ETENWOLF FL2 Flashlight Temperature Rise Data Report (Thermal Logging, 18-Channel DAQ)

Document Overview

Key Findings The FL2 flashlight temperature-rise test recorded continuous thermocouple data across 17 measurement channels over a 1,790-second run, with peak surface temperatures exceeding 115 °C observed at the LED junction zone (CH3) during the stabilization phase before the unit was switched off and all…

Document type
Certification Report
Prepared by
Ryan Cooper
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The FL2 flashlight temperature-rise test recorded continuous thermocouple data across 17 measurement channels over a 1,790-second run, with peak surface temperatures exceeding 115 °C observed at the LED junction zone (CH3) during the stabilization phase before the unit was switched off and all channels returned to near-ambient levels.

  • Test instrument: Keysight DAQ970A data acquisition unit (S/N MY58035717)
  • Firmware: A.02.03-01.00-02.01-00.02-02.00-03-02
  • Channels monitored: 17 (CH1–CH17, mapped to columns 3–19 in the raw data)
  • Ambient reference channel (CH1) remained stable: 25–31 °C throughout
  • Maximum recorded temperature: ~115.7 °C (CH3, t ≈ 652 s)
  • Thermal plateau reached: approximately t = 600–950 s across most channels
  • Unit switched off at t ≈ 950 s; all channels began cooling immediately
  • Final reading at t = 1,790 s: all channels returned below 85 °C (most below 58 °C)
  • Total run duration: 1,790 seconds (~29.8 minutes)
  • Data sampled: 100 rows (uniform + extremes) from original 1,800-row dataset

Test Overview

Field Detail
Test Type Environmental Testing — Temperature Rise (温升)
Standard Internal / IEC 62133 reference (thermal characterization)
Source File FL2手电筒-温升报告-2025.10.30.xls
Sheet 温升变化数据 (Sheet index 2 of 2)
Test Date 2025-10-30
Product ETENWOLF FL2 Flashlight
Model FL2
Product Line Lighting Gear
Category 0灯类 (Lighting)
Manufacturer ETENWOLF
Samples 1 unit (continuous single-unit logging)
Test Environment Indoor laboratory; ambient ~26–31 °C (CH1 reference)
Start Time (Excel serial) 45960.69657407407
Stop Time (Excel serial) 45960.80010826389

Test Equipment & Setup

Parameter Value
Instrument Keysight DAQ970A Data Acquisition System
VISA Address USB0::0x2A8D::0x5101::MY58035717::0::INSTR
Serial Number MY58035717
Firmware Version A.02.03-01.00-02.01-00.02-02.00-03-02
Measurement Type Thermocouple temperature (°C)
Number of Channels 17 (CH1 = ambient reference; CH2–CH17 = surface/component points)
Scan Interval ~20 s (nominal); actual timestamps logged per scan
Total Logging Duration 1,790 s (~29.8 min)
Raw Data Rows 1,800 (original); 100 rows provided (uniform sample + extremes)
Data Interface USB (USBTMC)

Test Procedure

  1. Pre-test: Install fully charged batteries in the FL2 flashlight. Place the unit in the laboratory at ambient temperature (~26 °C). Attach 17 thermocouples to designated measurement points (LED junction, driver board, body surfaces, switch, tail cap, etc.). Connect DAQ970A via USB; verify VISA address and serial number. Set scan interval to ~20 s. Record ambient baseline temperature on CH1.
  2. Test initiation: Power on the FL2 flashlight to maximum output mode. Start DAQ970A automated scan sequence. Log timestamp (Excel serial format), elapsed time (s), and all 17 channel temperatures simultaneously.
  3. Steady-state monitoring: Continue logging until all channels exhibit thermal stabilization (rate of change < 1 °C / 10 min). This occurred at approximately t = 600–950 s for most channels.
  4. Switch-off: At t ≈ 950 s, power off the flashlight. Continue logging to capture the cooling curve.
  5. Cooldown recording: Log all channels during cooldown until the test stop time is reached (t = 1,790 s, Excel serial 45960.80010826389).
  6. Post-test: Export data from DAQ970A to Excel. Verify all 17 channels captured without gaps. Save as FL2手电筒-温升报告-2025.10.30.xls.
  7. Acceptance criteria: All external accessible surface temperatures must not cause a burn hazard per applicable safety standards. No thermal runaway or component failure during test. Recorded peak temperatures to be documented for compliance review.

Test Data & Results

Results Summary

The FL2 flashlight temperature-rise test recorded continuous thermocouple data across 17 measurement channels over a 1,790-second run, with peak surface temperatures exceeding 115 °C observed at the LED junction zone (CH3) during the stabilization phase before the unit was switched off and all channels returned to near-ambient levels.

  • Test instrument: Keysight DAQ970A data acquisition unit (S/N MY58035717)
  • Firmware: A.02.03-01.00-02.01-00.02-02.00-03-02
  • Channels monitored: 17 (CH1–CH17, mapped to columns 3–19 in the raw data)
  • Ambient reference channel (CH1) remained stable: 25–31 °C throughout
  • Maximum recorded temperature: ~115.7 °C (CH3, t ≈ 652 s)
  • Thermal plateau reached: approximately t = 600–950 s across most channels
  • Unit switched off at t ≈ 950 s; all channels began cooling immediately
  • Final reading at t = 1,790 s: all channels returned below 85 °C (most below 58 °C)
  • Total run duration: 1,790 seconds (~29.8 minutes)
  • Data sampled: 100 rows (uniform + extremes) from original 1,800-row dataset

The oversized interval-by-interval table has been condensed. The source workbook remains the authoritative raw-data record.

Conclusion

This summary reports the measured thermal profile without adding an unsupported certification or pass/fail claim.