Document Overview
Key Findings The ETENWOLF CL6 Camping Lantern completed a 72-hour high/low temperature and humidity cycling test — alternating between 60 °C / 80 % RH and −20 °C — and passed with normal electrical and structural performance on both samples. Report No.: 2026011401 Test Duration:…
- Document type
- Test Report
- Prepared by
- Ryan Cooper
- Published
- Last reviewed
- Topics
- Environmental Testing
Key Findings
The ETENWOLF CL6 Camping Lantern completed a 72-hour high/low temperature and humidity cycling test — alternating between 60 °C / 80 % RH and −20 °C — and passed with normal electrical and structural performance on both samples.
- Report No.: 2026011401
- Test Duration: 72 hours total (18 cycles of 2 h high-temp + 2 h low-temp)
- High-Temperature Condition: 60 °C / 80 % RH for 2 hours per cycle
- Low-Temperature Condition: −20 °C for 2 hours per cycle
- Samples Tested: 2 PCS
- Electrical Performance: Pass (OK)
- Structural Integrity: Pass (OK)
- Overall Verdict: Pass
Test Overview
| Field | Details |
|---|---|
| Report Title | High and Low Temperature and Humidity Cycling Test Report |
| Report No. | 2026011401 |
| Test Date | 2026-01-11 to 2026-01-14 |
| Product Name | CL6 Camping Lantern (CL6露营灯) |
| Manufacturer | BTK |
| Surface Treatment | / |
| Sample Quantity | 2 PCS |
| Test Class / Level | / |
| Test Reason | Other (■其它 other) |
| Laboratory Temperature | 22 °C |
| Laboratory Humidity | 55 % RH |
Test Equipment & Setup
| Item | Details |
|---|---|
| Instrument | Constant Temperature and Humidity Testing Machine (恒温恒湿试验机) |
| High-Temperature Condition | 60 °C / 80 % RH — duration: 2 hours per cycle |
| Low-Temperature Condition | −20 °C — duration: 2 hours per cycle |
| Total Test Duration | 72 hours |
| Acceptance Criterion | After the test, the electrical performance of the sample must be normal |
Test Procedure
- Pre-test: Record laboratory ambient conditions — temperature 22 °C, humidity 55 % RH. Inspect and document the initial electrical and structural condition of both CL6 samples.
- Sample placement: Place 2 PCS CL6 Camping Lanterns inside the constant temperature and humidity test chamber according to the chamber loading diagram.
- Cycle execution: Set the chamber controller to run repeating cycles as follows — Phase A: ramp to 60 °C / 80 % RH, hold for 2 hours; Phase B: ramp to −20 °C (no humidity control), hold for 2 hours. Continue cycling until 72 hours of total test time have elapsed.
- Program monitoring: Verify cycle progression against Program Control Diagram 1 and Program Control Diagram 2 throughout the test.
- Post-test inspection: Remove samples from the chamber after 72 hours. Allow samples to return to ambient conditions. Verify electrical performance and structural integrity against acceptance criteria.
- Acceptance criteria: Electrical performance must be normal (OK) and structural features must be intact (OK) for a Pass verdict.
Test Data & Results
| Evaluation Category | Result |
|---|---|
| Electrical Specification (电气特性) | OK |
| Structural Feature (结构特性) | OK |
Test images documented five stages: pre-test condition, sample placement in chamber, Program Control Diagram 1, Program Control Diagram 2, and post-test condition (测试前 / 样品放置图 / 程序控制图1 / 程序控制图2 / 测试后).
Note: After the test, the electrical performance of both samples was confirmed normal. No structural anomalies were observed.
Conclusion
| Item | Details |
|---|---|
| Test | High and Low Temperature and Humidity Cycling Test |
| Conditions | 60 °C / 80 % RH ↔ −20 °C, 2 h per phase, 72 h total |
| Standard / Requirement | Electrical performance normal after test completion |
| Samples | 2 PCS CL6 Camping Lantern |
| Electrical Result | OK — Pass |
| Structural Result | OK — Pass |
| Overall Verdict | Pass (■合格) |
Document Information
| Role | Name |
|---|---|
| Approval (核准) | — |
| Review (审查) | — |
| Tester (试验人) | Su Yimei (粟仪梅) |
| Form Number | BTK-R-Q-087A/1 |
| Page | 1 |
Frequently Asked Questions
What test conditions were used in the CL6 Camping Lantern temperature and humidity cycling test?
The CL6 was subjected to alternating cycles of 60 °C at 80 % relative humidity (high-temperature phase) and −20 °C (low-temperature phase), each phase lasting 2 hours, for a total of 72 continuous hours. The test was conducted in a constant temperature and humidity chamber with the laboratory ambient set at 22 °C and 55 % RH.
Did the ETENWOLF CL6 Camping Lantern pass the high/low temperature humidity cycling test?
Yes. Both samples of the CL6 Camping Lantern passed the test with an overall verdict of Pass (合格). Electrical performance and structural integrity were both confirmed normal (OK) after 72 hours of temperature and humidity cycling between 60 °C / 80 % RH and −20 °C.
What does the high/low temperature humidity cycling test verify for camping lanterns?
This test verifies the reliability of a camping lantern under extreme environmental conditions — simulating real-world use cases such as sudden temperature swings, condensation from heat and humidity, and exposure to freezing cold. It confirms that the product’s electrical systems and physical structure remain functional after repeated thermal stress cycles.
How many samples of the CL6 were tested and who conducted the test?
Two samples (2 PCS) of the CL6 Camping Lantern were tested. The test was conducted by Su Yimei (粟仪梅) under report number 2026011401, with the test period running from January 11 to January 14, 2026.