CE-EMC Test Report WTH26H01027992E — ETENWOLF CL5 2-in-1 Camping Flashlight Lantern

Document Overview

Document Overview This page presents the CE Electromagnetic Compatibility (EMC) test report issued for the ETENWOLF CL5 2-in-1 Camping Flashlight. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited electromagnetic compatibility testing laboratory located in Longgang District, Shenzhen, Guangdong, China.…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
Lighting Gear

Document Overview

This page presents the CE Electromagnetic Compatibility (EMC) test report issued for the ETENWOLF CL5 2-in-1 Camping Flashlight. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited electromagnetic compatibility testing laboratory located in Longgang District, Shenzhen, Guangdong, China.

Field Detail
Reference Number WTH26H01027992E
Document Type CE-EMC Test Report
Test Report Form No. TRF EN IEC 55015:2019+A11:2020-EMC-001-V01
Internal Form Reference HCT/RF-23-21
Issuing Laboratory Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Date of Sample Receipt 2026-02-02
Date of Testing 2026-02-02 to 2026-02-04
Date of Issue 2026-02-05
Overall Test Result Pass

The report covers electromagnetic disturbance emissions testing required for CE marking under the EU Radio Equipment Directive and EMC Directive, confirming that the product meets all applicable limits.

Product Information

The product evaluated in this report is the CL5, a 2-in-1 Camping Flashlight and lantern developed by Guangdong Bestek Technology Co., Ltd. and marketed globally under the ETENWOLF brand.

Attribute Detail
Product Name 2-in-1 Camping Flashlight
Model Number CL5
Brand ETENWOLF
Applicant Guangdong Bestek Technology Co., LTD
Applicant Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China

The CL5 is designed as a versatile, rechargeable lighting device suitable for camping, outdoor activities, and emergency use. Its 2-in-1 form factor combines a focused flashlight beam with a 360-degree lantern mode, making it a core product in the ETENWOLF rechargeable lighting range.

Key Details

The CE-EMC test report WTH26H01027992E covers three principal EMC measurement disciplines: conducted disturbance voltage at mains terminals, radiated electromagnetic disturbance, and radiated disturbances. Each section includes measurement uncertainty, applicable limits, EUT setup, instrument configuration, test procedure, equipment list, and recorded test data.

Test Section Standard Applied Result
Disturbance Voltage at Mains Terminals EN IEC 55015:2019+A11:2020 Pass
Radiated Electromagnetic Disturbance EN IEC 55015:2019+A11:2020 Pass
Immunity for Lighting Equipment EN IEC 61547:2023 Pass
Harmonic Current Emissions EN IEC 61000-3-2:2019+A2:2024 Pass
Voltage Fluctuations and Flicker EN 61000-3-3:2013+A2:2021 Pass

The report spans 58 pages in total and was prepared by Snow Zeng and approved by Tony Wu at Waltek Testing Group HCT (Shenzhen) Co., Ltd. Test data, corrected amplitude and margin calculations, and equipment lists are documented within each section of the full report.

Standards & Compliance

The CL5 was evaluated against the following harmonised European standards for electromagnetic compatibility applicable to lighting equipment:

  • EN IEC 55015:2019+A11:2020 — Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment. This is the primary emission standard for the product category.
  • EN IEC 61547:2023 — Equipment for general lighting purposes — EMC immunity requirements. Covers immunity performance for lighting devices in typical electromagnetic environments.
  • EN IEC 61000-3-2:2019+A2:2024 — Limits for harmonic current emissions (equipment input current up to and including 16 A per phase). Ensures the product does not introduce excessive harmonic distortion into the mains supply.
  • EN 61000-3-3:2013+A2:2021 — Limitation of voltage changes, voltage fluctuations, and flicker in public low-voltage supply systems. Applicable to equipment with rated current up to 16 A per phase.

These standards collectively satisfy the technical requirements of the EU EMC Directive 2014/30/EU, supporting the CE marking declaration for the CL5.

Validity & Certification Body

The test report WTH26H01027992E was issued on 2026-02-05 by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an independent third-party testing laboratory. The report remains valid as long as the product design, components, and manufacturing processes remain unchanged from the tested sample received on 2026-02-02.

Field Detail
Laboratory Name Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Laboratory Address Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
Telephone 0755-84616666
Service Hotline 400-0066-989
Email [email protected]
Report Prepared By Snow Zeng
Report Approved By Tony Wu
Date of Issue 2026-02-05
Report Valid For Unchanged product configuration as tested

Any modification to the hardware, firmware, power supply circuitry, or enclosure of the CL5 may require re-testing to maintain CE-EMC compliance. The manufacturer is responsible for ensuring ongoing compliance throughout the product lifecycle.

Frequently Asked Questions

What does the CE-EMC test report WTH26H01027992E confirm for the CL5?
It confirms that the ETENWOLF CL5 2-in-1 Camping Flashlight passed all electromagnetic compatibility emission and immunity tests required for CE marking. The product was tested to EN IEC 55015:2019+A11:2020, EN IEC 61547:2023, EN IEC 61000-3-2:2019+A2:2024, and EN 61000-3-3:2013+A2:2021, with an overall result of Pass.
Which laboratory conducted the EMC testing for the CL5?
The testing was performed by Waltek Testing Group HCT (Shenzhen) Co., Ltd., located in Longgang District, Shenzhen, Guangdong, China. The report was prepared by Snow Zeng and approved by Tony Wu. The laboratory can be contacted at [email protected] or via service hotline 400-0066-989.
What does EN IEC 55015 measure and why does it matter for the CL5?
EN IEC 55015 specifies limits and measurement methods for radio disturbance characteristics of electrical lighting equipment. Compliance ensures the CL5 does not emit electromagnetic interference that could disrupt radios, televisions, or other electronic devices operating nearby.
Will product modifications affect the validity of this CE-EMC report?
Yes. The report is valid only for the product configuration tested on 2026-02-02. Any changes to the circuit design, components, power supply, or enclosure of the CL5 may invalidate the current test results and require a new EMC assessment to maintain CE marking compliance.

Related Documents

For a complete compliance and safety documentation package for the CL5, the following related certification and test report types are recommended alongside CE-EMC report WTH26H01027992E:

  • CE-LVD (Low Voltage Directive) Test Report — Covers electrical safety requirements under EN 62368-1 or EN 60598 series for rechargeable lighting products.
  • CE Declaration of Conformity (DoC) — The formal declaration signed by the manufacturer confirming compliance with all applicable EU directives, referencing this EMC report.
  • UN 38.3 Battery Safety Test Report — Required for the rechargeable lithium battery inside the CL5 for transportation compliance.
  • RoHS Compliance Report — Confirms the product is free from restricted hazardous substances under EU RoHS Directive 2011/65/EU.
  • REACH SVHC Declaration — Confirms compliance with REACH Regulation (EC) No 1907/2006 regarding substances of very high concern.
  • FCC Part 15 Test Report — Required for sale in the United States market, covering unintentional radiator emissions for battery-powered lighting devices.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30
Document Page 31
Document Page 32
Document Page 33
Document Page 34
Document Page 35
Document Page 36
Document Page 37
Document Page 38
Document Page 39
Document Page 40
Document Page 41
Document Page 42
Document Page 43
Document Page 44
Document Page 45
Document Page 46
Document Page 47
Document Page 48
Document Page 49
Document Page 50
Document Page 51
Document Page 52
Document Page 53
Document Page 54
Document Page 55
Document Page 56
Document Page 57
Document Page 58