Test Report (100 cm, 6-Face, Engineering Change Verification)

Document Overview

Key Findings The CL3 camping lantern passed all drop test requirements after six free-fall drops from 100 cm onto a concrete surface, showing only minor surface scratches with no structural cracking, deformation, or functional defects. Product: CL3 Camping Lantern (CL3-露营灯) Report No.: 20260421-001 Test Date:…

Document type
Test Report
Prepared by
Ryan Cooper
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

The CL3 camping lantern passed all drop test requirements after six free-fall drops from 100 cm onto a concrete surface, showing only minor surface scratches with no structural cracking, deformation, or functional defects.

  • Product: CL3 Camping Lantern (CL3-露营灯)
  • Report No.: 20260421-001
  • Test Date: 2026-04-21
  • Drop Height: 100 cm
  • Drop Faces: 6 orientations (front, back, left, right, top, bottom)
  • Surface: Concrete floor, free-fall
  • Samples: 2 PCS
  • Verdict: Pass

Test Overview

Field Details
Test Type Drop Test (跌落试验) — Mechanical Reliability
Standard / Test Basis Engineering change verification (工程变更)
Report No. 20260421-001
Page 1.0
Date 2026-04-21
Product Name CL3 Camping Lantern (CL3-露营灯)
Manufacturer BTK
Surface Treatment
Sample Quantity 2 PCS
Test Reason Engineering Change (工程变更) ■
Test Purpose Evaluate the product’s resistance to drop impact and assess overall reliability
Lab Environment Temperature: 22 °C; Humidity: 55% RH

Test Equipment & Setup

Item Details
Instrument Name Single-arm drop testing machine (单臂跌落试验机)
Ancillary Equipment Power controller (电源控制器)
Drop Height 100 cm
Drop Surface Concrete floor
Drop Orientations 6 faces — front (正面), back (背面), left side (左侧面), right side (右侧面), top (顶面), bottom (底面)
Drop Method Free-fall from each orientation
Sample Weight Recorded on test sheet (field present, value not specified in source data)
Test Class Recorded on test sheet (field present, value not specified in source data)

Test Procedure

  1. Pre-test inspection: Visually inspect both samples for any pre-existing damage; confirm power-on functionality and mode-switching operation; record sample weight and test class.
  2. Environment setup: Verify lab conditions — temperature 22 °C, humidity 55% RH.
  3. Equipment setup: Configure the single-arm drop testing machine to a drop height of 100 cm above a concrete surface.
  4. Drop 1 — Front face (正面): Position sample in front-face orientation; release for free-fall onto concrete.
  5. Drop 2 — Back face (背面): Reposition sample; release for free-fall.
  6. Drop 3 — Left side (左侧面): Reposition sample; release for free-fall.
  7. Drop 4 — Right side (右侧面): Reposition sample; release for free-fall.
  8. Drop 5 — Top face (顶面): Reposition sample; release for free-fall.
  9. Drop 6 — Bottom face (底面): Reposition sample; release for free-fall.
  10. Post-test inspection: Inspect housing for cracking, deformation, or structural damage; power on to verify illumination (no flicker); test mode/gear switching; verify charging function; check that all screws are secure.
  11. Acceptance criteria: Housing must show no cracking or breakage; main structural body must be free of defects; all functional features must operate normally after all six drops.

Test Data & Results

Inspection Item Observation After 6 Drops Result
Lamp head cracking No cracking on lamp head (灯头无开裂) Pass
Lamp shade damage No damage to lamp shade (灯罩无受损) Pass
Power-on illumination Lights immediately upon power-on, no flickering (通电即亮无频闪) Pass
Screw retention No screws loose (螺丝无松脱) Pass
Charging function Charging function normal (充电功能正常) Pass
Housing / structural integrity Only minor surface scratches present; no cracking or deformation of outer shell or main body structure Pass
Mode / gear switching Gear switching smooth and normal (档位切换顺畅) Pass
Overall functional assessment No functional defects detected (无功能性不良) Pass

Overall test result summary: After drop testing, only minor scratches were observed on the exterior. The structural body showed no cracking or deformation. The unit powered on normally, mode switching was smooth, and the charging function operated correctly. No functional defects were identified. The product is judged Qualified (合格).

Conclusion

Field Details
Result ■ Pass (合格Pass)
Drop Standard 6 free-fall drops from 100 cm onto concrete, covering all 6 face orientations
Acceptance Conditions No housing cracking or breakage; main body structure defect-free; all functions normal post-drop
Samples Tested 2 PCS — CL3 Camping Lantern
Manufacturer BTK
Verdict PASS

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Review / Check (审查) Zhang Ronggui
Tester (测试) Li Guanghua
Form Number (表单编号) BTK-R-Q-087A/1

Frequently Asked Questions

What does the CL3 drop test evaluate?

The drop test evaluates the CL3 camping lantern’s ability to withstand mechanical shock from accidental drops. The unit is subjected to six free-fall drops from 100 cm onto a concrete surface — one drop for each face orientation (front, back, left, right, top, bottom) — and then inspected for structural damage and functional integrity.

What are the pass/fail criteria for this test?

The product passes if the housing shows no cracking or breakage, the main structural body is free of defects, and all functions (illumination, mode switching, charging) operate normally after all six drops. Minor cosmetic scratches are acceptable and do not constitute a failure.

Why was this test triggered as an engineering change verification?

The report indicates the test reason was an engineering change (工程变更) rather than a new product qualification or routine test. This means a design or manufacturing modification was made to the CL3, and the drop test was conducted to confirm the change did not negatively affect the unit’s mechanical reliability.

Who manufactured the CL3 camping lantern tested in this report?

The CL3 camping lantern tested in report 20260421-001 was manufactured by BTK. The test was conducted under lab conditions of 22 °C and 55% RH, with two production samples evaluated.

Related Products

Explore other products in the Lighting Gear line from ETENWOLF:

For international drop test and mechanical reliability standards, refer to: