Key Findings

All 10 production samples of the ETENWOLF FL1 Kids Rechargeable Flashlight were tested for illuminance at 1 metre (0° angle, spotlight mode) on 2025-08-19, with results ranging from 1,026 lux to 1,258 lux, recorded for reference.

  • Report No.: 2025081901
  • Test Date: 2025-08-19
  • Sample Size: 10 PCS
  • Test Distance: 1 metre, 0° angle, white light spotlight mode
  • Illuminance Range: 1,026 lux – 1,258 lux
  • Average Illuminance: 1,144.9 lux
  • Test Standard: Internal standard
  • Verdict: For Reference Only

Test Overview

Field Details
Test Type Illuminance and Light Beam Testing (Reliability Test)
Test Standard Internal Standard
Report No. 2025081901
Test Date 2025-08-19
Product No. / Name FL1 Kids Rechargeable Flashlight (儿童手电筒)
Model / Specification FL1
Manufacturer ETENWOLF
Sample Quantity / No. 10 PCS (FL1-1# through FL1-10#)
Test Environment Room temperature 23 °C, relative humidity 60 %
Test Purpose Evaluate the illuminance value of the FL1 flashlight

Test Equipment & Setup

Item Details
Test Equipment Illuminance Meter (照度计)
Measurement Distance 1 metre
Measurement Angle 0° (on-axis)
Light Mode White light, spotlight / focused beam mode
Device State Powered on
Ambient Temperature 23 °C
Relative Humidity 60 %

Test Procedure

  1. Pre-test: Verify ambient conditions are at room temperature (23 °C) and 60 % relative humidity. Confirm all 10 samples are fully charged and functional.
  2. Setup: Position the illuminance meter at a fixed distance of 1 metre from the flashlight lens, aligned at 0° on the central axis.
  3. Activation: Power on each sample and set to white light spotlight (focused beam) mode.
  4. Measurement: Record the illuminance value (lux) displayed on the meter for each sample individually.
  5. Repeat: Perform the measurement for all 10 samples (FL1-1# through FL1-10#) in sequence.
  6. Post-test: Power off all samples. Document readings and observations in the test record.
  7. Acceptance Criteria: No numeric pass/fail threshold defined; results are recorded for reference only (internal standard).

Test Data & Results

Sample No. Distance Illuminance (LUX)
FL1-1# 1 m 1,037
FL1-2# 1 m 1,169
FL1-3# 1 m 1,224
FL1-4# 1 m 1,258
FL1-5# 1 m 1,142
FL1-6# 1 m 1,048
FL1-7# 1 m 1,197
FL1-8# 1 m 1,254
FL1-9# 1 m 1,026
FL1-10# 1 m 1,094
Average 1,144.9
Minimum 1,026
Maximum 1,258

Observations: All 10 samples produced illuminance readings above 1,000 lux at 1 metre in spotlight mode. The spread of 232 lux between the lowest (FL1-9#: 1,026 lux) and highest (FL1-4#: 1,258 lux) reading represents approximately 20 % variation across the production batch, which is typical for LED-based consumer flashlights. No anomalous readings or sample failures were noted during testing. Results are designated for reference only under the applicable internal standard.

Conclusion

Field Details
Result Illuminance values: 1,026 – 1,258 lux at 1 m
Standard Internal Standard (no numeric pass/fail threshold)
Test Conditions 23 °C, 60 % RH; white light spotlight mode; 1 m, 0°
Samples Tested 10 PCS (FL1-1# through FL1-10#)
Verdict ■ For Reference Only (供参考)

Document Information

Role Name Date
Tested By (测试/日期) Zhang Ronggui 2025-08-19
Reviewed By (审核/日期)
Approved By (核准/日期)

Source File: FL1儿童手电筒量产品照度测试报告 20250819.xlsx  |  Sheet: 照度 (Sheet 1 of 1)  |  Article Author: Ryan Cooper

Frequently Asked Questions

What does the FL1 illuminance test measure?

The test measures the illuminance (in lux) produced by the FL1 flashlight at a fixed distance of 1 metre on the central axis (0°) while the light is set to white light spotlight mode. Lux is a measure of luminous flux per unit area received at a surface, giving a practical indication of how bright the beam is at that distance.

Why do the 10 samples show different lux readings?

Unit-to-unit variation in LED output, lens alignment, and reflector manufacturing tolerances naturally produce a spread in illuminance values across a production batch. The 232-lux range observed here (approximately 20 % of the mean) is within the normal range for consumer-grade LED flashlights and does not indicate defective units.

Is there a pass/fail threshold for this test?

No. This report was conducted against an internal standard with no defined numeric acceptance limit. The verdict is “For Reference Only,” meaning the data is used to characterise production output and inform future specifications rather than to accept or reject individual units.