Document Overview
Key Findings The ETENWOLF T600 Digital Tire Pressure Gauge successfully passed the ISTA-2A transport vibration test across all three axes (X, Y, Z) with no appearance abnormalities and full functional integrity confirmed post-test. Product: T600 Digital Tire Pressure Gauge Standard: ISTA-2A Test Mode: Random vibration,…
- Document type
- Test Report
- Prepared by
- Kevin Marshall
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF T600 Digital Tire Pressure Gauge successfully passed the ISTA-2A transport vibration test across all three axes (X, Y, Z) with no appearance abnormalities and full functional integrity confirmed post-test.
- Product: T600 Digital Tire Pressure Gauge
- Standard: ISTA-2A
- Test Mode: Random vibration, 3-axis (X, Y, Z)
- Duration: 1 hour
- Frequency: 4 Hz
- Amplitude: 25.4 mm
- Speed (CMP): 240 G
- Sample Quantity: 3 PCS
- Verdict: PASS — no appearance defects, no functional failures
Test Overview
| Field | Details |
|---|---|
| Report Title | Vibration Test Report |
| Report No. | 2025072901 |
| Page | 1 |
| Date | 2025-07-29 |
| Product Name | T600 Digital Tire Pressure Gauge (T600-胎压计) |
| Manufacturer | BTK |
| Surface Treatment | / |
| Sample Quantity | 3 PCS |
| Test Class / Standard | ISTA-2A |
| Test Reason | New Product |
| Test Objective | To verify the resistance of the sample under transportation and use-environment vibration conditions |
| Laboratory Temperature | 30 °C |
| Laboratory Humidity | 55% RH |
Test Equipment & Setup
| Parameter | Value |
|---|---|
| Instrument Name | Vibration Testing Machine |
| Test Mode | Random Mode |
| Test Duration | 1 H |
| Vibration Direction | Random — X, Y, Z |
| Vibration Frequency | 4 Hz |
| Test Speed (CMP) | 240 G |
| Vibration Amplitude | 25.4 mm |
Test Procedure
- Pre-test: Verify sample placement and vibration fixture setup (振动摆放 / vibration control chart confirmed).
- Pre-test functional check: Perform high-pressure and low-pressure functionality test — result OK (高低压功能性测试OK).
- Conditioning: Record laboratory environment — temperature 30 °C, humidity 55% RH.
- Vibration execution: Mount 3 PCS T600 samples on the vibration testing machine. Apply random-mode vibration at 4 Hz, 25.4 mm amplitude, 240 G CMP for 1 hour continuously across X, Y, and Z axes.
- Post-test inspection: Visually inspect all samples for appearance abnormalities (cracks, deformation, surface damage).
- Post-test functional check: Re-perform high/low pressure functionality test on all samples.
- Acceptance criteria: No appearance defects; all functional tests pass; no failures under simulated transport vibration conditions.
Test Data & Results
| Check Point | Pre-Test Result | Post-Test Result |
|---|---|---|
| High/Low Pressure Functionality | OK | OK |
| Appearance — Cracks / Deformation | Normal | No abnormality |
| Functional Failure | None | None |
Test Result Statement: Samples passed the simulated transport vibration test. No appearance abnormalities were observed. No functional failures occurred. All functionality tests confirmed OK after vibration exposure.
Judgment: ■ Pass □ Fail □ Reference
Conclusion
| Item | Details |
|---|---|
| Product | T600 Digital Tire Pressure Gauge |
| Applied Standard | ISTA-2A |
| Test Conditions | Random vibration, 4 Hz, 25.4 mm amplitude, 240 G CMP, 1 H, X/Y/Z axes; 30 °C / 55% RH |
| Samples Tested | 3 PCS |
| Appearance Result | No abnormalities detected |
| Functional Result | All functions intact — no failures |
| Overall Verdict | PASS |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number | BTK-R-Q-087A/1 |
Frequently Asked Questions
What vibration standard was used for the ETENWOLF T600 drop and transport test?
The T600 was tested to the ISTA-2A standard, which simulates the vibration and shock hazards a packaged product may encounter during distribution. The test used random-mode vibration across three axes (X, Y, Z) at 4 Hz frequency and 25.4 mm amplitude for one hour.
Did the ETENWOLF T600 pass the transport vibration test?
Yes. All three T600 samples passed the ISTA-2A transport vibration test. Post-test inspection confirmed no appearance abnormalities and no functional failures. High and low pressure reading functions remained fully operational after the one-hour vibration session.
What test conditions were applied during the T600 vibration test?
The test was conducted at 30 °C and 55% RH. The vibration testing machine operated in random mode at 4 Hz, with an amplitude of 25.4 mm and a test speed of 240 G CMP. All three spatial axes (X, Y, Z) were covered during the one-hour test duration.
How many T600 samples were tested and who approved the report?
Three (3) PCS of the T600 Digital Tire Pressure Gauge were tested. The report was approved by Mai Shaoqiang, reviewed by Zhang Ronggui, and the test was conducted by Li Guanghua. The form number is BTK-R-Q-087A/1, dated 2025-07-29.