Document Overview
Key Findings The ETENWOLF P200 Electric Ball Pump successfully passed all six-face drop tests from 100 cm, with no abnormalities observed in appearance or functionality after impact. Product: ETENWOLF P200 Electric Ball Pump Drop Height: 100 cm Drop Faces: 6 faces (6 drops total) Sample…
- Document type
- Test Report
- Prepared by
- Jessica Lin
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF P200 Electric Ball Pump successfully passed all six-face drop tests from 100 cm, with no abnormalities observed in appearance or functionality after impact.
- Product: ETENWOLF P200 Electric Ball Pump
- Drop Height: 100 cm
- Drop Faces: 6 faces (6 drops total)
- Sample Quantity: 2 PCS
- Test Reason: New product evaluation
- Result: PASS — no appearance or functional defects detected
- Report No.: 2024102501
- Test Date: 2024-10-25
Test Overview
| Field | Detail |
|---|---|
| Test Type | Drop Test (Mechanical Reliability) |
| Report No. | 2024102501 |
| Date | 2024-10-25 |
| Page | 1.0 |
| Product Name | ETENWOLF P200 Electric Ball Pump |
| Manufacturer | BTK |
| Surface Treatment | Not specified |
| Sample Quantity | 2 PCS |
| Test Reason | New Product (■ New Product selected; Engineering Change, Routine Test, Quality Abnormal, Other — not selected) |
| Test Purpose | Evaluate the product’s resistance to drop impact and assess its reliability |
| Laboratory Temperature | 22 °C |
| Laboratory Humidity | 55% RH |
Test Equipment & Setup
| Parameter | Detail |
|---|---|
| Instrument Name | Single-arm drop testing machine |
| Drop Height | 100 cm |
| Number of Drops | 6 faces (6 drops) |
| Sample Weight | Recorded on file (not specified in report) |
| Test Class | Not specified |
Test Procedure
- Pre-test inspection: Visually inspect each of the 2 sample units for pre-existing appearance defects and verify normal functionality before testing.
- Environment setup: Confirm laboratory conditions — temperature 22 °C, humidity 55% RH.
- Instrument setup: Configure the single-arm drop testing machine to a drop height of 100 cm.
- Drop sequence: Subject each sample to 6 consecutive drops, one drop per face (Face 1 through Face 6), following the standard six-face drop sequence.
- Photo documentation: Capture photographs before the first drop, and after each of the six drops (Drop 1, Drop 2, Drop 3, Drop 4, Drop 5, Drop 6).
- Post-test inspection: After all six drops, inspect each sample for any appearance abnormalities (cracks, deformation, detachment, surface damage) and verify that all product functions operate normally.
- Acceptance criteria: After testing, the product appearance and functionality must show no abnormalities. Any defect in appearance or function constitutes a failure.
Test Data & Results
| Stage | Observation |
|---|---|
| Before drop test | Product appearance and functionality normal (pre-test photo documented) |
| Drop 1 (Face 1) | No appearance or functional abnormality |
| Drop 2 (Face 2) | No appearance or functional abnormality |
| Drop 3 (Face 3) | No appearance or functional abnormality |
| Drop 4 (Face 4) | No appearance or functional abnormality |
| Drop 5 (Face 5) | No appearance or functional abnormality |
| Drop 6 (Face 6) | No appearance or functional abnormality |
| Post-test summary | After testing, product appearance and functionality showed no abnormalities |
Test Result Statement: After the drop test, the product appearance and functionality showed no abnormalities (试验结果:产品跌落测试后,产品外观功能无异常).
Conclusion
| Field | Detail |
|---|---|
| Result | ■ Pass (合格) |
| Fail | Not selected |
| Reference | Not selected |
| Test Standard / Conditions | Single-arm drop test machine; 100 cm drop height; 6 faces; Lab: 22 °C / 55% RH |
| Product | ETENWOLF P200 Electric Ball Pump |
| Samples Tested | 2 PCS |
| Verdict | PASS — No appearance or functional abnormalities detected after six-face drop from 100 cm |
Document Information
| Role | Name |
|---|---|
| Approval (核准) | — |
| Review / Check (审查) | Mai Shaoqiang |
| Tester (试验人) | Zhang Ronggui |
| Form Number (表单编号) | BTK-R-Q-087A/1 |
Frequently Asked Questions
What drop height was used in the ETENWOLF P200 drop test?
The ETENWOLF P200 Electric Ball Pump was tested at a drop height of 100 cm using a single-arm drop testing machine, covering all six faces of the product for a total of six drops.
Did the ETENWOLF P200 pass the drop test?
Yes. The ETENWOLF P200 passed the six-face drop test from 100 cm with no appearance or functional abnormalities detected on either of the two samples tested.
How many samples were used in the P200 drop test?
Two production samples (2 PCS) of the ETENWOLF P200 Electric Ball Pump were used in this drop test evaluation, conducted under new product qualification testing.
What are the acceptance criteria for the P200 drop test?
The acceptance criterion requires that after all six drops from 100 cm, the product must show no abnormalities in either appearance or functionality. Both samples met this criterion, resulting in a PASS verdict.