ETENWOLF FL2 Flashlight Transportation Vibration Test Report (ISTA-2A, 1 Hour Random)

Document Overview

Key Findings The ETENWOLF FL2 flashlight completed a 1-hour random-axis vibration test per ISTA-2A with no functional failure — all 3 samples powered on normally and illumination was confirmed intact after testing. Test Standard: ISTA-2A Test Duration: 1 hour Test Mode: Random vibration, axes X…

Document type
Test Report
Prepared by
Ryan Cooper
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

The ETENWOLF FL2 flashlight completed a 1-hour random-axis vibration test per ISTA-2A with no functional failure — all 3 samples powered on normally and illumination was confirmed intact after testing.

  • Test Standard: ISTA-2A
  • Test Duration: 1 hour
  • Test Mode: Random vibration, axes X / Y / Z
  • Vibration Frequency: 4 Hz
  • Test Speed (CMP): 240 G
  • Vibration Amplitude: 25.4 mm
  • Samples Tested: 3 pcs
  • Overall Verdict: PASS

Test Overview

Field Detail
Test Type Transportation Vibration Test
Test Standard ISTA-2A
Report Number 2025103001
Page 1
Date 2025-10-30
Product Name ETENWOLF FL2 Flashlight
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 pcs
Test Reason New Product
Test Objective To verify the resistance of the sample under transportation and use environments.
Laboratory Temperature 22 °C
Laboratory Humidity 55% RH

Test Equipment & Setup

Parameter Value
Instrument Name Vibration Testing Machine
Test Mode Random Mode
Test Duration 1 hour
Vibration Axes X, Y, Z (random direction)
Vibration Frequency 4 Hz
Test Speed (CMP) 240 G
Vibration Amplitude 25.4 mm

Test Procedure

  1. Pre-test inspection: Verify all 3 FL2 flashlight samples are in normal working condition — power on, confirm illumination function, inspect exterior for pre-existing damage.
  2. Sample placement: Position samples on the vibration table according to the vibration placement layout (振动摆放) as documented in the test pictures.
  3. Parameter configuration: Set the vibration testing machine to random mode, frequency 4 Hz, amplitude 25.4 mm, speed CMP 240 G, axes X / Y / Z.
  4. Vibration run: Execute the random vibration cycle for a continuous duration of 1 hour across all three axes.
  5. Post-test inspection: Power on each sample, confirm normal startup and illumination with no functional failure; inspect exterior appearance for abnormalities; verify charging function operates normally.
  6. Acceptance criteria: After testing, the product must power on normally with no functional failure. Any sample that fails to illuminate or shows functional defects is recorded as a failure.

Test Data & Results

Item Pre-Test Condition Post-Test Appearance Post-Test Function Charging Result
Sample 1 Normal No abnormality Powers on, illumination normal Normal Pass
Sample 2 Normal No abnormality Powers on, illumination normal Normal Pass
Sample 3 Normal No abnormality Powers on, illumination normal Normal Pass

Test result summary (原文 / Original): FL2手电筒样品经过1小时振动测试后,开机照明无异常。

Translation: After 1 hour of vibration testing, the FL2 flashlight samples powered on with no abnormality in illumination.

Vibration control chart and placement photos were recorded during the test as part of the test picture documentation (测试图片), confirming correct setup and monitoring throughout the run.

Conclusion

Field Detail
Verdict PASS
Standard Applied ISTA-2A
Test Conditions Random vibration, 4 Hz, 240 G CMP, 25.4 mm amplitude, X/Y/Z axes, 1 hour, 22 °C / 55% RH
Samples Evaluated 3 pcs FL2 Flashlight
Judgment ■ Pass   □ Fail   □ Reference
Observation No appearance defects, no functional failures, charging verified normal on all samples after 1 hour of random vibration.

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Review (审查) Zhang Ronggui
Tester (试验人) Li Guanghua
Form Number (表单编号) BTK-R-Q-087A/1

Frequently Asked Questions

What does the ETENWOLF FL2 flashlight vibration test cover?

The test subjects the FL2 flashlight to 1 hour of random-axis (X, Y, Z) vibration at 4 Hz, 240 G CMP, and 25.4 mm amplitude per the ISTA-2A standard. It simulates stresses the product encounters during transportation and normal use to confirm structural and functional integrity.

Did the FL2 flashlight pass the ISTA-2A vibration test?

Yes. All 3 FL2 flashlight samples passed. After completing the full 1-hour vibration run, each unit powered on normally, illumination function was confirmed intact, and charging operated without any abnormality.

What vibration parameters were used in the FL2 transport test?

The test used a random vibration mode with a frequency of 4 Hz, a test speed of 240 G CMP, and an amplitude of 25.4 mm. All three spatial axes (X, Y, Z) were included in the random direction cycle, run continuously for 1 hour at 22 °C and 55% RH.

What are the acceptance criteria for the FL2 vibration test?

A sample passes if, after completing the vibration cycle, it powers on normally and all functions — including illumination and charging — operate without failure. Any sample showing functional defects or structural damage is recorded as a fail.