ETENWOLF T600 Digital Tire Pressure Gauge Transport Vibration Test Report (ISTA-2A, Random, 3-Axis)

Document Overview

Key Findings The ETENWOLF T600 Digital Tire Pressure Gauge successfully passed the ISTA-2A transport vibration test across all three axes (X, Y, Z) with no appearance abnormalities and full functional integrity confirmed post-test. Product: T600 Digital Tire Pressure Gauge Standard: ISTA-2A Test Mode: Random vibration,…

Document type
Test Report
Prepared by
Kevin Marshall
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

The ETENWOLF T600 Digital Tire Pressure Gauge successfully passed the ISTA-2A transport vibration test across all three axes (X, Y, Z) with no appearance abnormalities and full functional integrity confirmed post-test.

  • Product: T600 Digital Tire Pressure Gauge
  • Standard: ISTA-2A
  • Test Mode: Random vibration, 3-axis (X, Y, Z)
  • Duration: 1 hour
  • Frequency: 4 Hz
  • Amplitude: 25.4 mm
  • Speed (CMP): 240 G
  • Sample Quantity: 3 PCS
  • Verdict: PASS — no appearance defects, no functional failures

Test Overview

Field Details
Report Title Vibration Test Report
Report No. 2025072901
Page 1
Date 2025-07-29
Product Name T600 Digital Tire Pressure Gauge (T600-胎压计)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 PCS
Test Class / Standard ISTA-2A
Test Reason New Product
Test Objective To verify the resistance of the sample under transportation and use-environment vibration conditions
Laboratory Temperature 30 °C
Laboratory Humidity 55% RH

Test Equipment & Setup

Parameter Value
Instrument Name Vibration Testing Machine
Test Mode Random Mode
Test Duration 1 H
Vibration Direction Random — X, Y, Z
Vibration Frequency 4 Hz
Test Speed (CMP) 240 G
Vibration Amplitude 25.4 mm

Test Procedure

  1. Pre-test: Verify sample placement and vibration fixture setup (振动摆放 / vibration control chart confirmed).
  2. Pre-test functional check: Perform high-pressure and low-pressure functionality test — result OK (高低压功能性测试OK).
  3. Conditioning: Record laboratory environment — temperature 30 °C, humidity 55% RH.
  4. Vibration execution: Mount 3 PCS T600 samples on the vibration testing machine. Apply random-mode vibration at 4 Hz, 25.4 mm amplitude, 240 G CMP for 1 hour continuously across X, Y, and Z axes.
  5. Post-test inspection: Visually inspect all samples for appearance abnormalities (cracks, deformation, surface damage).
  6. Post-test functional check: Re-perform high/low pressure functionality test on all samples.
  7. Acceptance criteria: No appearance defects; all functional tests pass; no failures under simulated transport vibration conditions.

Test Data & Results

Check Point Pre-Test Result Post-Test Result
High/Low Pressure Functionality OK OK
Appearance — Cracks / Deformation Normal No abnormality
Functional Failure None None

Test Result Statement: Samples passed the simulated transport vibration test. No appearance abnormalities were observed. No functional failures occurred. All functionality tests confirmed OK after vibration exposure.

Judgment: ■ Pass  □ Fail  □ Reference

Conclusion

Item Details
Product T600 Digital Tire Pressure Gauge
Applied Standard ISTA-2A
Test Conditions Random vibration, 4 Hz, 25.4 mm amplitude, 240 G CMP, 1 H, X/Y/Z axes; 30 °C / 55% RH
Samples Tested 3 PCS
Appearance Result No abnormalities detected
Functional Result All functions intact — no failures
Overall Verdict PASS

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Review (审查) Zhang Ronggui
Tester (试验人) Li Guanghua
Form Number BTK-R-Q-087A/1

Frequently Asked Questions

What vibration standard was used for the ETENWOLF T600 drop and transport test?

The T600 was tested to the ISTA-2A standard, which simulates the vibration and shock hazards a packaged product may encounter during distribution. The test used random-mode vibration across three axes (X, Y, Z) at 4 Hz frequency and 25.4 mm amplitude for one hour.

Did the ETENWOLF T600 pass the transport vibration test?

Yes. All three T600 samples passed the ISTA-2A transport vibration test. Post-test inspection confirmed no appearance abnormalities and no functional failures. High and low pressure reading functions remained fully operational after the one-hour vibration session.

What test conditions were applied during the T600 vibration test?

The test was conducted at 30 °C and 55% RH. The vibration testing machine operated in random mode at 4 Hz, with an amplitude of 25.4 mm and a test speed of 240 G CMP. All three spatial axes (X, Y, Z) were covered during the one-hour test duration.

How many T600 samples were tested and who approved the report?

Three (3) PCS of the T600 Digital Tire Pressure Gauge were tested. The report was approved by Mai Shaoqiang, reviewed by Zhang Ronggui, and the test was conducted by Li Guanghua. The form number is BTK-R-Q-087A/1, dated 2025-07-29.

Related Products