ETENWOLF T200 Tire Pressure Detector — REACH SVHC Test Report WTH25X07183015C

Document Overview

Document Overview This page presents the verified results of a REACH SVHC (Substances of Very High Concern) Test Report issued for the ETENWOLF T200 tire pressure detector. The report was prepared by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory, under Report…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
Pressure & Measurement

Document Overview

This page presents the verified results of a REACH SVHC (Substances of Very High Concern) Test Report issued for the ETENWOLF T200 tire pressure detector. The report was prepared by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory, under Report Number WTH25X07183015C.

The test scope covers the determination of 250 Substances of Very High Concern (SVHC) and 2 potential substances as listed on the European Chemicals Agency (ECHA) Candidate List, in accordance with European Commission Regulation (EC) No 1907/2006 (REACH).

  • Report Number: WTH25X07183015C
  • Document Type: REACH SVHC Test Report
  • Issuing Body: Waltek Testing Group (Shenzhen) Co., Ltd.
  • Sample Receipt Date: 2025-07-13
  • Testing Period: 2025-07-13 to 2025-07-18
  • Date of Issue: 2025-07-25
  • Regulatory Basis: EC No 1907/2006 (REACH), ECHA Candidate List

Product Information

The ETENWOLF T200 is a tire pressure detector designed for vehicle safety monitoring. It is manufactured and supplied by Guangdong Bestek Technology Co., Ltd., the applicant on record for this certification.

  • Sample Name: Tire Pressure Detector
  • Model Number: T200
  • Reference Model Number: N/A
  • Brand: N/A (as filed)
  • Applicant / Manufacturer: Guangdong Bestek Technology Co., Ltd.
  • Manufacturer Address: No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China

The product was disassembled into 30 individual material samples spanning both metal and non-metal component categories, each tested separately to ensure comprehensive SVHC coverage across all constituent materials.

Key Details

The test was conducted on 30 material samples grouped into two test groups: T01 (Metal components) and T02 (Non-metal components). All results were reported as ND (Not Detected), meaning concentrations were below the respective reporting limits (RL), well under the 0.1% w/w regulatory threshold.

Overall Test Results

Group No. Substance Scope Result (%,w/w)
T01 250 SVHC + 2 potential substances (Metal samples) ND
T02 250 SVHC + 2 potential substances (Non-metal samples) ND

T01 — Metal Component Samples

Sample No. Description Material Description
4 Metal Silvery metal sheet
5 Metal Silvery metal spring
6 Metal Silvery metal screw
7 Metal Silvery metal screw
10 Metal Silvery metal body
11 Metal Silvery square metal body (switch)
13 Metal Silvery metal sheet (switch)
15 Metal Silvery metal PIN (switch)
17 Metal Silvery metal PIN
22 Metal Coppery metal coil (Inductance)
27 Metal Solder

T02 — Non-Metal Component Samples

Sample No. Description Material Description
1 Nonmetal Black plastic shell
2 Nonmetal Black plastic
3 Nonmetal Black w/transparent plastic sheet
8 Nonmetal Black plastic film
9 Nonmetal White plastic
12 Nonmetal Black plastic button (switch)
14 Nonmetal Black plastic base (switch)
16 Nonmetal Transparent LED body
18 Nonmetal Black triode SMD
19 Nonmetal Black cladding PCB board (tested as a whole)
20 Nonmetal Brown capacitor SMD
21 Nonmetal Gray solid material (Inductance)
23 Nonmetal Black IC SMD
24 Nonmetal Black resistance SMD
25 Nonmetal Black IC SMD
26 Nonmetal Yellow LED
28 Nonmetal Black plastic
29 Nonmetal Black rubber tube
30 Nonmetal Black rubber ring

ND = Not Detected. Concentration is less than the reporting limit (RL). The 0.1% w/w threshold applies per Article 7 of Regulation (EC) No 1907/2006.

Standards & Compliance

The REACH SVHC evaluation for the T200 was conducted using a combination of in-house and internationally recognized analytical test methods. The regulatory framework governing this test is European Commission Regulation (EC) No 1907/2006 (REACH), specifically targeting substances identified under Article 57 and listed via Article 59(1) on the ECHA Candidate List.

Test Methods Applied

Method Scope
EPA 3550C:2007 Ultrasonic extraction for semi-volatile organic compounds
US EPA 8270D:2018 GC/MS analysis of semi-volatile organic compounds
US EPA 3052:1996 Microwave-assisted acid digestion of siliceous and organically-based matrices
US EPA 3050B:1996 Acid digestion of sediments, sludges, and soils
US EPA 6010D:2018 Inductively coupled plasma — optical emission spectrometry (ICP-OES)
BS EN ISO 14362-1:2017 Determination of aromatic amines from azo colorants — Part 1
BS EN ISO 14362-3:2017 Determination of aromatic amines from azo colorants — Part 3
ISO 17234-1:2020 Chemical tests for leather — determination of certain azo colorants
ISO 17234-2:2011 Chemical tests for leather — determination of 4-aminoazobenzene
ISO 17353:2004 Water quality — determination of selected organotin compounds
AfPS GS 2019:01 PAK Testing for polycyclic aromatic hydrocarbons (PAH)

The SVHC candidate list tested against is the ECHA Candidate List, which at the time of testing comprised 250 SVHC substances and 2 potential substances. The measurement workflow followed: Sampling → Acid digestion and solvent extraction → Instrumental analysis → Data reporting.

Validity & Certification Body

This test report was issued by Waltek Testing Group (Shenzhen) Co., Ltd., a professional third-party testing and certification body headquartered in Shenzhen, China. The report is signed by Hugo Chen on behalf of Waltek Testing Group.

  • Report Number: WTH25X07183015C
  • Date of Issue: 2025-07-25
  • Testing Laboratory: Waltek Testing Group (Shenzhen) Co., Ltd.
  • Laboratory Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China
  • Tel: +86-755-33663308
  • Fax: +86-755-33663309
  • Email: [email protected]
  • Website: http://www.waltek.com.cn
  • Signed By: Hugo Chen, Waltek Testing Group (Shenzhen) Co., Ltd.

REACH SVHC compliance is an ongoing obligation. Suppliers are required to re-evaluate their products whenever the ECHA Candidate List is updated. Customers and consumers may request SVHC substance information within 45 days of their request, per EU/EEA regulation effective from 28 October 2008.

Frequently Asked Questions

What does the REACH SVHC test result mean for the T200?

All 250 SVHC substances and 2 potential substances were found to be Not Detected (ND) in every material sample of the T200. This means their concentrations are below the respective reporting limits, which are all well under the regulatory threshold of 0.1% weight by weight (w/w) required by REACH Regulation (EC) No 1907/2006. The product is therefore compliant for sale in the EU and EEA.

How many components were tested in the T200?

A total of 30 individual material samples were taken from the T200, covering all major material categories. These were split into Group T01 (11 metal components including screws, springs, metal sheets, solder, and inductance coils) and Group T02 (19 non-metal components including plastic shells, PCB board, SMD components, LED bodies, and rubber parts).

Which laboratory conducted the REACH SVHC testing?

The test was conducted by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory based in Shenzhen, Guangdong, China. The report number is WTH25X07183015C, issued on 2025-07-25.

Can consumers request SVHC substance information for the T200?

Yes. Under EU/EEA regulations in force since 28 October 2008, any consumer may request information about SVHC substances present above 0.1% w/w in an article. The supplier must respond within 45 days. In the case of the T200, all SVHC concentrations are below the 0.1% threshold, so no notification obligation is triggered under Article 7(2) of REACH.

Related Documents

The following certification and compliance documents are relevant to the ETENWOLF T200 tire pressure detector and are recommended to be reviewed alongside this REACH SVHC report for full regulatory due diligence:

  • RoHS Test Report — Restriction of Hazardous Substances testing covering the 10 restricted substances under EU Directive 2011/65/EU (RoHS 2), including lead, mercury, cadmium, and hexavalent chromium.
  • CE Declaration of Conformity — Formal declaration that the T200 meets all applicable CE marking requirements for the EU market, covering EMC and relevant product safety directives.
  • FCC Test Report — Radio frequency compliance testing under FCC regulations for market access in the United States.
  • UN38.3 Test Report — If the T200 contains a lithium battery, a UN38.3 transport safety test report is required for air and sea freight compliance.
  • KC CertificationKC Mark conformity certification for the Korean market, covering electrical safety and EMC requirements.
  • ISO 9001 Quality Management Certificate — Manufacturing quality system certification demonstrating consistent production standards at the Guangdong Bestek Technology Co., Ltd. facility.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22