ETENWOLF FL2 Flashlight Illuminance & Laser Spot Test Report (1 m / 5 m, 3 Samples)

Document Overview

Key Findings The ETENWOLF FL2 flashlight was evaluated for illuminance output in flood and spotlight modes at 1 m, and laser spot dimensions at 5 m, with all three samples performing consistently — results recorded for reference. Product: ETENWOLF FL2 Flashlight Report No.: 2025103101 Test…

Document type
Test Report
Prepared by
Ryan Cooper
Published
Last reviewed
Topics
Illuminance Testing

Key Findings

The ETENWOLF FL2 flashlight was evaluated for illuminance output in flood and spotlight modes at 1 m, and laser spot dimensions at 5 m, with all three samples performing consistently — results recorded for reference.

  • Product: ETENWOLF FL2 Flashlight
  • Report No.: 2025103101
  • Test Date: 2025-10-31
  • Samples: 3 PCS (units 4#, 5#, 6#)
  • Flood illuminance @ 1 m: 219 – 231 lux across samples
  • Spot illuminance @ 1 m: 1,520 – 1,800 lux across samples
  • Laser spot length @ 5 m: 12.6 – 15.9 mm
  • Laser spot width @ 5 m: 3.7 – 4.6 mm
  • Overall verdict: For reference only

Test Overview

Field Detail
Test Type Illuminance Testing (Reliability Test)
Report No. 2025103101
Test Date 2025-10-31
Product No. / Name Flashlight
Model ETENWOLF FL2
Sample Quantity / No. 3 PCS (4#, 5#, 6#)
Test Standard Internal Standard — Range & Luminous Intensity Uniformity Evaluation
Test Purpose Evaluate the illuminance values and laser spot diameter of the FL2 flashlight
Test Conditions Room Temperature: 23 °C, Relative Humidity: 60%

Test Equipment & Setup

Item Detail
Test Equipment Illuminance Meter (Lux Meter, unit: LX)
Test Environment Dark room (anechoic lighting environment)
Measurement Distance — Illuminance 1 m from light source along optical axis
Measurement Distance — Laser Spot 5 m from laser source
Temperature 23 °C
Relative Humidity 60%

Test Procedure

  1. Pre-test: Confirm samples 4#, 5#, and 6# are fully charged and functional. Set up the dark room environment at 23 °C and 60% RH.
  2. Illuminance test (flood & spot, 1 m): Position the illuminance meter at 1 m from the flashlight along the optical axis. Activate flood light mode; record the maximum lux value at the beam center. Repeat for spotlight mode.
  3. Laser spot measurement (5 m): Project the laser beam onto a flat target surface at 5 m. Measure and record the length and width of the laser spot center in millimeters.
  4. Repeat: Perform all measurements for each of the three samples (4#, 5#, 6#).
  5. Post-test: Document all readings, photographs, and observations. Evaluate against acceptance criteria.
  6. Acceptance criteria: Results recorded for reference only (■ For reference only). No pass/fail threshold applied in this report cycle.

Test Data & Results

Illuminance Measurements at 1 m (Flood & Spotlight)

Sample No. Distance (m) Light Mode Illuminance (LUX)
4# 1 Flood Light 219
5# 1 Flood Light 215
6# 1 Flood Light 231
4# 1 Spotlight 1,520
5# 1 Spotlight 1,800
6# 1 Spotlight 1,764

Laser Spot Diameter Measurements at 5 m

Sample No. Distance (m) Light Mode Spot Length (mm) Spot Width (mm)
4# 5 Laser 12.6 4.2
5# 5 Laser 15.9 4.6
6# 5 Laser 13.7 3.7

Observations: Flood illuminance across the three samples ranged from 215 to 231 lux, showing good consistency (spread of 16 lux, ~7%). Spotlight illuminance ranged from 1,520 to 1,800 lux; sample 5# returned the highest reading. Laser spot dimensions at 5 m were consistent in width (3.7 – 4.6 mm) with slightly more variation in length (12.6 – 15.9 mm), consistent with typical elliptical laser beam profiles. Test images were captured for the 1 m illuminance test and the 5 m laser test as supplementary documentation.

Conclusion

Parameter Standard / Criteria Test Conditions Samples Verdict
Flood Illuminance @ 1 m Internal Standard 23 °C, 60% RH, dark room, 1 m 4#, 5#, 6# For Reference Only
Spotlight Illuminance @ 1 m Internal Standard 23 °C, 60% RH, dark room, 1 m 4#, 5#, 6# For Reference Only
Laser Spot Diameter @ 5 m Internal Standard 23 °C, 60% RH, dark room, 5 m 4#, 5#, 6# For Reference Only

Document Information

Role Name (Pinyin) Date
Tested By Li Guanghua 2025-10-31
Checked By Zhang Ronggui 2025-10-31
Approved By Mai Shaoqiang 2025-10-31
Field Detail
Source File FL2手电筒-照度激光测试_2025.10.31.xlsx
Sheet Name 照度值测试 (Illuminance Value Test)
Report No. 2025103101
Total Sheets 1

Frequently Asked Questions

What is the illuminance of the ETENWOLF FL2 flashlight in spotlight mode?

At a distance of 1 m along the optical axis in a dark room, the FL2 flashlight produced spotlight illuminance readings of 1,520 lux (sample 4#), 1,800 lux (sample 5#), and 1,764 lux (sample 6#) — averaging approximately 1,695 lux across the three tested units.

How large is the FL2 laser spot at 5 meters?

At 5 m, the FL2 laser spot measured 12.6 – 15.9 mm in length and 3.7 – 4.6 mm in width across three samples, producing an elongated elliptical beam profile typical of focused laser emitters.

What flood light illuminance does the FL2 flashlight produce?

In flood light mode at 1 m, the FL2 produced 219 lux, 215 lux, and 231 lux for samples 4#, 5#, and 6# respectively — a tight range indicating consistent performance across units.

Did the ETENWOLF FL2 pass the illuminance test?

This test cycle was conducted against an internal standard for range and luminous intensity uniformity evaluation. The results are recorded as "For reference only" — no formal pass/fail threshold was applied, and all data is retained as baseline performance documentation for the FL2 model.