Document Overview
Key Findings Both CL3 camping lantern samples measured static leakage current well below 2 μA in the powered-off state, confirming negligible quiescent drain from the battery circuit. Product: CL3 Camping Lantern Report No.: 20260423-001 Test Date: 2026-04-23 Samples: 2 PCS Test Type: Reliability Test —…
- Document type
- Test Report
- Prepared by
- Ryan Cooper
- Published
- Last reviewed
- Topics
- Battery Testing
Key Findings
Both CL3 camping lantern samples measured static leakage current well below 2 μA in the powered-off state, confirming negligible quiescent drain from the battery circuit.
- Product: CL3 Camping Lantern
- Report No.: 20260423-001
- Test Date: 2026-04-23
- Samples: 2 PCS
- Test Type: Reliability Test — Static Leakage Current
- Standard: Internal Standard
- Result: For Reference Only
- Sample 1#: 1.4 μA (powered off)
- Sample 2#: 1.6 μA (powered off)
Test Overview
| Field | Detail |
|---|---|
| Product No. / Name | Camping Lantern |
| Model / Type Specification | CL3 |
| Report No. | 20260423-001 |
| Test Date | 2026-04-23 |
| Sample Quantity / No. | 2 PCS |
| Type of Test | Reliability Test |
| Test Standard | Internal Standard |
| Test Purpose | Measure the static leakage current of the product in the powered-off state |
| Test Procedure (summary) | With the product switched off, measure the static current of the product |
| Pass/Fail Criterion | / |
Test Equipment & Setup
| Item | Detail |
|---|---|
| Test Equipment | Multimeter |
| Ambient Temperature | 23 °C |
| Relative Humidity | 60 % |
| Product State During Test | Powered off (shutdown) |
| Measured Parameter | Static leakage current (μA) |
Test Procedure
- Pre-test: Confirm the product is fully assembled and that the battery is installed. Record ambient temperature (23 °C) and humidity (60 %) in the test log.
- Setup: Set the multimeter to the micro-ampere (μA) current measurement range.
- Power off: Switch the CL3 unit to the off (shutdown) state.
- Measurement: Connect the multimeter in series with the battery circuit and record the static leakage current reading for each sample.
- Post-test: Disconnect the multimeter, return the unit to its normal condition, and record all readings in the data table.
- Acceptance Criterion: No formal pass/fail limit is defined for this test; results are recorded for reference only.
Test Data & Results
| Sample No. | State | Current (μA) |
|---|---|---|
| 1# | Powered Off | 1.4 |
| 2# | Powered Off | 1.6 |
Observations: Both samples exhibited very low static leakage current in the powered-off state. The readings of 1.4 μA and 1.6 μA indicate that the CL3’s battery protection circuit draws negligible quiescent current, which is consistent with good standby power management for a battery-operated camping lantern. No anomalies were observed during measurement.
Conclusion
| Item | Detail |
|---|---|
| Test Item | Static Leakage Current |
| Applied Standard | Internal Standard |
| Test Conditions | 23 °C, 60 % RH, product powered off |
| Samples Tested | 2 PCS (1#, 2#) |
| Results | 1# — 1.4 μA; 2# — 1.6 μA |
| Verdict | For Reference Only |
Document Information
| Role | Name | Date |
|---|---|---|
| Tested By | — | — |
| Checked By | — | — |
| Approved By | — | — |
Source File: CL3露营灯-静态电流测试_2026.4.23.xlsx | Sheet: 噪音测试 (Sheet 1 of 1)
Frequently Asked Questions
What is static leakage current and why does it matter for a camping lantern?
Static leakage current is the tiny amount of current a battery-powered device draws from its battery even when switched off. For a camping lantern like the CL3, keeping this value low — in the single-digit microamp range — means the battery loses virtually no charge during storage, so the lantern is ready to use after extended periods without recharging.
What static leakage current did the ETENWOLF CL3 measure?
In this test, Sample 1# measured 1.4 μA and Sample 2# measured 1.6 μA, both recorded with the unit in the powered-off state at 23 °C and 60 % relative humidity.
What test equipment was used to measure the CL3’s static current?
A multimeter configured on the micro-ampere (μA) range was used, connected in series with the battery circuit while the CL3 was switched off.
Did the CL3 pass the static leakage current test?
No formal pass/fail threshold is defined for this test under the internal standard; the results (1.4 μA and 1.6 μA) are recorded for reference only and serve as a baseline for future comparison and product validation.
Related Products
Explore other ETENWOLF lighting gear and related test reports:
- ETENWOLF Official Website
- More reports by Ryan Cooper