Document Overview
Key Findings The CL5 Rechargeable Camping Lantern temperature-rise test captured 3,342 seconds of continuous thermocouple data across 11 measurement channels, with peak temperatures exceeding 115 °C on certain internal nodes before stabilizing at thermal equilibrium. Data logger: Keysight DAQ970A (S/N MY58035717, firmware A.02.03-01.00-02.01-00.02-02.00-03-02) Total logging…
- Document type
- Certification Report
- Prepared by
- Ryan Cooper
- Published
- Last reviewed
- Topics
- Environmental Testing
Key Findings
The CL5 Rechargeable Camping Lantern temperature-rise test captured 3,342 seconds of continuous thermocouple data across 11 measurement channels, with peak temperatures exceeding 115 °C on certain internal nodes before stabilizing at thermal equilibrium.
- Data logger: Keysight DAQ970A (S/N MY58035717, firmware A.02.03-01.00-02.01-00.02-02.00-03-02)
- Total logging duration: ~3,342 s (≈55.7 min)
- Channels monitored: 11 (CH1–CH11 plus ambient)
- Peak recorded temperature: 115.7 °C (CH5, ~590 s)
- Ambient temperature range: 24.9 °C – 31.7 °C
- Thermal steady-state reached: approximately 500–600 s after start
- Post-test cool-down phase: visible from ~627 s onward on most channels
- Sheet: 温升采集数据-2# (sheet index 3 of 3)
Test Overview
| Parameter | Detail |
|---|---|
| Test Type | Environmental Testing — Temperature Rise (温升) |
| Standard | Internal thermal characterization procedure |
| Report / File | CL5露营灯-温升报告-2025.9.30.xls |
| Test Date | 2025-09-30 |
| Product | CL5 Rechargeable Camping Lantern |
| Manufacturer | ETENWOLF |
| Model | CL5 |
| Product Line | Lighting Gear |
| Sheet Name | 温升采集数据-2# (Sheet 3 of 3) |
| Samples | 1 unit (single-sample continuous logging) |
| Test Environment | Ambient temperature 24.9 °C – 31.7 °C (logged, uncontrolled lab) |
Test Equipment & Setup
| Item | Detail |
|---|---|
| Instrument | Keysight DAQ970A Data Acquisition System |
| Serial Number | MY58035717 |
| VISA Address | USB0::0x2A8D::0x5101::MY58035717::0::INSTR |
| Firmware Version | A.02.03-01.00-02.01-00.02-02.00-03-02 |
| Number of Channels | 12 (1 ambient + 11 component measurement points) |
| Sensor Type | Thermocouples (type not specified in raw data) |
| Logging Start Time (Excel serial) | 45930.37381168982 |
| Logging Stop Time (Excel serial) | 45930.56715776621 |
| Total Logging Duration | ~3,342 s (≈55.7 min) |
| Sampling Interval | ~37 s (nominal), uniform sampling applied |
| Raw Row Count | 3,352 rows (downsampled to 100 uniform + extreme rows for report) |
| Time Column Format | Elapsed seconds (Col 2); Excel date-time serial (Col 1) |
Test Procedure
- Pre-test: Connect all 11 thermocouples to designated measurement points on the CL5 unit and to the DAQ970A input channels. Verify VISA connection (USB0::0x2A8D::0x5101::MY58035717::0::INSTR) and confirm firmware version A.02.03-01.00-02.01-00.02-02.00-03-02.
- Pre-test: Record ambient temperature baseline; confirm unit is at room temperature before energizing.
- Pre-test: Configure DAQ970A scan list for all 12 channels (ambient + CH1–CH11) at the required scan rate (~37 s interval).
- Procedure: Power on the CL5 lantern at rated operating conditions and simultaneously start the DAQ970A logging sequence.
- Procedure: Allow continuous operation until thermal steady-state is confirmed (temperature variation <2 °C over three consecutive readings on all channels).
- Procedure: Continue logging through any observed mode transitions or load changes (e.g., dimming cycles, charging events) as evidenced by temperature drops at ~627 s and ~1,667 s in the data.
- Procedure: Maintain logging until the instrument stop time (elapsed ~3,342 s).
- Post-test: Power off the unit and continue logging cool-down data until stable.
- Post-test: Export raw scan data from DAQ970A to .xls format; record address, model, serial number, firmware, start time, and stop time in the header rows.
- Acceptance Criteria: All measured temperatures must remain below the maximum rated temperature limits for each component/material. No thermal runaway or irreversible damage to the unit. Ambient temperature must be within the specified test environment range throughout the test.
Test Data & Results
Results Summary
The CL5 Rechargeable Camping Lantern temperature-rise test captured 3,342 seconds of continuous thermocouple data across 11 measurement channels, with peak temperatures exceeding 115 °C on certain internal nodes before stabilizing at thermal equilibrium.
- Data logger: Keysight DAQ970A (S/N MY58035717, firmware A.02.03-01.00-02.01-00.02-02.00-03-02)
- Total logging duration: ~3,342 s (≈55.7 min)
- Channels monitored: 11 (CH1–CH11 plus ambient)
- Peak recorded temperature: 115.7 °C (CH5, ~590 s)
- Ambient temperature range: 24.9 °C – 31.7 °C
- Thermal steady-state reached: approximately 500–600 s after start
- Post-test cool-down phase: visible from ~627 s onward on most channels
- Sheet: 温升采集数据-2# (sheet index 3 of 3)
The oversized interval-by-interval table has been condensed. The source workbook remains the authoritative raw-data record.
Conclusion
This summary reports the measured thermal profile without adding an unsupported certification or pass/fail claim.