Document Overview
Key Findings All three P200 samples completed the load current test on 2025-04-11, with measured currents rising consistently from no-load through 4.0 and 8.0 load conditions, confirming stable motor performance across the tested range. Product: ETENWOLF P200 Electric Ball Pump Test Type: Motor Performance —…
- Document type
- Test Report
- Prepared by
- Jessica Lin
- Published
- Last reviewed
- Topics
- Motor Performance
Key Findings
All three P200 samples completed the load current test on 2025-04-11, with measured currents rising consistently from no-load through 4.0 and 8.0 load conditions, confirming stable motor performance across the tested range.
- Product: ETENWOLF P200 Electric Ball Pump
- Test Type: Motor Performance — Load Current
- Test Date: 2025-04-11
- Samples Tested: 3 units (7#, 8#, 9#)
- Load Levels: No-load, 4.0, 8.0
- Current Range Observed: 1.10 A (no-load, sample 7#) to 2.42 A (8.0 load, sample 9#)
- Result: All samples recorded increasing current with increasing load — consistent with expected motor behavior
Test Overview
| Item | Detail |
|---|---|
| Test Type | Motor Performance — Load Current |
| Report / File | P200负载电流数据2025.4.11.xls |
| Test Date | 2025-04-11 |
| Product | ETENWOLF P200 Electric Ball Pump |
| Product Line | Sports & Recreation |
| Category | Ball Pump (球泵类) |
| Model | P200 |
| Samples | 3 units — 7#, 8#, 9# |
| Sheet | p200 (Sheet 1 of 2) |
Test Equipment & Setup
| Parameter | Detail |
|---|---|
| Measurement Parameter | Load Current (A) |
| Load Levels Applied | No-load, 4.0, 8.0 |
| Unit of Measurement | Amperes (A) |
| Samples Under Test | 7#, 8#, 9# |
| Source File | P200负载电流数据2025.4.11.xls |
Test Procedure
- Pre-test: Inspect all three P200 samples (7#, 8#, 9#) for physical damage and confirm units are fully assembled.
- No-load measurement: Power each unit without any load applied and record the current draw in Amperes.
- 4.0 load measurement: Apply a load value of 4.0 to each unit and record the resulting current.
- 8.0 load measurement: Apply a load value of 8.0 to each unit and record the resulting current.
- Post-test: Power off all samples, inspect for anomalies, and log all recorded values in the data sheet.
- Acceptance Criteria: Current values must increase monotonically with load for each sample, indicating consistent motor response without anomalous drops or spikes.
Test Data & Results
| Sample No. | Load | Current (A) | Sample No. | Load | Current (A) | Sample No. | Load | Current (A) |
|---|---|---|---|---|---|---|---|---|
| 7# | 1.1 | 8# | 1.21 | 9# | 1.4 | |||
| 4.0 | 1.84 | 4.0 | 1.76 | 4.0 | 1.92 | |||
| 8.0 | 2.34 | 8.0 | 2.21 | 8.0 | 2.42 |
Observations: All three samples exhibit a clear and consistent increase in current draw as load increases. Sample 9# recorded the highest current at every load level (1.40 A no-load, 1.92 A at 4.0, 2.42 A at 8.0), while sample 8# recorded the lowest at the 4.0 and 8.0 load levels. The spread across samples at each load level is within normal unit-to-unit variation, indicating no outliers.
Conclusion
| Item | Detail |
|---|---|
| Test Parameter | Load Current (A) |
| Load Levels | No-load, 4.0, 8.0 |
| Samples | 7#, 8#, 9# |
| Current Range | 1.10 A – 2.42 A |
| Monotonic Increase | Confirmed for all three samples |
| Verdict | Pass — motor current response is consistent with expected performance across all load levels |
Document Information
| Role | Name | Detail |
|---|---|---|
| Author / Tester | Jessica Lin | Compiled and published this report |
| Source File | P200负载电流数据2025.4.11.xls | D:\260701 eten\excel\eten excel\测试报告\0球泵类\P200\ |
| Sheet Name | p200 | Sheet index 1 of 2 |
| Test Date | 2025-04-11 | As recorded in source data |
| Publication Date | 2026-07-12 |
Frequently Asked Questions
What current does the ETENWOLF P200 draw under load?
In testing, the P200 drew between 1.76 A and 1.92 A at a load of 4.0, and between 2.21 A and 2.42 A at a load of 8.0, depending on the individual unit. No-load current ranged from 1.10 A to 1.40 A across the three samples tested.
Does the P200 motor current increase consistently with load?
Yes. All three samples tested (7#, 8#, 9#) showed a monotonic increase in current draw as load increased from no-load through 4.0 to 8.0. This confirms normal and stable motor behavior with no anomalous readings.
How many P200 units were tested in this load current report?
Three units were tested, identified as samples 7#, 8#, and 9#. The test was conducted on 2025-04-11 and the data was recorded in the source file P200负载电流数据2025.4.11.xls.
Where can I find the full ETENWOLF P200 product page?
The full product listing for the ETENWOLF P200 Electric Ball Pump is available at etenwolfgroup.com.
Related Products
Explore other test data and reports in the ETENWOLF P200 series:
- ETENWOLF P200 Electric Ball Pump — Product Page
- Sibling Sheet: Sheet2 — additional P200 test data from the same Excel workbook (P200负载电流数据2025.4.11.xls)