Document Overview
Key Findings The ETENWOLF T500 tire pressure gauge completed a 6-face drop test from 100 cm with all functional and accuracy checks passing after impact; the result is classified as Reference. Product: T500 Tire Pressure Gauge Drop Height: 100 cm Drop Faces: 6 (one drop…
- Document type
- Test Report
- Prepared by
- Kevin Marshall
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF T500 tire pressure gauge completed a 6-face drop test from 100 cm with all functional and accuracy checks passing after impact; the result is classified as Reference.
- Product: T500 Tire Pressure Gauge
- Drop Height: 100 cm
- Drop Faces: 6 (one drop per face, 6 total)
- Sample Quantity: 2 PCS
- Environment: 22 °C, 55% RH
- Post-Test Appearance: Normal
- Post-Test Function & Accuracy: Pass
- Verdict: Reference
Test Overview
| Field | Details |
|---|---|
| Test Type | Drop Test (Mechanical Reliability) |
| Report Title | Drop Test Report |
| Report No. | 2024080101 |
| Page | 1 |
| Date | 2024-08-01 |
| Product Name | T500 Tire Pressure Gauge |
| Manufacturer | BTK |
| Surface Treatment | Not specified |
| Sample Quantity | 2 PCS |
| Test Reason | New Product |
| Test Objective | Evaluate the reliability of the finished product by simulating its anti-drop impact capability. |
| Laboratory Temperature | 22 °C |
| Laboratory Humidity | 55% RH |
| Sample Weight | Not recorded |
Test Equipment & Setup
| Parameter | Details |
|---|---|
| Instrument Name | Single-Arm Drop Testing Machine |
| Test Class / Level | Not specified |
| Drop Height | 100 cm |
| Number of Drops | 6 faces (6 drops total) |
| Test Requirement | After testing, product appearance and function must be normal. |
Test Procedure
- Pre-Test: Record laboratory environment (temperature 22 °C, humidity 55% RH). Confirm sample quantity (2 PCS) and document sample weight if applicable.
- Pre-Test Inspection: Photograph and inspect each sample for appearance and functional integrity before any drop.
- Drop Execution: Using the single-arm drop testing machine, drop each sample from a height of 100 cm onto each of the 6 faces (Drop 1 through Drop 6) in sequence.
- Inter-Drop Inspection: Visually inspect the sample after each individual drop and note any deformation, cracking, or component separation.
- Post-Test Appearance Check: Photograph all samples after all 6 drops and compare with pre-test images.
- Post-Test Functional & Accuracy Check: Verify that all product functions operate normally and that measurement accuracy meets specification.
- Result Recording: Document internal packaging arrangement, appearance condition, functional status, and accuracy status.
Acceptance Criteria: Product appearance and function must remain normal after all 6 drops from 100 cm. The verdict options are Pass, Fail, or Reference.
Test Data & Results
| Stage | Drop No. | Face / Orientation | Appearance After Drop | Function & Accuracy |
|---|---|---|---|---|
| Pre-Test | — | — | Normal (photographed before test) | Normal |
| During Test | Drop 1 | Face 1 | Normal | Pass |
| During Test | Drop 2 | Face 2 | Normal | Pass |
| During Test | Drop 3 | Face 3 | Normal | Pass |
| During Test | Drop 4 | Face 4 | Normal | Pass |
| During Test | Drop 5 | Face 5 | Normal | Pass |
| During Test | Drop 6 | Face 6 | Normal | Pass |
| Post-Test | — | — | Normal | Function & Accuracy OK |
Observations: After all 6 drops, the items and accessories inside the product packaging were found displaced from their original positions. However, the product itself passed both functional and accuracy checks. Appearance remained normal post-test.
Conclusion
| Item | Details |
|---|---|
| Verdict | Reference |
| Standard / Test Condition | 100 cm drop height, 6 faces, single-arm drop testing machine |
| Samples Tested | 2 PCS |
| Appearance Result | Normal after all 6 drops |
| Function & Accuracy Result | Pass |
| Packaging Observation | Internal product and accessories were displaced after drops |
| Overall Assessment | Product function and accuracy intact; result logged as Reference due to internal packaging displacement |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | — |
| Review / Check (审查) | Mai Shaoqiang |
| Tester (试验人) | Zhang Ronggui |
| Form Number | BTK-R-Q-087A/1 |
Frequently Asked Questions
What does a "Reference" verdict mean in the ETENWOLF T500 drop test?
A Reference verdict means the product passed all functional and accuracy checks after the drop test, but an observation was noted — in this case, internal packaging components were displaced after the 6-face drops. The product is not classified as a failure, but the result is recorded for engineering review rather than as a clean Pass.
From what height was the T500 tire pressure gauge drop tested?
The T500 was drop tested from a height of 100 cm using a single-arm drop testing machine. The test covered all 6 faces of the unit, for a total of 6 individual drops.
Did the T500 tire pressure gauge maintain accuracy after the drop test?
Yes. After all 6 drops from 100 cm, the T500’s measurement accuracy and all product functions were confirmed normal. The appearance was also intact, with no cracking or deformation recorded.
How many samples were tested in the T500 drop test?
Two samples (2 PCS) of the T500 tire pressure gauge were used for this drop test, conducted under laboratory conditions of 22 °C and 55% RH.
Related Products
Explore the full ETENWOLF T500 product page and related test documentation:
Other test reports from the same test batch (T500, August 2024):
- Sheet2 — Additional T500 Test Report (same Excel workbook, August 2024)