IEC 62133-2 CB Test Report – ETENWOLF P200 Lithium-Ion Battery Pack (Report No. 211-282250758-000)

Document Overview

Document Overview This page presents the official CB Test Report issued under the IECEE CB Scheme for the lithium-ion battery pack used in the ETENWOLF P200 electric ball pump. The report was prepared by TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch and…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
Sports & Recreation

Document Overview

This page presents the official CB Test Report issued under the IECEE CB Scheme for the lithium-ion battery pack used in the ETENWOLF P200 electric ball pump. The report was prepared by TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch and issued under the responsibility of the National Certification Body (NCB) TÜV SÜD PSB Pte. Ltd., located at 15 International Business Park, TÜV SÜD@IBP, Singapore 609937.

Field Details
Report Number 211-282250758-000
Date of Issue 2025-10-11
Total Pages 24 pages
Certificate Type CB Test Report
Issuing NCB TÜV SÜD PSB Pte. Ltd., Singapore
Testing Laboratory TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Test Scheme CB Scheme
TRF Template IECEE OD-2020-F1:2021, Ed.1.4
TRF Form No. IEC62133_2C
TRF Originator DEKRA Certification B.V.
Master TRF Date 2022-07-01

Product Information

The tested product is the lithium-ion battery pack integrated into the ETENWOLF P200 electric ball pump, a portable inflation tool designed for sports balls and similar applications. The battery pack provides the power source for the cordless, rechargeable pump system.

Field Details
Test Item Description Lithium-ion Battery Pack
Trade Mark N/A
Model / Type Reference 1S1P-2000
Rated Voltage 3.7 V d.c.
Rated Capacity 2000 mAh
Configuration 1 Series × 1 Parallel (1S1P)
Applicant Guangdong Bestek Technology Co., LTD.
Applicant Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, 517099 Heyuan City, Guangdong, People’s Republic of China
Manufacturer Same as applicant

Key Details

The CB Test Report covers safety testing performed in accordance with IEC 62133-2:2017 and its Amendment 1 (2021). Tests were conducted on sample quantities specified in Table 1 of the standard. The report includes two attachments: national differences for the Republic of Korea (3 pages) and photo documentation (4 pages).

Test Clauses Performed

Clause Test Name Scope
7.2.2 Case stress at high ambient temperature Battery
7.3.2 External short circuit Battery

Note: Additional test clauses were present in the full 24-page report but were truncated in the extracted source text. The above represents all clauses confirmed in the available extraction.

Testing Personnel

Role Name Function
Tested by West Li Project Handler
Approved by Kevin Zou Project Reviewer

Testing Location

Building A2, Jin’ao Industrial Park, No.150, Jingfang Road, Fuhai, Bao’an District, Shenzhen, Guangdong 518103, China.

Report Attachments

  • Attachment No. 1: 3 pages — Republic of Korea National Differences
  • Attachment No. 2: 4 pages — Photo Documentation

Standards & Compliance

The battery pack was tested against the following international and amended standards under the IECEE CB Scheme:

Standard Title Edition / Amendment
IEC 62133-2:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications – Part 2: Lithium systems Edition 1, 2017
IEC 62133-2:2017/AMD1:2021 Amendment 1 to IEC 62133-2:2017 Amendment 1, 2021

The test procedure followed was the CB Scheme procedure as defined by IECEE. No non-standard test methods were applied (N/A). The TRF template used was IECEE OD-2020-F1:2021, Ed.1.4, based on the master TRF dated 2022-07-01, originated by DEKRA Certification B.V.

Additionally, Republic of Korea national differences were evaluated and documented in Attachment No. 1, indicating that this CB report supports KC certification applications.

Validity & Certification Body

This CB Test Report (No. 211-282250758-000) is valid only when appended to a CB Test Certificate issued by an accredited NCB in accordance with IECEE 02. The report is not valid as a standalone CB Test Report unless signed by an approved IECEE Testing Laboratory.

Field Details
Issuing NCB TÜV SÜD PSB Pte. Ltd.
NCB Address 15 International Business Park, TÜV SÜD@IBP, Singapore 609937
Testing Laboratory TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Lab Address Building A2, Jin’ao Industrial Park, No.150, Jingfang Road, Fuhai, Bao’an District, Shenzhen, Guangdong 518103, China
Date of Issue 2025-10-11
Report Number 211-282250758-000
Reproducibility Report shall not be reproduced except in full without written approval of the Issuing NCB
Authenticity Verification Contact TÜV SÜD PSB Pte. Ltd., Singapore

The authenticity of this test report and its contents can be verified by contacting the NCB responsible for this report: TÜV SÜD PSB Pte. Ltd. in Singapore. The test results presented relate only to the specific object tested and cannot be generalised to other products or batches.

Frequently Asked Questions

What is a CB Test Report and why does it matter for the ETENWOLF P200?

A CB Test Report is an internationally recognised safety assessment document issued under the IECEE CB Scheme. For the ETENWOLF P200, Report No. 211-282250758-000 confirms that its 3.7V 2000mAh lithium-ion battery pack (model 1S1P-2000) passed the safety tests required by IEC 62133-2:2017 and its Amendment 1:2021. This facilitates market access in multiple countries by allowing national certification bodies to issue local certificates based on the CB report.

Which standard was used to test the ETENWOLF P200 battery pack?

The battery pack was tested against IEC 62133-2:2017 including IEC 62133-2:2017/AMD1:2021. This standard specifies safety requirements for portable sealed secondary lithium cells and battery packs used in portable applications, covering hazards such as short circuits, thermal stress, and mechanical integrity.

Does the CB report cover Korea (KC) certification requirements?

Yes. Attachment No. 1 of Report No. 211-282250758-000 contains 3 pages of Republic of Korea national differences, which means the report documents compliance deviations or confirmations relevant to Korean KC certification. Applicants can use this report to support a KC certification application for the ETENWOLF P200 battery pack.

Who conducted and approved the safety tests for the ETENWOLF P200 battery?

The tests were conducted at TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch located in Shenzhen, Guangdong, China. The tests were performed by West Li (Project Handler) and approved by Kevin Zou (Project Reviewer). The report was issued under the responsibility of the NCB TÜV SÜD PSB Pte. Ltd. in Singapore.

Related Documents

The following certification and compliance documents are typically associated with a portable lithium-ion battery-powered inflation tool such as the ETENWOLF P200:

  • UN 38.3 Transport Test Report — Required for air and ground shipment of lithium battery packs; covers altitude simulation, thermal test, vibration, shock, external short circuit, impact, overcharge, and forced discharge per UN Manual of Tests and Criteria, Part III, Section 38.3.
  • CE Declaration of Conformity — Required for sale in the European Economic Area; covers applicable EU directives such as the Battery Directive and Low Voltage Directive.
  • FCC ID Certification — Required for sale in the United States if the product contains radio-frequency components or wireless charging; issued by the Federal Communications Commission.
  • KC Mark Certificate — Required for sale in the Republic of Korea; supported by the national differences documented in Attachment No. 1 of this CB report.
  • RoHS Compliance Report — Confirms restriction of hazardous substances in electrical and electronic equipment per EU RoHS Directive 2011/65/EU.
  • REACH SVHC Declaration — Confirms that the product does not contain substances of very high concern above threshold limits per EU REACH Regulation (EC) No 1907/2006.
  • IEC 62133-1 CB Report — Equivalent CB report for nickel-based secondary cell systems, not applicable here but relevant for product line comparisons.

Document Pages

ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 1
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 2
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 3
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 4
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 5
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 6
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 7
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 8
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 9
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 10
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 11
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 12
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 13
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 14
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 15
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 16
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 17
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 18
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 19
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 20
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 21
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 22
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 23
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 24
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 25
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 26
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 27
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 28
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 29
ETENWOLF P200 IEC 62133-2 CB Test Report 211-282250758-000 — Page 30