ETENWOLF CL5 Camping Lantern Temperature Rise Test Report (Sheet: 温升采集数据-2#, 2025-09-30)

Document Overview

Key Findings The CL5 Rechargeable Camping Lantern temperature-rise test captured 3,342 seconds of continuous thermocouple data across 11 measurement channels, with peak temperatures exceeding 115 °C on certain internal nodes before stabilizing at thermal equilibrium. Data logger: Keysight DAQ970A (S/N MY58035717, firmware A.02.03-01.00-02.01-00.02-02.00-03-02) Total logging…

Document type
Certification Report
Prepared by
Ryan Cooper
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The CL5 Rechargeable Camping Lantern temperature-rise test captured 3,342 seconds of continuous thermocouple data across 11 measurement channels, with peak temperatures exceeding 115 °C on certain internal nodes before stabilizing at thermal equilibrium.

  • Data logger: Keysight DAQ970A (S/N MY58035717, firmware A.02.03-01.00-02.01-00.02-02.00-03-02)
  • Total logging duration: ~3,342 s (≈55.7 min)
  • Channels monitored: 11 (CH1–CH11 plus ambient)
  • Peak recorded temperature: 115.7 °C (CH5, ~590 s)
  • Ambient temperature range: 24.9 °C – 31.7 °C
  • Thermal steady-state reached: approximately 500–600 s after start
  • Post-test cool-down phase: visible from ~627 s onward on most channels
  • Sheet: 温升采集数据-2# (sheet index 3 of 3)

Test Overview

Parameter Detail
Test Type Environmental Testing — Temperature Rise (温升)
Standard Internal thermal characterization procedure
Report / File CL5露营灯-温升报告-2025.9.30.xls
Test Date 2025-09-30
Product CL5 Rechargeable Camping Lantern
Manufacturer ETENWOLF
Model CL5
Product Line Lighting Gear
Sheet Name 温升采集数据-2# (Sheet 3 of 3)
Samples 1 unit (single-sample continuous logging)
Test Environment Ambient temperature 24.9 °C – 31.7 °C (logged, uncontrolled lab)

Test Equipment & Setup

Item Detail
Instrument Keysight DAQ970A Data Acquisition System
Serial Number MY58035717
VISA Address USB0::0x2A8D::0x5101::MY58035717::0::INSTR
Firmware Version A.02.03-01.00-02.01-00.02-02.00-03-02
Number of Channels 12 (1 ambient + 11 component measurement points)
Sensor Type Thermocouples (type not specified in raw data)
Logging Start Time (Excel serial) 45930.37381168982
Logging Stop Time (Excel serial) 45930.56715776621
Total Logging Duration ~3,342 s (≈55.7 min)
Sampling Interval ~37 s (nominal), uniform sampling applied
Raw Row Count 3,352 rows (downsampled to 100 uniform + extreme rows for report)
Time Column Format Elapsed seconds (Col 2); Excel date-time serial (Col 1)

Test Procedure

  1. Pre-test: Connect all 11 thermocouples to designated measurement points on the CL5 unit and to the DAQ970A input channels. Verify VISA connection (USB0::0x2A8D::0x5101::MY58035717::0::INSTR) and confirm firmware version A.02.03-01.00-02.01-00.02-02.00-03-02.
  2. Pre-test: Record ambient temperature baseline; confirm unit is at room temperature before energizing.
  3. Pre-test: Configure DAQ970A scan list for all 12 channels (ambient + CH1–CH11) at the required scan rate (~37 s interval).
  4. Procedure: Power on the CL5 lantern at rated operating conditions and simultaneously start the DAQ970A logging sequence.
  5. Procedure: Allow continuous operation until thermal steady-state is confirmed (temperature variation <2 °C over three consecutive readings on all channels).
  6. Procedure: Continue logging through any observed mode transitions or load changes (e.g., dimming cycles, charging events) as evidenced by temperature drops at ~627 s and ~1,667 s in the data.
  7. Procedure: Maintain logging until the instrument stop time (elapsed ~3,342 s).
  8. Post-test: Power off the unit and continue logging cool-down data until stable.
  9. Post-test: Export raw scan data from DAQ970A to .xls format; record address, model, serial number, firmware, start time, and stop time in the header rows.
  10. Acceptance Criteria: All measured temperatures must remain below the maximum rated temperature limits for each component/material. No thermal runaway or irreversible damage to the unit. Ambient temperature must be within the specified test environment range throughout the test.

Test Data & Results

Results Summary

The CL5 Rechargeable Camping Lantern temperature-rise test captured 3,342 seconds of continuous thermocouple data across 11 measurement channels, with peak temperatures exceeding 115 °C on certain internal nodes before stabilizing at thermal equilibrium.

  • Data logger: Keysight DAQ970A (S/N MY58035717, firmware A.02.03-01.00-02.01-00.02-02.00-03-02)
  • Total logging duration: ~3,342 s (≈55.7 min)
  • Channels monitored: 11 (CH1–CH11 plus ambient)
  • Peak recorded temperature: 115.7 °C (CH5, ~590 s)
  • Ambient temperature range: 24.9 °C – 31.7 °C
  • Thermal steady-state reached: approximately 500–600 s after start
  • Post-test cool-down phase: visible from ~627 s onward on most channels
  • Sheet: 温升采集数据-2# (sheet index 3 of 3)

The oversized interval-by-interval table has been condensed. The source workbook remains the authoritative raw-data record.

Conclusion

This summary reports the measured thermal profile without adding an unsupported certification or pass/fail claim.